Home
>
Panasonic
>
Camera Accessories
>
Panasonic Indoor Pan Tilt Head Aw Rp400 Operating Instructions
Panasonic Indoor Pan Tilt Head Aw Rp400 Operating Instructions
Here you can view all the pages of manual Panasonic Indoor Pan Tilt Head Aw Rp400 Operating Instructions. The Panasonic manuals for Camera Accessories are available online for free. You can easily download all the documents as PDF.
Page 31
Pan/Tilt Control Panel AW-RP400 AW-RP400 31 Menu settings OPTION SWITCH A to H settings (NOT USE / DEF / WIP / HEATER/FAN / LAMP / OPTION / ND / EXT / AF) The following functions can be allocated to OPTION buttons A to H. Different functions can be allocated for different pan/tilt heads. NOT USE:The button is disabled. DEF:This controls the ON and OFF states of the defroster function when using a pan/tilt head system equipped with this function. Each time the button is pressed, ON is switched to OFF or...
Page 32
Pan/Tilt Control Panel AW-RP400 32 Menu settings CONTROL SELECT MODE setting (INTERLOCK/UN-INTERLOCK) This menu item is for selecting the method used to select the pan/tilt head and camera when the AW-CB400 remote operation panel has been connected to the AW-RP400 control panel. INTERLOCK:When the pan/tilt head and camera system are selected by the AW-RP400 or AW-CB400, the same system is selected by the other unit as well. UN-INTERLOCK:A different pan/tilt head and camera system can be selected by the...
Page 33
Pan/Tilt Control Panel AW-RP400 AW-RP400 33 How to mount the AW-RP400 in a rack AW-RP400 320mm 1Use the accessory mounting screws (M4!8 mm) to attach the rack-mounting adaptors. Rack-mounting adaptor Accessory mounting screws (M4!8 mm) 4 pcs ≥The AW-RP400 is 320 mm wide. If it is to be installed in a full-size rack (which accommodates units totaling 420 mm in width), provide panels or other parts to supplement the AW-RP400’s width so that it will fill the rack width-wise. ≥If the AW-RP400 is joined to...
Page 34
Pan/Tilt Control Panel AW-RP400 34 How to change the position of the connector panel The position of the connector panel can be changed from the rear panel to the bottom panel. 1Remove the five bottom panel screws, and remove the blank panel. 2Remove the five rear panel screws, and remove the connector panel. 5Secure the connector panel to the bottom panel using the screws. 3Secure the blank panel to the rear panel using the screws. 4Remove the two rubber feet from the blank panel. Screws!5 (bottom...
Page 35
Pan/Tilt Control Panel AW-RP400 AW-RP400 35 How to replace the zoom switch 1Remove the four screws that secure the zoom lever. 2Pull out the zoom lever, disconnect the two cables from the circuit board inside, and remove the zoom lever. 3Plug the two cables extending from the zoom switch into the connectors on the circuit board inside. 4Secure the zoom switch using the four screws. Screws!4 Screws!4 ❈Before replacing the zoom switch, turn off the power.
Page 36
Pan/Tilt Control Panel AW-RP400 36 Replacing the consumable parts The joysticks and zoom switch are consumables. Replace them if they are not working properly. Ask your dealer to do the replacement work.
Page 37
Pan/Tilt Control Panel AW-RP400 AW-RP400 37 Specifications Input connectors DC 12V IN: XLR, 4 pins CONTROL IN FROM ROP: D-SUB 29-pin, cable supplied with AW-CB400 remote operation panel CONTROL IN FROM RCB: 10-pin round connector, cable supplied with WV-CB700A EXT CONT IN: RJ45, additional AW-RP400 control signal input; 10BASE-T straight cable (UTP category 5), max. 500 meters REMOTE: 50-pin D-SUB connector, external control input, AW-CA50T9 Output connectors CONTROL OUT TO PAN/TILT HEAD: RJ45,...
Page 38
Cable Compensation Unit AW-RC400 38 Introduction Accessories ≥The AW-RC400 is capable of providing cable compensation for analog composite, analog Y/C or analog component signals in five channels up to 500 meters (when the BELDEN 8281 connecting cable or its equivalent is used). ≥It features a 5µs advance function for the sync signals in order to provide easy support for a system (another cable compensation unit is required) in which the coaxial cable connected between this AW-RC400 cable compensation...
Page 39
Cable Compensation Unit AW-RC400 AW-RC400 39 Parts and their function 1Power LED This lights up green when the (2) POWER switch is set to ON while a DC 12V voltage is supplied to the (7) DC 12V IN socket. 2POWER switch Set this to ON to turn on the cable compensation unit’s power. Part of the power supply circuitry will still operate even when the power switch is at the OFF position. To turn off the power completely, disconnect the AC adaptor. 3Cable length setting switches [0 to 5] Set these switches...
Page 40
Cable Compensation Unit AW-RC400 40 Parts and their function ;MONITOR1, 2 connectors The video signals of the cameras selected by the AW-RP400 pan/tilt control panel or the AW-CB400 remote operation panel which is connected to the AW-RP400 are output from these connectors. The output signals are cable-compensated signals of the same type as the input signals. For instance, if a channel to which composite signals have been input is selected, these composite signals will be cable-compensated and...