Home
>
Panasonic
>
Remote Control
>
Panasonic Multi Format Live Switcher Av Hs300g Operating Instructions
Panasonic Multi Format Live Switcher Av Hs300g Operating Instructions
Here you can view all the pages of manual Panasonic Multi Format Live Switcher Av Hs300g Operating Instructions. The Panasonic manuals for Remote Control are available online for free. You can easily download all the documents as PDF.
Page 41
41 3. Setup 3-9. Status displays The statuses can be displayed. 1 Press the [FUNC] switch to light its indicator, and then press the [SETUP] switch to display the SETUP menu. 2 Turn [F1] to display the STATS menu. ALM (alarm) : Indicates a fan and/or power supply alarm. FAN Fan alarm POWR Power supply alarm F, P Fan alarm and power supply alarm NO No alarm information OPT (option) : Indicates whether or not an optional board is provided. ANLG The HD analog board has been inserted....
Page 42
4 4. Setting menu table A setting is entered when an item displayed () is selected and then the [F1], [F], [F3] or [F4] switch is pressed. (It will not be entered unless the switch is pressed.) MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. TIMEBKGDParameterTRANSTIMEUNIT 1/ Setting range0 to 13s0 to 999fF SEC Default value—30fSEC KEYParameterTRANSTIMEUNIT / Setting range0 to 13s0 to 999fF SEC Default...
Page 43
43 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. CBGDUSR4(*)ParameterHUESATLUM 5/5Setting range0 to 3590 to 1000 to 108 Default value000 KEYKEYParameterTYPEINVPVW 1/7Setting rangeSELF LIN ON OFF ON OFF AUTO Default valueLINOFFAUTO K-ADJParameterCLIPGAINDENS /7 Setting range0 to 108 0 to 000 to 100 Default value0100100 FILLParameterTYPECOLR 3/7 KEY-F Link from switch Setting rangeBUS COLR WHT, YLW, CYN GRN, MGT,...
Page 44
44 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. EDGEUSR3(*)ParameterHUESATLUM 4/5Setting range0 to 3590 to 1000 to 108 Default value501009 USR4(*)ParameterHUESATLUM 5/5Setting range0 to 3590 to 1000 to 108 Default value000 MEMPSMEMParameterMODENO. 1/3Setting rangeSTOR RECL CLR 1 to 10EXEC () Default valueSTOR1— PSMEMParameterXPT—— /3 Setting rangeDSBL ENBL —— Default valueDSBL—— FMEMParameterSIGMEMSTOR 3/3Setting...
Page 45
45 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. SETUPIN1–5ParameterSIGMODEGAIN 1/15Setting rangeIN1 to 5SDI ANLG –30 to 30 Default valueIN1 to 5SDI ANLG — 0 DVIINParameterMODESCAL— /15 Setting rangeDIG ANLG NORM FULL — Default valueDIGNORM— FSParameterSIGFS— 3/15Setting rangeIN1 to 5ON OFF — Default valueIN1 to 5ON— FORMTParameterMODE—— 4/15Setting range1080/59i 1080/50i 70/59p 70/50p 480/59i 576/50i —EXEC ()...
Page 46
46 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. SETUPSYSParameterBLVANCBB 1/15 Setting rangeON OFF ON OFF 0 7.5 Default valueONOFF7.5 DVIPHParameterCKPHHPOSVPOS 13/15Setting range–16 to 15–100 to 100–100 to 100 Default value000 INITParameterINIT—— 14/15Setting rangeEXEC () STATSParameterALMOPTVER 15/15Display onlyFAN POWR F, P NO ANLG NO Version number * The same USR1 to USR4 parameters are used for the WIPE menu, CBGD...
Page 47
47 5. Image transmission functions This unit comes with a function for transmitting still images from the host computer to the unit via Ethernet and a function for importing still images from the unit into the host computer. The image transmission program must be installed in the host computer from the CD-ROM supplied in order to use these functions. For details on installation, refer to “How to install the program”. Specifications Run the image transmission program (HS300 Tool) in a host computer...
Page 48
48 5. Image transmission functions How to install the program This section describes how to install the image transmission program (HS300 Tool). Windows XP is used as the host computer’s operating system in the example given here. 1. Insert the CD-ROM supplied with the unit into the CD-ROM drive of the host computer in which the program will be installed. (Here, E: will serve as the name of this drive for example.) . Execute the setup program (E:\HS300TOOL\ENG\SETUP.EXE). 3. The installer...
Page 49
49 5. Image transmission functions Operation This section describes how to operate the image transmission program (HS300 Tool). On the Start menu of Windows, select [Programs] [Panasonic] [AV-HS300Tool] [HS300Tool]. The main screen now appears. Click the [CLOSE] button. Set the unit’s IP address in the IP Address setting box.
Page 50
50 5. Image transmission functions 1. Select the mode. Check that “To HS300” appears in the [Mode] field. If “From HS300” appears instead, click the Mode button so that “To HS300” appears. . When the [Select Image] button is clicked, the file selection dialog box appears on the screen. Select the image file to be transmitted, and click [OK]. The image is now displayed in the image display area, and its horizontal and vertical dimensions appear in the [Width] and [Height] fields at...