Have a look at the manual Panasonic Multi Format Live Switcher Av Hs300g Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
41 3. Setup 3-9. Status displays The statuses can be displayed. 1 Press the [FUNC] switch to light its indicator, and then press the [SETUP] switch to display the SETUP menu. 2 Turn [F1] to display the STATS menu. ALM (alarm) : Indicates a fan and/or power supply alarm. FAN Fan alarm POWR Power supply alarm F, P Fan alarm and power supply alarm NO No alarm information OPT (option) : Indicates whether or not an optional board is provided. ANLG The HD analog board has been inserted. NO The HD analog board has not been inserted. VER (version) : Indicates the software version. /01083 1 /0 4554 -. / 015 /-( 7&3 3-10. Initialization All the settings except the preset memory can be returned to the factory defaults. (When they are returned, the images in the frame memory will also be initialized.) 1 Press the [FUNC] switch to light its indicator, and then press the [SETUP] switch to display the SETUP menu. 2 Turn [F1] to display the INIT menu. 3 Press [F] to initialize the settings. The “INIT?” message appears. 4 To initialize the settings, turn [F] to select YES, and then press the [F] switch. To cancel the initialization, turn [F] to select NO, and then press the [F] switch. */*5 */*5 &9&$ :&4 */*5 */*5 /0
4 4. Setting menu table A setting is entered when an item displayed () is selected and then the [F1], [F], [F3] or [F4] switch is pressed. (It will not be entered unless the switch is pressed.) MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. TIMEBKGDParameterTRANSTIMEUNIT 1/ Setting range0 to 13s0 to 999fF SEC Default value—30fSEC KEYParameterTRANSTIMEUNIT / Setting range0 to 13s0 to 999fF SEC Default value—30fSEC WIPEBODRParameterWIDTSOFTCOLR 1/5Setting range 0 to 55 0 to 55WHT, YLW, CYN GRN, MGT, RED BLE, BLK USR1 to 4 Default value00WHT USR1(*)ParameterHUESATLUM /5 Setting range0 to 3590 to 1000 to 108 Default value00100 USR2(*)ParameterHUESATLUM 3/5Setting range0 to 3590 to 1000 to 108 Default value3551007 USR3(*)ParameterHUESATLUM 4/5Setting range0 to 3590 to 1000 to 108 Default value50100 9 USR4(*)ParameterHUESATLUM 5/5Setting range0 to 3590 to 1000 to 108 Default value000 CBGDCBGDParameterCOLR—— 1/5Setting rangeWHT, YLW, CYN GRN, MGT, RED BLE, BLK USR1 to 4 —— Default valueWHT USR1(*)ParameterHUESATLUM /5 Setting range0 to 3590 to 1000 to 108 Default value00100 USR2(*)ParameterHUESATLUM 3/5Setting range0 to 3590 to 1000 to 108 Default value3551007 USR3(*)ParameterHUESATLUM 4/5Setting range0 to 3590 to 1000 to 108 Default value50100 9
43 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. CBGDUSR4(*)ParameterHUESATLUM 5/5Setting range0 to 3590 to 1000 to 108 Default value000 KEYKEYParameterTYPEINVPVW 1/7Setting rangeSELF LIN ON OFF ON OFF AUTO Default valueLINOFFAUTO K-ADJParameterCLIPGAINDENS /7 Setting range0 to 108 0 to 000 to 100 Default value0100100 FILLParameterTYPECOLR 3/7 KEY-F Link from switch Setting rangeBUS COLR WHT, YLW, CYN GRN, MGT, RED BLE, BLK USR1 to 4 Default valueBUSBLE USR1(*)ParameterHUESATLUM 4/7Setting range0 to 3590 to 1000 to 108 Default value00100 USR2(*)ParameterHUESATLUM 5/7Setting range0 to 3590 to 1000 to 108 Default value3551007 USR3(*)ParameterHUESATLUM 6/7Setting range0 to 3590 to 1000 to 108 Default value50100 9 USR4(*)ParameterHUESATLUM 7/7Setting range0 to 3590 to 1000 to 108 Default value000 EDGEEDGEParameterTYPEWIDTCOLR 1/5Setting rangeOFF BODR DROP SHDW OUTL 0 to 4WHT, YLW, CYN GRN, MGT, RED BLE, BLK USR1 to 4 Default valueOFFYLW USR1(*)ParameterHUESATLUM /5 Setting range0 to 3590 to 1000 to 108 Default value00100 USR2(*)ParameterHUESATLUM 3/5Setting range0 to 3590 to 1000 to 108 Default value3551007 4. Setting menu table
