81 •Your iris data may not be enrolled in the iris reader. •You may not have passed your card cor- rectly through the card reader (if a card reader is used). •Power may not be supplied to the iris reader. •The indicator is set not to light up by the administration software. •A smudge may be on the front panel or the panel may be damaged. If a lens has slipped off the eyes corneal surface, the contact edge may hide the iris images. That may cause invalid recognition. In this case, move the contact lens back to the corneal surface by blinking. The contact lenses may have not been on the appropriate position. You may have been wearing color contact lenses.Depending on the lens type, recognition may be invalid. Cases of Enrollment/Recognition Failure •You have closed your eyes or not opened your eyes widely during capturing. •You were wearing sunglasses whose lens color is too deep to be captured •Smudges were sticking on the glasses. •You were not looking at the mirror during capturing. •Your position is too near or too far from the iris reader to be captured. When you come within approx. 50 cm {1.64 ft.} of the iris reader, the guidance will start. The recognition range between the eyes and mirror is approx. 30 cm to 40 cm {0.98 ft. to 1.32 ft.}. Before Requesting for Repair Check to see the following before requesting for repair. Do not attempt anything other than the described actions herein. If the trouble cannot be corrected even after checking and trying remedy, contact your dealer. The live indicator does not light up.Refer to system administrators. Enrollment/Recognition is invalid. Refer to system administrators. Refer to p. 11. (If the front panel needs replacement, refer to service personnel.) Check itemRemedy ProblemCheck item Remedy
82 All the five lamps of guide indicator is lighting, but the iris reader does not work. External strage device is not detected. Buzzer sound is heard and all of the distance indicator and result indicator are blink- ing. All the five lamps of guide indicator and result indicator light up. Voice guidance is not heard. Enrollment/Recognition is invalid. •You may not have opened your eyes widely during capturing. •You may have been looking above or below the mirror. •You may have moved quickly during cap- turing. •Light has been reflecting on the glasses. •The contact lenses may have not been in the appropriate position. •You may have been wearing color con- tact lenses. In the following cases, the recognition/ enroll- ment will fail. •You have closed your eyes or not opened your eyes widely enough during captur- ing. •You were wearing sunglasses whose lens color is too deep to be captured. •Smudges were on the glasses. •You were not looking at the mirror during capturing. •Your position is too near or too far from the iris reader to be captured. Refer to pages 68 and 80. •The audio level of voice guidance may be set to the minimum. •The voice guidance may be set to Mute by the administration software.Refer to system administrators. •The iris data may be being distributed to the iris reader, or the iris reader may be being reset. The operation of the iris reader will be available after waiting for a while. (In the maximum case, it takes approx. 5 minutes.) •If the iris reader still cannot be operable, the operation of the iris reader will be stopped by the settings of the administra- tion software.Refer to system administrators. The tamper detection mode is activated. Refer to system administrators. The iris reader may be set to the enrollment mode. Is the device formatted by the FAT32 form?Refer to system administrators. – ProblemCheck item Remedy
83 General Power source *1: 12 V DC/24 V DC Power consumption: 14.4 W Ambient operating temperature: 0 °C to +40 °C {32 °F to 104 °F} Ambient operating humidity: 30 % to 90 % Dimensions: 203 mm (W) x 190 mm (H) x 65 mm (Moving part: 77 mm) (D) {8 in. (W) x 7.48 in. (H) x 2.56 in. (Moving part: 3.03 in.) (D)} Weight: 0.9 kg{1.98 lbs.} Interface: Wiegand, RS-485 * 6 Network: 10 Base-T/100 Base-TX (Auto negotiation) *2 Network protocol: TCP/IP Available card reader: RWK400 (Manufactured by HID Corporation) *7 Recommended junction box: Two-gang junction box Input/Output Recognition result output1 (ACCEPT): Non-voltage make contact output, Normally Open, Pulse width: 0.1 s to 60 s, 24 V DC, 100 mA (Max), ON resistance 6 Ω Trigger input (recognition start): 0 V to 5 V, 24 mA (Max), Active low, Pulse width: 200 ms or more Audio output (Pre-out):φ3.5 mm stereo mini plug (10 kΩ, –16 dBV) Note:Connect the audio output cables to the stereo speakers equipped with the audio amplifier. (When connected to a monaural speaker, no sound may be heard.) High speed serial interface: Numeric key, external storage device* 5 Interface board Interface (card reader): Wiegand, RS-485 (Either can be selected.) Wiegand power output (card reader): 5 V DC, 100 mA (Max) Wiegand DATA0 input (card reader): 0 V to 5 V DC, 25 mA (Max), Active low Wiegand DATA1 input (card reader): 0 V to 5 V DC, 25 mA (Max), Active low RS-485 (A), (B) (card reader): Differential input: ± 0.2 V or more, Differential output: ±2 V or more (When termina- tion is ON)* 6 Interface (access control panel): Wiegand, RS-485 (Either can be selected.) Wiegand power input (access control panel): 5 V DC (No connection available) Wiegand DATA0 output (access control panel): 0 V to 5 V DC, 25 mA (Max), Active low Wiegand DATA1 output (access control panel): 0 V to 5 V DC, 25 mA (Max), Active low Wiegand ACCEPT-LED input (access control panel): 0 V to 5 V, 24 mA (Max), Active low, Pulse width: 200 ms or more Wiegand REJECT-LED input (access control panel): 0 V to 5 V, 24 mA (Max), Active low, Pulse width: 200 ms or more RS-485 (A), (B) (access control panel): Differential* 6input: ± 0.2 V or more, Differential output: ±2 V or more (When termina- tion is ON) *6 Alarm output1 (tamper detection): Open collector output, Normally Open, Active low, 24 V DC, 24 mA (Max) Alarm output2 (power status): Open collector output, Normally Close (Low level), 24 V DC, 24 mA (Max) Recognition result output2 (REJECT): Open collector output, Normally Open, Active low, Pulse width: 0.1 s to 60 s, 24 V DC, 24 mA (Max) Buzzer input: 0 V to 5 V, 24 mA (Max), Active low, Pulse width: 200 ms or more Time adjust input: 0 V to 5 V, 24 mA (Max), Active low, Pulse width: 100 ms or more* 5 Option camera (Not supplied to the iris reader) Video output: 1.0 V [P-P]/75 Ω, composite (NTSC) Specifications
84 Function Iris recognition time: Approx. 0.3 seconds (After iris image capturing until the recognition result is output) * 2 Approx. 5 seconds (Server certification. After iris image capturing until the recogni- tion result is output) *3 Eye image capturing range: Approx. 30 cm to 40 cm {0.98 ft. to 1.32 ft.} between the eyes and the mirror Total number of users enrolled Stand-alone mode: 50 users max. Network mode: 5 025 users max.* 4 Iris server: 10 025 users max.*4 Voice guidance: 14 languages supported (Japanese, English, German, French, Spanish, Italian, Russian, Chinese, Korean, Portuguese, Turkish, Arabic, Dutch, and Swedish) Mute, Simple (Recognition result), and Full (Voice guidance, and recognition result) selectable Distance indicator: Five lamps Live indicator: Blinking, On, and Off selectable Angular field view (video surveillance camera): Horizontal: 115 °, Vertical: 85°(Fixed) (In some cases, horizontal angular field of view of option camera is partly missing.) Security function: Tamper detection switch, iris data encryption Time adjustment: Synchronization with an external master clock * 1The third-party external power supply should meet the following specifications, and must be powered by a UL Listed access control power-limited power supply, capable of 4-hours of standby power. Rated ripple voltage/Ripple noise: 150 mV[P-P] or less Overcurrent protection: Enabled (mandatory) * 2This iris reader supports auto negotiation. If you use a hub supporting auto sensing, connection may not be established due to auto sensing malfunction. * 3The recognition time may differ depending on capturing conditions, network conditions, or the total number of enrolled users. * 4User Licence Software BM-EU30000E Series (option) is required. *5Refer to the dealer for available external devices. *6For RS-485 communication, our exclusive protocol is employed. *7For use with RS485 only. Refer to UL Listed Access Control Panels Installation Instructions for compatibility with this UL Listed reader. Operating Instructions (This document) .......................... 1 pc. The following parts are used during installation procedures. Earth ground cable .......................................................... 1 pc. Clamping tool ................................................................... 1 pc. Clamping tool screw (3 mm tapping screw) .................... 1 pc. Tamperproof screw driver tool ......................................... 1 pc. Ferrite core ....................................................................... 2 pcs. Warranty card ................................................................... 1 pc. Standard Accessories 12 V DC 12 V DC ±0.5 V Minimum 1.2 A 24 V DC 24 V DC ±0.5 V Minimum 0.6 AOutput voltage Output current capacity
Panasonic Canada Inc.5770 Ambler Drive,Mississauga, Ontario, L4W 2T3 Canada (905)624-5010 http://www.panasonic.ca Panasonic Sales Company Division of Panasonic Puerto Rico Inc. San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina P.R. 00985(809)750-4300 Panasonic System Solutions Company, Unit Company of Panasonic Corporation of North America Security Systems www.panasonic.com/security For customer support, call 1.877.733.3689 Executive Office: Three Panasonic Way 2H-2, Secaucus, New Jersey 07094 Zone Office Eastern: Three Panasonic Way, Secaucus, New Jersey 07094 Central: 1707 N. Randal Road, Elgin, IL 60123 Southern: 1225 Northbrook Parkway, Suwanee, GA 30024 Western: 6550 Katella Ave., Cypress, CA 90630 © 2006 Matsushita Electric Industrial Co., Ltd. All Rights Reserved. NM1006-2047 V8QA6480CN Printed in Japan