Page 41

2.3.9 Printer and PC Connection
Installation 2-17 A user-supplied printer or personal computer (PC) can be
connected to the system. These are used to print out or refer to the
SMDR call records and system programming data.
Connect the printer cable or the PC cable to the Serial Interface
(RS-232C) connector. The cable must be shielded and the
maximum length is 2 m {6.5 feet}.
Arrange the cables so that the printer will be connected to the
system as shown in the appropriate chart on the following page....

Page 42

2.3.9 Printer and PC Connection
2-18 Installation
Connection Chart for a Printer / Personal Computer with the KX-TA624
If a printer or a PC with a 9-pin cable is connected, follow the chart
below.
If a printer or a PC with a 25-pin cable is connected, follow the
chart below.
Circuit
type
(EIA)
BB RXDSystem
2
BA
CDTXD
DTR3
4
AB
CCSG
DSR5
6
CA
CBRT S
CTS7
8 Signal
namePin 
no.Circuit
type
(EIA)
BB RXD 9-pin Cable Printer/PC
2
BA
CD TXD
DTR 3
4
AB
CC SG
DSR 5
6
CA
CB RT S
CTS 7
8Signal
name Pin 
no....

Page 43

2.3.9 Printer and PC Connection
Installation 2-19
Serial Interface (RS-232C) Signals
Frame Ground: FG
Connects the unit frame and the earth ground conductor of the AC
power cord.
Transmitted Data: SD (TXD) RRRRRRRR(output)
Conveys signals from the unit to the printer. A “Mark” condition is
held unless data or BREAK signals are being transmitted.
Received Data: RD (RXD) RRRRRRRRR(input)
Conveys signals from the printer.
Request to Send: RS (RTS) RRRRRRRRR(output)
This lead remains ON whenever DR (DSR) is...

Page 44

2.4 Installation of Optional Cards
2-20 Installation
2.4.1 Location of Optional Cards
The location of the optional cards is shown below.
PrecautionTo protect the printed circuit boards (P-boards) from static electricity, do
not touch parts on the P-boards in the main unit and on the optional
cards. If accessing the part is required, wear a grounding strap.
The front covers are open.
Caller ID Card (KX-TA62493)
ConnectorOGM/FAX Detection Card (KX-TA62491) 
Connector3 CO Line and 8 EXT 
Expansion Card...

Page 45

2.4.2 Caller ID and OGM/FAX Detection Card Installation
Installation 2-21 A Caller ID Card (KX-TA62493) and OGM/FAX Detection Card
(KX-TA62491) can be installed to the system.
The Caller ID Cardsupports the following.
Caller ID: Receives the Caller ID Service from the Central Office.
A display proprietary telephone with Caller ID service can
display the information. It can also display caller’s information
which has been stored in the system according to the Caller ID
service.
The OGM/FAX Detection...

Page 46

2.4.2 Caller ID and OGM/FAX Detection Card Installation
2-22 Installation
Caller ID Card
(KX-TA62493)
Install the Caller ID Card for
the KX-TA62477 here.
Note
Please do not damage this part.
OGM/FAX Detection Card
(KX-TA62491)
3.Attach the optional cards.
4.Insert the flat cables to each card connector.
5.Close the cover.
Condition• Be sure the frame of the main unit is connected to the ground. Refer to
Section 2.2.4 “Frame Ground Connection”.
Programming Reference
See “Programming References” in Section...

Page 47

2.4.3 Doorphone and Door Opener Connection
Installation 2-23 Four doorphones (KX-T30865) and four door openers (user-
supplied) can be installed.
Maximum cable length
The maximum length of the doorphone and door opener line cord
which connects the system is as follows.
Diameter of the line Max. length
Doorphone22 AWG 180 m {590 feet}
(Station Loop  24 AWG 113 m {370 feet}
Limit: 20 ½) 26 AWG 70 m {230 feet}
Door Opener22 AWG 180 m {590 feet}
Installing the Doorphone
1.Loosen the screw to open the...

Page 48

2.4.3 Doorphone and Door Opener Connection
2-24 Installation
Doorphone/Door Opener Installation
Attach the Doorphone/Door Opener Card to the main unit, connect
the cord to the doorphone/door opener card connector and secure
the screw.
Doorphone Connectors
Door Opener Terminal 
Doorphone/Door Opener Card
 (KX-TA62460)Screw
Doorphone/Door Opener Card
 Card Connector 

Page 49

2.4.3 Doorphone and Door Opener Connection
Installation 2-25
Wiring of the Doorphone
1.Connect the Doorphone/Door Opener Card to the terminal
boxes using 4-conductor modular connectors.
2.Connect the wires of doorphones 1 and 3 to the red and green
screws on the terminal box.
3.Connect the wires of doorphones 2 and 4 to the yellow and
black screws on the terminal box.
PanasonicPanasonic
PanasonicPanasonic
Yellow
RedBlack
Green 4-conductor wiring
is required.
4-conductor wiring
is required. Doorphone 1...

Page 50

2.4.3 Doorphone and Door Opener Connection
2-26 Installation
Connecting Door Openers
While pressing the button below a hole with a driver, insert the wire
from the door opener into the hole.
Note• We recommend using UL1015 wire or the equivalent for wiring.
• The wire should be between 0.4 mm and 1.2 mm {1/64 inch –   3/64 inch}
in diameter including the coating.
Door opener 1
Door opener 2
Door opener 3Door opener 4
To the door openers
D = 0.4 mm – 1.2 mm {1/64 inch – 3/64 inch} 