44 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. EDGEUSR3(*)ParameterHUESATLUM 4/5Setting range0 to 3590 to 1000 to 108 Default value501009 USR4(*)ParameterHUESATLUM 5/5Setting range0 to 3590 to 1000 to 108 Default value000 MEMPSMEMParameterMODENO. 1/3Setting rangeSTOR RECL CLR 1 to 10EXEC () Default valueSTOR1— PSMEMParameterXPT—— /3 Setting rangeDSBL ENBL —— Default valueDSBL—— FMEMParameterSIGMEMSTOR 3/3Setting rangeAUXFMEMEXEC () Default value——— XPTXPTASDisplay only SIG: B 1 3 4 5 D XPT: 1 3 4 5 6 7 1/3 XPTASParameterXPTSIG— /3 Setting range1 to 7IN1 to 5, DVI BLK, CBGD, CBAR, FMEM — Default value1BLK— IN1— 3 IN— 4IN3— 5IN4— 6IN5— 7DVI— XPTSWParameterTIMG—— 3/3Setting rangeANY F1 F —— Default valueANY—— FRZFRZDisplay only FRZ: XPT: 1 3 4 5 6 7 1/ FRZParameterSIG—FRZ / Setting rangeIN1 to 5, DVI—Toggling between ON and OFF () Default valueIN1 to 5, DVI—OFF 4. Setting menu table
45 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. SETUPIN1–5ParameterSIGMODEGAIN 1/15Setting rangeIN1 to 5SDI ANLG –30 to 30 Default valueIN1 to 5SDI ANLG — 0 DVIINParameterMODESCAL— /15 Setting rangeDIG ANLG NORM FULL — Default valueDIGNORM— FSParameterSIGFS— 3/15Setting rangeIN1 to 5ON OFF — Default valueIN1 to 5ON— FORMTParameterMODE—— 4/15Setting range1080/59i 1080/50i 70/59p 70/50p 480/59i 576/50i —EXEC () Default value1080/59i—— REFParameterSYNCGL— 5/15Setting rangeBBST BBAD TRI INT — EXEC () Default valueBBST—— OUPHSParameterSYSHPHSVPHS 6/15Setting range0H 1H –130 to 1319 –100 to 100 Default value1H00 IPSetting rangeCursor movement 0 to 55 7/15Default value19.168.0.10 MASKSetting rangeCursor movement 0 to 55 8/15Default value55.55.55.0 GWSetting rangeCursor movement 0 to 55 9/15Default value0.0.0.0 MACDisplay only1-digit address display 10/15Default value— BUSParameterMODE—— 11/15Setting rangeA/B P/P (PGM/PST) —— Default valueP/P—— 4. Setting menu table
46 MenuSubmenuParameter 1Parameter 2Parameter 3 Turn F1 to select.Turn F to select.Turn F3 to select.Turn F4 to select. SETUPSYSParameterBLVANCBB 1/15 Setting rangeON OFF ON OFF 0 7.5 Default valueONOFF7.5 DVIPHParameterCKPHHPOSVPOS 13/15Setting range–16 to 15–100 to 100–100 to 100 Default value000 INITParameterINIT—— 14/15Setting rangeEXEC () STATSParameterALMOPTVER 15/15Display onlyFAN POWR F, P NO ANLG NO Version number * The same USR1 to USR4 parameters are used for the WIPE menu, CBGD menu, KEY menu and EDGE menu. 4. Setting menu table
47 5. Image transmission functions This unit comes with a function for transmitting still images from the host computer to the unit via Ethernet and a function for importing still images from the unit into the host computer. The image transmission program must be installed in the host computer from the CD-ROM supplied in order to use these functions. For details on installation, refer to “How to install the program”. Specifications Run the image transmission program (HS300 Tool) in a host computer which satisfies the following conditions.