Page 11

Installation Manual 11
Table of Contents
1 System Outline ..................................................................................... 13
1.1 System Highlights .......................................................................................................... 14
1.1.1 System Highlights ............................................................................................................. 14
1.2 Basic System Construction...

Page 12

12 Installation Manual
3.1 Installing KX-TA Maintenance Console......................................................................... 74
3.1.1 Installing KX-TA Maintenance Console on a PC ............................................................... 74
3.2 Connection ...................................................................................................................... 76
3.2.1 Connection...

Page 13

Installation Manual 13
Section 1
System Outline
This section provides general information on the PBX, 
including the system capacity and specifications. 

Page 14

1.1 System Highlights
14 Installation Manual
1.1 System Highlights
1.1.1 System Highlights
Built-in Voice Message (BV) (Optional voice message card required) 
Built-in Voice Message (BV) allows a caller to leave a voice message in a users personal message 
area or the PBXs common message area.
Caller ID Display on SLT
The PBX can receive Caller ID information (telephone numbers and callers names) from calls 
received on outside (CO) lines. This information can be shown on the displays of SLTs that...

Page 15

1.1 System Highlights
Installation Manual 15
Refer to the Operating Instructions of the wireless PT for additional information.
Advanced Hybrid System
This PBX supports the connection of PTs, wireless PTs, Direct Station Selection (DSS) Consoles, 
and single line devices such as SLTs, fax machines, wireless SLTs, and data terminals. 

Page 16

1.2 Basic System Construction
16 Installation Manual
1.2 Basic System Construction
1.2.1 Main Unit
The KX-TA824 has a basic capacity of 3 outside (CO) lines and 8 extensions. It is capable of 
suppor ting Panasonic proprietary telephones (PTs), and single line devices such as single line 
telephones (SLTs), fax machines and data terminals.
One Caller ID card is installed by default to support the Caller ID feature for 3 outside (CO) lines.
To expand its capabilities, the PBX can be equipped with optional...

Page 17

1.2 Basic System Construction
Installation Manual 17
1.2.2 System Connection Diagram
 Connect a display-equipped proprietary telephone (PT) to extension jack 01, as this extension is 
automatically designated as the manager extension.
 A PT and a single line telephone (SLT) can be connected in parallel to a Hybrid Por t. (→ 2.5.2 
Connecting Extensions in Parallel)
Door Opener/Doorbell/
Door Chime Doorphone
Paging System
(Loudspeaker, Amplifier 
and Speaker, etc.) Remote PC
PC
PC Printer
Outside (CO)...

Page 18

1.3 Specifications
18 Installation Manual
1.3 Specifications
1.3.1 General Description
Control BusOriginal bus (16-bit, 24 MHz)
SwitchingSpace Division CMOS Crosspoint Switch
Power Input100 V AC to 240 V AC, 1.5 A to 0.75 A, 50 Hz/60 Hz
Maximum Power Failure Tolerance300 ms 
Memory Backup Duration7 years
Dialing Outside (CO) LinePulse (10 pps, 20 pps) or Tone (DTMF)
ExtensionPulse (10 pps, 20 pps) or Tone (DTMF)
Intercom Path4
Mode ConversionPulse-DTMF
Ring Frequency20 Hz/25 Hz (selectable)
Operating...

Page 19

1.3 Specifications
Installation Manual 19
1.3.2 Characteristics
Terminal Equipment Loop LimitPT 40 Ω
SLT 600 Ω including set
Doorphone 20 Ω
Minimum Leakage Resistance15 000 Ω minimum
Maximum Number of Extension 
Instruments per Line1 PT or SLT in standard connection
1 PT and 1 SLT in parallel connection
Ring Voltage75 Vrms at 20 Hz/25 Hz depending on the ringing load
Outside (CO) Line Loop Limit1600 Ω maximum
Hookswitch Flash/Recall Timing 
Range24 ms–2032 ms
Door Opener Current Limit30 V DC/30 V AC, 3 A...

Page 20

1.3 Specifications
20 Installation Manual
1.3.3 System Capacity
System Capacity
Maximum Cards and Terminal Equipment
System Data
KX-TA824
Basic SystemOutside (CO) lines 3
Extensions 8
Fully Expanded SystemOutside (CO) lines 8
Extensions 24
Item KX-TA824
PT 24
SLT 24
3-Port Analog CO Line and 8-Port Hybrid Extension Card 1
2-Port Analog CO Line and 8-Port Hybrid Extension Card 1
8-Port Hybrid Extension Card 1
Message Expansion Card for DISA OGMs 1
4-Port Doorphone Card 1
3-Port Caller ID Card 3
2-Channel...