Page 51
24lInstallation of Optional Cards2.4.1Location of Optional CardsThe location of the optional cards is shown below. PrecautionTo protect the printed circuit boards (P-boards) from static electricity, do not touch parts on the P-boards in the main unit and on the optional cards. Caller ID / DISA / FAX Detection Card Front Cover is open. 4-SLT Extension Expansion Card Connector Install Caller ID / DISA / FAX Detection Card, KX-TD30891. This card enables the Caller ID, DISA and FAX Detection features.Install...
Page 52
2.4.24-SLT Extension Expansion Card / Caller ID / DISA / FAX Detection Card Installation One 4-SLT Extension Expansion Card (XX-TD30870) and one Caller ID / DISA / FAX Detection Card (RX-TD3089 1) can be installed to the system. 4-SLT Extension Expansion Card adds four extra Device Port extensions to jacks 5 through 8, for a maximum of eight digital extensions plus eight single line device extensions. The basic configuration already supports digital proprietary telephones on jacks 5 through 8. Caller ID...
Page 53
2.4.24-SLT Extension Expansion Card / Caller ID / DISA / FAX Detection Card Installation 3. Attach the optional card to the marked connector. KX-TD3089 1 I KX-TD30870Do not touch this static sensitive area. 4. Tighten the screws. Screws 5. Replace the cover. 2-26Installation
Page 54
2.4.3. Doorphone and Door Opener Connection One doorphone (KX-T30865) and one door opener (user-supplied) can be installed. The maximum cable lengthThe maximum length of the doorphone and door opener line cord which connects to the system is as follows: Diameter of the lineMax. length Doorphone 22AWG180m (590 feet) 24AWG113m (370 feet) 26AWG70m (230 feet) Door Opener22AWG180m (590 feet) Installing the Doorphone1. Loosen the screw to separate the doorphone into two halves. 2. Install the base cover to the...
Page 55
2.4.3Doorphone and Door Opener Connection Connecting Door Openers1. Loosen the screws on the terminal strip. 2. Insert the wires coming from the door opener into the holes and tighten the screws. DOOROPENERTo the door opener /!// Notel We recommend using UL1015 twisted wire or the equivalent for wiring. l The wire should be between 1.2 and 2.4 mm (3/64 - 3/22 inch) in diameter including the coating. +I=D=l.2-2.4 mm (3164-3132 inch) Programming References Section 4, System Programming [607]-[608]...
Page 56
250Auxiliary Connection for Power Failure Transfer Note Feature ReferencesPower Failure Transfer connects a specific standard telephone to a selected outside line in the event of system power failure, as follows:Outside Line 1 - Extension (T, R) Jack 1 Connection of outside line 1 and the respective extension require no auxiliary connection. l In the event of a power failure, system memory is protected by a factory-provided lithium battery. There is no memory loss except the memories of Camp-on, Saved...
Page 57
Closing the Front Cover 1. Fasten all the cables and cords with the cord fastener. 2. Replace the cover and tighten the screw. 3. Tie together all of the connected cords and attach them to the wall so that the cords cannot be pulled out of the system. 2-30Installation
Page 58
Starting the System for the First TimePlug the AC cord into the system AC Inlet and an AC outlet, (The power indicator lights.) Avoid using the same AC outlet for office equipment and this system. Use a dedicated AC outlet only. CAUTION: The power supply cord is used as the main disconnectdevice, ensure that the socket-outlet is located/installed near the equipment and is easily accessible. AC Surge ProtectorInstallation 2-3 1
Page 59
System Restart After starting the system, if the system does not operate properly, restart the system. Before restarting the system, try the system feature again to confirm whether there definitely is a problem or not. System Restart causes the following: 1. Camp-on is cleared. 2. Calls on Hold are terminated. 3. Calls on Exclusive Hold are terminated. 4. Calls in progress are terminated. 5. Call Park is cleared. Other data is not cleared by System Restart. 1. Press the Reset Button with a pointed tool....
Page 60
29a‘,System Data ClearAfter storing or changing the system programming data, it is possible to clear your programming data stored in the system, if required. The system will restart with the default setting. 1. Restart the system using program [900] “System Data Clear”. Programming References Section 4, System Programming [900] System Data ClearInstallation 2-33