Page 41
2.3.3 Extension ConnectionPin Number ChartPin no.Cable Color 26WHT-BLU 1BLU-WHT 27 WI-IT-ORN 2 ORN-WHT 28WHT-GRN 3GRN-WI-IT 29WHT-BRN 4BRN-WHT 30WHT-SLT 5SLT-WHT 31RED-BLU 6BLU-RED 32RED-ORN 7ORN-RED 33RED-GRN 8GRN-RED 34RED-BRN 9BRN-RED 35RED-SLT 10SLT-RED 36BLK-BLU 11BLU-BLK 37BLK-ORN 12ORN-BLK NoteEXTN. l-4 Jack No. 1Jack No.2 Jack No.3 Jack No.4T R DlD2T R Dl D2-T R Dl D2 .-T R Dl D2Pin no.Cable Color 1 EXTN.5-8/Doorphone 39BLK-BRN 14BRN-BLK40 BLK-SLT 15SLT-BLKJack No.5 DlD2 - 42YBL-ORN 17ORN-YEL...
Page 42
2.3.4 Paralleled Telephone Connectionfor a Proprietary Telephone and a Standard TelephoneAny standard telephone can be connected in parallel with a proprietary telephone as follows: Method 1: Using a Modular T-Adaptor L1130Modular T-Adaptor2-conductor wiring cord (Panasonic KX-J66 or USOC RJA2X)BConnect pins ‘7”’ and “R”. 4-conductor wiring cord For a digital proprietary telephone: Connect pins “Dl” and “D2” only. (“T” and “R” are not required.) For an analog proprietary telephone: Connect pins “T”,...
Page 43
2.3.4. Paralleled Telephone Connectionfor a Proprietary Telephone and a Standard Telephone Method 2: For Digital Proprietary Telephones only 2-conductor wiring cord Connect pins ‘7”’ and “R”. Standard TelephoneBack of the telephone Digital Proprietary Telephone4-conductor wiring cordConnect pins “T’, “R”, “Dr” and “D2”. Notel Not only a standard telephone but a single line device such as an answering machine, a facsimile or a modem (personal computer) etc. can be connected in parallel with a proprietary...
Page 44
2.3.5 Extra Device Port (XDP) Connection for a Digital Proprietary Telephone and a Standard TelephoneA digital proprietary telephone (XX-T7220, KX-T7230, XX- T7235, or XX-T7250) and a standard telephone can be connected to the same extension jack yet have different extension numbers (extra Device Port feature). System Programming is required for this jack. Method 1 4-conductor wiring cord Connect pins “Di” and “D2” only. ( “‘I”’ and “R” are for a standard telephone.) I2-conductor wiring cord Digital...
Page 45
2.3.6 Polarity Sensitive Telephone ConnectionCentral Office LineII If your telephone is polarity sensitive+ follow the procedure below: 1. 2. Extension 3. 4. 5. Connect all outside lines. 6. 7. Reverse as shown. 8.Every time an extension telephone is replaced, repeat the above procedure.Complete all the required extension wiring. Confirm that dialing can be done from all the extensions using a touch-tone telephone. If dialing fails, the polarity between the extension and the system must be reversed....
Page 46
2.3.7External Pager (Paging Equipment) ConnectionOne external pager (user-supplied) can be connected to the KX-TD308 as illustrated below. Use an E1A.I RC-6701 A plug (two-conductor, z 2Smm in diameter). l Output impedance: 600 QMaximum length of the cable AWG 18 - 22: Under 10 m (33 feet) Paging Equipment Notel To adjust the sound level of the pager, use the volume control on the amplifier. Programming References Section 4, System Programming [804] External Pager BGM [805] External Pager...
Page 47
2.3.8External Music Source ConnectionOne music source such as a radio (user-supplied) can be connected to the RX-TD308 as illustrated below. Insert the plug to the earphone / headphone jack on the external music source. Use an EIAJ RC-6701 A plug (two-conductor, z 2Smm in diameter). l Input impedance: 8 RMaximum length of the cable AWG 18 - 22: Under 10 m (33 feet) Notel System Programming of music sources used for Music on Hold and Background Music is required. l To adjust the sound level of the...
Page 48
2.3.9Printer and PC Connection A user-supplied printer or personal computer (PC) can be connected to the system. Thse are used to print out or refer to the SMDR call records and system programming data. Connect the printer cable or the PC cable to the Serial Interface (RS-232C) connector. The cable must be shielded and the maximum length is 2 m (6.5 feet). Serial Interface (RS-232C) (g-pin)PrinterorComputer Arrange cables so that the printer will be connected to the system as shown in the chart on the...
Page 49
2.3.9Printer and PC Connection Connection Chart for Printer / IBM Personal Computer with KX-TD308 If you connect a printer or an IBM-PC with a 9-pin cable, follow the chart below. System9-pin Cable Printer/IBM-PC Circuit type c @IA)BB -+-3TXD BA x 4DTR CD 5SGAB 6DSR CC RTSCA CTS CB * RTS (7-pin) and DTR (Cpin) are connected on the board. If you connect a printer or a PC with a 25pin cable, follow the chart below. System25pin Cable Printer/PC Circuit tlVpe WVBB BA CD AB ccCA CB Signalname SGDSR RTS CTS...
Page 50
2.3.9Printer and PC Connection Serial Interface (RS-232C) SignalsFrame Ground: FG Connects to the unit frame and the earth ground conductor of the AC power cord. Transmitted Data: SD (TXD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(output) Conveys signals from the unit to the printer. A “Mark” condition is held unless data or BREAK signals are being transmitted. Received Data: RD (RXD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....