Page 31
2.3 Connection Installation 2-7 6 Outside (CO) Lines 24 Extensions Doorphones KX-T30865 Door OpenersExternal Music Source Amplifier Speaker Printer or Computer (two pair) (two pair) (two pair) (two pair) (two pair)(two pair) (one pair) (one pair) (one pair) (one pair) (one pair) Single Line Telephone Data Terminal Cordless Phone Telephone Answering Machine with Facsimile Voice Processing SystemKX-T7055 KX-T7050 KX-T7020 KX-T7030 KX-T7130 KX-T7040 Panasonic Panasonic Panasonic Panasonic to outside (CO)...
Page 32
2.3.2 Opening the Front Cover 2-8 Installation1.Loosen the screw. 2.Remove the top front cover. NoteThe screw cannot be removed from the cover. Top front cover Screw
Page 33
2.3.3 Outside (CO) Line Connection Installation 2-9 Connection 1.Insert the modular plugs of the telephone line cords (2-conductor wiring) into the modular jacks on the system. 2.Connect the line cord to the terminal board or the modular jacks from the Central Office jack. POWER To Terminal Board or Modular Jacks from the Central OfficeTRT: Tip R: Ring View of TEL Jack (Outside (CO) Line)
Page 34
2.3.3 Outside (CO) Line Connection 2-10 Installation Installing Lightning Protectors A lightning protector is a device to be installed on an outside (CO) line to prevent a dangerous surge from entering the building and damaging the equipment. A dangerous surge can occur if a telephone line comes in contact with a power line. Problems due to lightning surges have been steadily increasing with the development of electronic equipment. In many countries, there are regulations requiring the installation of a...
Page 35
2.3.3 Outside (CO) Line Connection Installation 2-11 Installation of an Earth Rod 1) Installation location of the earth rod RRNear the protector 2) Check obstructions RRRRRRRRRNone 3) Composition of the earth rod RRRRRMetal 4) Depth of the earth rod RRRRRRRMore than 50 cm {20 inches} 5) Size of the grounding wire RRRRRRThickness more than 16 AWG Note• The above example is only a recommendation. • The length of the earth rod and required depth depend on the composition of the soil. Lightning Protectors...
Page 36
POWER To extensions (JACK 01–08)THRL H: High T: Tip R: Ring L: Low View of TEL Jack (Extension) 2.3.4 Extension Connection 2-12 InstallationExtension jacks 01 – 08 are for all kinds of telephones. Telephone Wiring The maximum length of the extension line cord (twisted cable) which connects the system and the extension is as follows. Diameter of the line Max. length Single Line Telephone22 AWG 1798 m {5900 feet} (Station Loop Limit: 24 AWG 1128 m {3700 feet} 600 ½including set) 26 AWG 698 m {2290 feet}...
Page 37
2.3.5 External Pager (Paging Equipment) Connection Installation 2-13 Note• To adjust the sound level of the pager, use the volume control on the amplifier. Programming Reference Section 4, System Programming [106] External Paging Access Tone Feature ReferencesSection 3, Features Paging – All Paging – External One external pager (user-supplied) can be connected to the KX-TA624 as illustrated below. Use an EIAJ RC-6701 A plug (two-conductor, ø 3.5 mm in diameter). • Output impedance: 600 W Maximum length of...
Page 38
2.3.6 External Music Source Connection 2-14 InstallationOne music source, such as a radio (user-supplied), can be connected to the KX-TA624 as illustrated below. Insert the plug to the earphone/headphone jack on the external music source. Use an EIAJ RC-6701 A plug (two-conductor, ø 3.5 mm in diameter). • Input impedance: 8 W Maximum length of the cable AWG 18 – 22: Under 10 m {33 feet} POWER EXT. MUSIC External Music source External Music Jack Note• System programming for the music source used for Music...
Page 39
2.3.7 Paralleled Telephone Connection (for a Proprietary Telephone and a Single Line Telephone) Installation 2-15 Any single line telephone can be connected in parallel with a proprietary telephone as follows. Using a Modular T-Adaptor Modular T-Adaptor (Panasonic KX-J66 or USOC RJA2X) 2-conductor wiring cord Connect pins “T” and “R”. Proprietary Telephone Single Line Telephone 4-conductor wiring cord For a proprietary telephone: Connect pins “T”, “R”, “H” and “L”. Programming Reference Section 4,...
Page 40
2.3.8 Polarity Sensitive Telephone Connection 2-16 InstallationIf the telephone is polarity sensitive, follow the procedure below: 12 34 5678 90 Outside (CO) Line Reverse hereExtension 12 34 5678 90 Outside (CO) Line Reverse hereExtension 1.Complete all the required extension wiring. 2.Confirm that dialing can be done from all the extensions using a touch-tone telephone. If dialing fails, the polarity between the extension and the system must be reversed. 3.Reverse as shown. 4.Unplug the system. 5.Connect...