• Operating system: Windows 000 or Windows XP • Processor: Pentium III, 1 GHz or better recommended • RAM: 56 MB or more recommended • Hard disk drive: At least 50 MB of free memory • Ethernet: 10BASE-T or 100BASE-TX • Display: TrueColor (4 bit, 3 bit color), 800 600 dots or more The image formats supported include bitmap (bmp), JPEG (jpg), TIFF (tif), GIF (gif) and PNG (png). The image transmission program is equipped with a function for automatically converting images into the specified video format size. Connections Connect this unit to Ethernet using a twisted pair cable. Use a LAN crossover cable to connect the unit with the host computer directly. Use a LAN straight cable to connect to Ethernet using a hub or other equipment. For details on network setup such as IP addresses, refer to [3-7 Network settings]. Transmitting images uses network capacity which may result in other connected devices possibly being affected when connecting to Ethernet through a hub and other equipment. LAN crossover cable LAN straight cable HUB LAN straight cable
48 5. Image transmission functions How to install the program This section describes how to install the image transmission program (HS300 Tool). Windows XP is used as the host computer’s operating system in the example given here. 1. Insert the CD-ROM supplied with the unit into the CD-ROM drive of the host computer in which the program will be installed. (Here, E: will serve as the name of this drive for example.) . Execute the setup program (E:\HS300TOOL\ENG\SETUP.EXE). 3. The installer now starts up so follow its instructions to proceed. 4. The Setup Complete screen appears to indicate that installation is compl\ ete. Click [Finish] to close the window.
49 5. Image transmission functions Operation This section describes how to operate the image transmission program (HS300 Tool). On the Start menu of Windows, select [Programs] [Panasonic] [AV-HS300Tool] [HS300Tool]. The main screen now appears. Click the [CLOSE] button. Set the unit’s IP address in the IP Address setting box.
50 5. Image transmission functions 1. Select the mode. Check that “To HS300” appears in the [Mode] field. If “From HS300” appears instead, click the Mode button so that “To HS300” appears. . When the [Select Image] button is clicked, the file selection dialog box appears on the screen. Select the image file to be transmitted, and click [OK]. The image is now displayed in the image display area, and its horizontal and vertical dimensions appear in the [Width] and [Height] fields at the bottom right. 3. In the [Size] field, select the size of the image to be transmitted to the unit. HD1080 (190 1080), HD70 (180 70), SD NTSC (70 488) or SD PAL (70 576) can be selected as the size. If the image is in a different video format from the ones supported by the unit, the output will not be displayed properly. 4. In the [Aspect] field, select the scaling method. If the size of the image to be transmitted and the selected image differ, the image will be automatically scaled according to one of the following methods. Full : The size of the image is increased or reduced so that it fits the size selected in the [Size] field. If the aspect ratio of the image to be transmitted differs from that of the selected image, the ratio between the horizontal and vertical dimensions will be changed. Keep : The image is expanded or reduced while its original aspect ratio is kept unchanged. Any empty spaces in the image will appear black. 5. Click the [Send] button to transmit the image to the unit. 1. Select the mode. Check that “From HS300” appears in the [Mode] field. If “To HS300” appears instead, click the Mode button so that “From HS300” appears. . When the [Get] button is clicked, the image is imported from the unit. The image is now displayed in the image display area, and its horizontal and vertical dimensions appear in the Width and Height fields at the bottom right. 3. When the [Save Image] button is clicked, the file save dialog box appears on the screen. Select the image file to be transmitted, and click [Save].