Home > Panasonic > Communications System > Panasonic Kx-a271 Eia/Remote Programming And Diagnosis Manual

Panasonic Kx-a271 Eia/Remote Programming And Diagnosis Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Kx-a271 Eia/Remote Programming And Diagnosis Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							2-8 Operating Flow Chart 
    i ,: 
    [ I Batch Editing Mode 
    ._ 
    ., 2. 
    I_ 
    : 
    Set FD or ND 
    Save the system data Load the system data 
    (See “Chapter 7 DSHS 
    c]::tyl;::;:::) Edltmg the data In (See Chapter 4 System 
    I I 
    I 
    0 
    Saving the file 
    -~ 
    I I 
    , 1 
    Connecting with Connect PC with DSHS 
    (See “Chapter 7 DSHS 
    * Setting the file Set FD otHD 
    DSHS 
    Connect / Disconnect) 
    1 I -~ 1 I 
    I I 
    Loading the data of * Load the system data . Save the system data 
    PC DB into DSHS of PC DB into DSHS DB Saving the data of of PC DB into FD or 
    (See “Chapter 6 DSHS PC DB into the file HD (See “Chapter 5 
    DB 
    J Management”) - Disk FiIe Manage- 
    I 
    ‘I Disconnect PC from DSHS ment”) 
    Disconnecting from (See “Chapter 7 DSHS 
    DSHS 
    Connect I Disconnect”) 
    I 
    . 
    2-12  
    						
    							2 Interactive Editing Mock 
    I I 
    / Interaz%iiting 1 
    1 
    I 1 . 
    I 
    Starting the system 
    (The initial screen 
    I 
    Edit the data of DSHS DB 
    “Chapter 4 System 
    Disconnect PC from DSHS 
    (SW Chapter YDSHS 
    2-13  
    						
    							2-9 enu Tree 
    mote> Main Menu 
    m Menu 
    {Line} Edit 
    -/ Station 
    ----r--v-. 
    . 1 DSS 
    I 
    rSy Day/Night  stem 
    ------- 
    Class of Service 
    ---*A------ 
    Soeed Dial 
    ------- 
    1 ARS 
    I ARS Mode/Time/Modify Data 
    -mm---- 
    ARS Routin@an 
    ---- ----- 
    ARS Leading Digit 
    [ Aux. Ports 
    I Music & PagQ 
    v--e ----- 
    Administration & SMDR & *MODEM 
    -------_____ 
    *DISA 
    -f Disk File Management 1 
    4DSHS Management1 {Addnional Function 
    {Caller ID 
    System Data Save 
    f System Data Load 
    *Test 
    f *DTMF G/R Test 
    ---w-w--- 
    *EXT Card Test 
    ------____ 
    *DISA Card Test 
    e-e--_____ 
    { RS232C Connect 
    *MODEM Connect 
    *: Available for KX-TD1232 only. I 
    [ Dtsconnect 
    1 
    2-14  
    						
    							Intial Screen 
    The screen below is displayed when you start the DSHS program. 
    Main Menu Off-line KX-TD1232 Both 
    Panasonic 
    Digital Super Nybrid System 
    Operating & Maintenance Tool Ver 2.xX 
    (C) COPYRIGHT 1993 KYUSHU MATSUSHITA ELECTRIC CO., LTD. 
    1. System Data Programming (Batch) 
    2. System Data Programming (Interactive) 
    3. Disk Pile Management 
    4. DSHS Management 
    5. DSHS Connect / Disconnect 
    6. Quit 
    Select the number :[J 
    Enter the number, and hit ENTER key 
    @j 
    @j 
    m HELP &j @j fj 
    p.j 
    . 
    -  
    [l] System Data Programming (Batch) 
    Edits System Data in Batch Editing Mode. 
    [2] System Data Programming (Interactive) 
    Edits System Data in Interactive Editing Mode. 
    [3] Disk Pile Management 
    Loads the data from the disk and saves them into the disk in Batch Editing Mode. 
    [4] DSHS Management 
    Saves the data from DSHS and loads them into DSHS in Batch Editing Mode and also diagnoses 
    DSHS in Interactive Editing Mode. 
    3-1  
    						
    							[S ] DSHS Connect / Disconnect 
    Connects the PC terminal with the DSHS by RS-232C or MODEM and disconnects from the DSHS. 
    [6] Quit 
    Returns to MS-DOS System. 
     
    (1) Enter the number of the program, and press ENTER key. 
    (2) When you select “1. System Data Programming (Batch)“, you must choose “3. Disk File Manage- 
    ment” or “4. DSHS Management” first to load or save the system data into PC DB . 
    (3) When you select “2. System Data Programming (Interactive)” or “4. DSHS Management”, you must 
    choose “5. DSHS Connect / Disconnect” first to connect the PC terminal with the DSHS. 
    (4) Select “6. Quit” to return :o 
     
    When you select “2. System Data Programming (Interactive)” or “4. DSHS Management” without 
    connecting the PC terminal with the DSHS, a message “Please connect with the DSHS by 
    5. DSHS Connect / Disconnect”. 
    3-2  
    						
    							ain enu 
    The screen below appears first when you select “1. System Data Programming (Batch)“. 
    System Data Programming Main Menu Off-line 
    . KX-TD1232 Both 
    1. Line 
    2. Station 
    3. System 
    4. Toll Restriction 
    5. ARS 
    6. Aux. Ports ’ 
    7. Additional Function 
    8. Caller ID 
    Select the number : [J 
    Enter the number, and hit ENTER key 
     
