Page 21
11 lSystem Highlights System Capacity Outside line Extension XDP BasicModule SystemExpansion 3- 8- 44 Extra Device Port (XDP) Four extension jacks in the KX-TD308 support the connection of a digital proprietary telephone and a single line device. The two devices per jack have different extension numbers and are treated as two completely different extensions. Paralleled Telephone Connection Every jack in the system also supports the parallel connection of a proprietary telephone and a single line device....
Page 22
11 lSystem Highlights Caller ID Allows the user to see the name or telephone number of a caller on the telephone display before answering a call. Trunk (Outside Line) Answer From Any Station (TAFAS) Ringing occurs over the external paging system; call can be answered from any station. Remote Station Lock Control Allows an operator to lock an extension so that outgoing calls cannot be made. Uniform Call Distribution (UCD) Allows incoming calls to be distributed uniformly to a specific group of...
Page 23
120Basic System Construction The KX-TD308 Digital Super Hybrid System has a basic capacity of three outside lines and eight extensions. It is capable of supporting Panasonic digital and analog proprietary telephone, and single line devices such as standard telephones and fax machines. To expand its capabilities the system can be equipped with optional components or customer-supplied peripherals such as external speaker and external music source (e.g., radio).13 0Proprietary Telephones The following...
Page 24
14lOptions 1.4.14-SLT Extension Expansion Card (KX-TD30870) Adds four extra Device Port extensions to jacks 5 through 8, for a maximum of eight digital extensions plus eight single line device extensions. The basic configuration already supports digital proprietary telephones on jacks 5 through 8. 1.4.2Caller ID / DISA / FAX Detection Card (KX-TD30891) This card supports the following: Caller ID: Receives the Caller ID Service from the Central Office. A specified standard telephone with Caller ID...
Page 25
15lSpecifications 1.51 General Description System CapacityOutside lines Extensions3 max. 8 max. (12 max. with extra Device Port, 16 max. with extra Device Port and 4-SLT Extension Expansion Card) Control MethodCPU: 8 bit CPU Control ROM: 768 KB, Control RAM 128 KB SwitchingNon Blocking PCM Time Sharing Switch Power SuppliesPrimary Secondary120 VAC, 60 Hz (0.7 A) Circuit Volt: +SV, +15V, +3OV DialingDial Pulse (DP) 10 pps, 20 pps, Tone (DTMF) Dialing, DTMF-DP ConnectorOutside lines6-pin Modular...
Page 26
15lSpecifications 1.5.2 Characteristics Station Loop LimitKX-T7220 / KX-T7230 / KX-T7235 / KX-T7250 / KX-T7020 / KX-T7030 / KX-T7050 / KX-T7055 / KX-T7130 . . . . . . ...40 ohms Standard Telephone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600 ohms including set Doorphone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 ohms Minimum Leakage Resistance15,000 ohms Maximum Number of Station Instruments per Line Ring Voltage Central...
Page 27
15aSpecifications 1.5.3 System Capacity Lines, Cards, Station Equipment Item Service Units Outside Lines Extension Jacks Station Terminals 4-SLT Extension Expansion Card Caller ID/DISA/PAX Detection Card Doorphone Door Opener External Pager External Music Source System Data Item Operators System Speed Dialing One-Touch Dialing Station Speed Dialing Call Park areas Absent Messages Toll Restriction Levels Extension Groups Class of Service levels Message Waitings UCD Groups Max. Quantity 1 3 8 16 1 1 1 1...
Page 28
Section 2 Installation This section contains the basic system installation and wiring instructions, as well as how to install the optional cards and units.
Page 29
21aBefore InstallationPlease read the following notes concerning installation and connection before installing the system and terminal equipment. Safety Installation Instructions When installing telephone wiring, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Never install telephone wiring during a lightning storm. 2. Never install telephone jacks in wet locations unless the jack is specifically designed for...
Page 30
210Before Installation 2. If cables are run on the floor, use protectors to prevent the wires from being stepped on. Avoid wiring under carpets. 3. Avoid using the same power supply outlet for computers, telexes, and other office equipment. Otherwise, the system operation may be interrupted by the induction noise from such equipment. 4. Please use one pair telephone wire for extension connection of (telephone) equipment such as standard telephones, data terminals, answering machines, computers, voice...