Page 31
2.2 Installing the Advanced Hybrid System Installation Manual 31 Note To remove the rivet, use a screwdriver as shown below.
Page 32
2.2 Installing the Advanced Hybrid System 32 Installation Manual 2.2.5 Connecting Frame Ground IMPORTANT Connect the frame of the PBX to ground. Be sure to comply with all applicable laws, regulations, and guidelines. Proper grounding is very important to protect the PBX from external noise and to reduce the risk of electrocution in the event of a lightning strike. The AC cables grounding pin may not be enough to protect the PBX from external noise and lightning strikes. A permanent connection...
Page 33
2.2 Installing the Advanced Hybrid System Installation Manual 33 2.2.6 Wall Mounting The PBX is designed for wall mounting only. The wall where the PBX is to be mounted must be able to support the weight of the PBX. When wall mounting the main unit, use either the included screws, or screws of the same size. Mounting on a Wooden Wall The included screws may be used when mounting the main unit on a wooden wall. 1.Place the template (found on the last page of this manual) on the wall to mark the 3 screw...
Page 34
2.2 Installing the Advanced Hybrid System 34 Installation Manual Mounting on a Concrete or Mortar Wall The included screws may be used when mounting the main unit on a concrete or mortar wall. User- supplied anchor plugs are also necessary. 1.Place the template (found on the last page of this manual) on the wall to mark the 3 screw positions. Note When you print out the template, the distance on the paper output may deviate slightly from the indicated measurement. In this case, use the indicated...
Page 35
2.2 Installing the Advanced Hybrid System Installation Manual 35 Notes Do not block the openings of the cabinet. Leave at least 20 cm (8 in) of space above and 10 cm (4 in) to the sides of the PBX for ventilation. Make sure that the wall behind the cabinet is flat and free of obstacles, so that the openings on the back of the cabinet will not be blocked. Be careful not to drop the cabinet.
Page 36
2.2 Installing the Advanced Hybrid System 36 Installation Manual 2.2.7 Installing Surge Protector Overview A massive electrical surge can be caused if lightning strikes a telephone cable 10 m (33 ft) above ground, or if a telephone line comes into contact with a power line. A surge protector is a device that is connected to an outside (CO) line to prevent potentially dangerous electrical surges from entering the building via the outside (CO) lines and damaging the PBX and connected equipment. To...
Page 37
2.2 Installing the Advanced Hybrid System Installation Manual 37 Outside Installation If you install an extension outside of the building, the following precautions are recommended: a.Install the extension wire underground. b.Use a conduit to protect the wire. Note The surge protector for an extension is different from that for an outside (CO) line. Installation of a Ground Rod 1.Connect the ground rod to the surge protector using a grounding wire with a cross-sectional area of at least 16 AWG....
Page 38
2.2 Installing the Advanced Hybrid System 38 Installation Manual 2.Bury the ground rod near the protector. The grounding wire should be as short as possible. 3.The grounding wire should run straight to the ground rod. Do not run the wire around other objects. 4.Bury the ground rod at least 50 cm (20 in) underground. Notes The above figures are recommendations only. The length of the ground rod and the required depth depend on the composition of the soil.
Page 39
2.3 Installing Optional Service Cards Installation Manual 39 2.3 Installing Optional Service Cards 2.3.1 Location of Optional Service Cards Optional service cards are installed by opening the front covers of the main unit and affixing the cards to the appropriate connectors. Each card should be installed in the appropriate location as shown below. See System Components Table for the description of each optional service card. CAUTION To protect the printed circuit boards (P-boards) from static...
Page 40
2.3 Installing Optional Service Cards 40 Installation Manual 2.3.2 3-Port Analog CO Line and 8-Port Hybrid Extension Card (KX-TA82483) Function Adds 3 outside (CO) lines and 8 hybrid extensions on the KX-TA824 basic system. Installing KX-TA82483 to KX-TA824 1.Loosen the screws and open the top and bottom front covers. (→ 2.2.3 Opening/Closing Covers) 2.Using cutting pliers, cut the 6 parts marked with circles, and remove the upper front panel as shown below. 3.Cut off any excess plastic in order to...