    (1) 
    Enter the number of the program, and press ENTER key. 
    (2) Press F8 (EXIT) to return to the initial screen. 
    4-1  
    						
    							4-2 Line 
    The screen illustrated below appears when you select “1. Line”. 
    Line Menu 
    Off-line KX-TD1232 Both 
    1. CO Line Setting 
    2. CO Line Groups (TRG) 
    Select the number : [-I 
    Enter the number, and hit ENTER key 
    fjYj @ 
    gj fi HELP m 
    @ B 
    II3 EXIT 
     . 
    (1) 
    Enter the number of the program, and press ENTER key. 
    (2) Press F8 (EXIT) to return to Main Menu screen. 
    4-2  
    						
    							1. CO Line Setting 
    i 
    CO Line Setting 
    Off-line KX-TD816 
    COC T D D P C 
    CPC DIL 1 : 1 Reverse 
    No. 0 R I T P I Detection EXT No. Circuit 
    N G A M S D Mode out 
    Day Night 
    L F 
    01 [ll D 80 10 N 
    02 N [2] P 160 20 N 
    03 Y’ [3] D 80 10 N 
    04 Y [4] P 80 10 N 
    05 Y [5] P 80 10 N 
    c., -7 r,3 - n-. -r -. 
    ;;7” ; ~~; ~ ;;;; ;;; ~ 
    08 Y [SJ P 80 10 N Disable Disable 
    1OOms Enable 
    2OOms Enable 
    3OOms Enable 
    4OOms Enable 
    -em 
    3UUlIl~ EIIcliJiL 
    6OOms Enable 
    400ms Enable EXlJ109] EX’ljW] Reverse 
    Disable Disable Regular 
    Disable Disable Regular 
    Disable Disable Regular 
    Disable Disable Regular 
    iXh&ii iL&ic ikguidr 
    Disable Disable Regular 
    Disable Disable Regular 
    IIit spacebar to select parameter 
     
    [l] CON (CO Line Connection Assignment) 
    ]4001 
    Assigns connecting states of CO lines. 
    [2] TRG (CO Line Group Assignment) 
    I4011 
    Assigns individual CO lines to one CO line group. 
    [3] DIAL (Dial Mode Selection) 
    [4w 
    Assigns the dial mode to each CO line. 
    [4] DTMF (DTMF Time) 
    [4041 
    Sets the DTMF time of CO lines. It is available when the dial mode is assigned DTMF. 
    [S] PULSE PPS (Pulse Speed Selection) 
    14031 
    Sets the pulse speed of CO lines. It is available when the dial mode is assigned PULSE. 
    [6] CID (Caller ID Assignment) [406] 
    Assigns to identify calling panics. 
    4-3  
    						
    							[7] CPC Detection Mode (CPC Signal Dctcction Incoming Set) [4051 
    Sets the CPC signal dctcction time when cithcr calling or called party goes on hook. 
    [S] CPC Detection Out (CPC Signal Dctcction Outgoing Set) 
    r4151 
    Assigns to enable or disable to dclcct the CPC signal while calling . 
    [9] DIL 1 : 1 EXT No. Day /Night 
    (Direct In Line Extension -Day /Night) [407,408 ] 
    Assigns an extension for a DIL 1: 1 destination during day time or night time. 
    [lo] Reverse Circuit (Reverse Circuit Assignment) 
    Enables or disables to detect Reverse Circuit. 
    a This feature is available for KX-TD816 only. . 
    14161 
     
    (1) For KX-TD1232, this program consists of two pages. One displays CO No.01 through 12aand the 
    other displays CO No. 13 through 24. 
    For KX-TD816, this program consists of one page. It displays CO No.01 through 08. 
    (2) Move the cursor to the field in which you want to set a parameter. 
    (3) After editing the data, press F7 (SAVE) to save them on the screen into DB file. 
    (4) Use F2 (COPY) if you want to copy the data of one CO No. in another. 
    (5) Press F8 (EXIT) to return to Line Menu screen. 
     
    (1) It is possible to assign Floating Extension Number as an extension number in DIL 1 : 1. 
    (2) When the single system is operating, the data of DIL 1 : 1 of the system which is not operating 
    cannot be assigned and they are not displayed in the screen. 
    (3) When you copy the data of DIL 1: 1, it is invalid to copy in or from the data which are not displayed. 
     , 
    The numbers beside the items arc program addresses which are used when you program the system by 
    proprietary telephones. 
    4-4  
    						
    							TABLE of ITEMS 
    Assigning 
    Items Type of Field Sclcction of paramctcr Default 
    CON Selecting 
    Y : 
    COMCCL or N : Disconnect Y 
    coOl=l, cm2=2 
    co03=3. coo4=4 
    TRG Direct 1 through 8 1 digit coos=s, coobd 
    . 
    COOM. COO8=8 
    ----- 
    COO9=8through 
    CO24=8 (KX-TD1232 
    D : DTMF, P : Pulse. C : Call Block 
    Y : Identify or N: Not identify ’ 
    CPC 
    Detection 
    diode Selecting Disable, lOOms, 2OOms. 3OOms, 4OOms. 5OOms, 6OOms 400ms 
    CPC 
    Detection 
    3ut Selecting Disable or Enable Disable 
    DlLl : 1 
    Xl- No. 
    Day /Night 
    Xeverse 
    Zircuit Selecting 
    and 
    Direct 
    Selecting Disable or EXT [ ] 
    (After selecting EXT [ 1) 
    0 through 9 . 
    2.3 or 4 digits 
    Reverse (detection) or Regular (no detection) Disable 
    Regular 
    4-5  
    						