Have a look at the manual Panasonic DLP Based Projector PT-D7700U PT-DW7000U Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
91 Press the “ENTER” button. The OPTION screen will be displayed. Select “NETWORK SETTING” with the buttons. Initial setting of network module Procedure of setting • It takes about two minutes for the setting to be reflected in the system. • Do not turn off the main power supply until the on- line lamp of network module turns on again. Press the “MENU” button. The MAIN MENU screen will be displayed. Select “OPTION” with the buttons. MAIN MENU PICTURE POSITION ADVANCED MENU LANGUAGE OPTION TEST PATTERN SIGNAL LIST SECURITY :MENU SELECT ENTER:SUB MENU OPTION PROJECTOR ID 2 SETTING FRONT-F LAMP SELECT DUAL LAMP POWER HIGH RS232C SETTING OSD POSITION 2 SYSTEM INFORMATION COLOR MATCHING 3COLORS VIDEO SETTING NETWORK SETTING :MENU SELECT ENTER:SUB MENU NETWORK SETTING HOST NAME PROJECTOR DHCP OFF IP ADDRESS 192.168. 0. 8 PORT 80 NET MASK 255.255.255. 0 GATEWAY 192.168. 0. 1 MAC ADDRESS 00.00.00.00.00.00 STORE :MENU SELECT ENTER:ADJUSTPress the “ENTER” button. The NETWORK SETTING screen will be displayed. Select items with the buttons and press the “ENTER” button to change the setting. Select the “STORE” with the buttons and press the “ENTER” button twice. The on-line lamp of network module turns off and then turns on. Note (Continued on next page)
92 How to use network module (optional) • Avoid activating two or more Web browser simultaneously to work out setting or control actions. • This feature is effective when the on-line lamp of network module is lighting. • Change the password first of all. Items FunctionDescription HOSTNAME DHCP IP ADDR PORT No. NET MASK GATEWAY MAC ADDRMake alteration if necessary when to use the DHCP server. Set the DHCP item to ON when to acquire an IP address automatically using the DHCP server. Set to OFF if DHCP server is not used. Enter the IP address if DHCP server is not used. Number 80 is normally used. Change the data if necessary. Enter the net mask if DHCP server is not used. Enter the gateway address if DHCP server is not used. Displays the MAC address (Media Access Control Address), which is proper to the network device. This function may be needed when to use the DHCP server. Display of host name and setting DHCP client function Display of IP address and setting Display and setting of the port number for connection with the Web browser. Display of net mask and setting Display of gateway address and setting Display of MAC address • Before using the DHCP server, make sure the DHCP server is already functioning. • For details of IP address, net mask, and gateway, ask the network administrator. Initial setting of network module (continuing) Accessing from the Web browser Activate the Web browser in the personal computer. Enter the IP address set by the projector into the URL input field of the Web browser. Enter “user1” in the user name field and enter “panasonic” (lower case) in the password field. Press OK and the top page will appear. Note
93 Top page Network setting button Click this item, and a network setting page for IP address and other items appear.Control button Click this item, and a projector control page appears. E-mail setting button Click this item, and an E-mail setting page appears. Link button to time setting If time setting goes wrong immediately after setting time, the battery must be replaced. Link button to network setting Link button to password changing Network setting page Update button This button cannot be used with this unit. Monitor information button Click this item, and the status of the projector is displayed.
94 How to use network module (optional) Network setting page Select ON to enable the DHCP client function. Enter the IP address if DHCP server is not used. Enter the port number. Normally use the value of 80 as indicated. Enter the net mask if DHCP server is not used. Enter the gateway address if DHCP server is not used. Enter the projector name. Enter this field when the host name is required such as when to use the DHCP server. Advanced control page On-screen status is displayed, even if the on-screen of projector is set to off. This button updates the on-screen description on the right of the control page with the latest information. Pressing these buttons controls the projector and updates the on-screen description on the right of the control page when control is finished.
95 Monitor information page Displays the status of input slot. Displays temperature of projector exhaust. Displays the lamp lit hours. Displays used hours of the projector. Displays self-diagnosis information. Displays the firmware version of the projector main unit. Displays the type of projector. Displays temperature of projector’s intake air. Displays temperature inside the projector. E-mail setting page • This page allows the user to send mail to up to two mail addresses automatically. Select “Enable” to use the E-mail function. Enter the IP address of the E-mail server (SMTP). The user can enter the location of, for example, the installed projector so that the recipient may easily identify the originator of the E-mail. (maximum 63 characters) Enter the E-mail address of the projector. (maximum 63 characters) The user can modify the minimum time interval of temperature warning mail. The default value is 60 minutes. In this case, the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again. The user can modify the threshold temperature for sending temperature warning mail. If the temperature rises above the set value, control sends temperature warning mail. Enter the E-mail address of your desired recipient. (Continued on next page)
96 E-mail setting page (continuing) When all entries are complete, press the Submit button.To use two E-mail addresses, enter the E- mail address of the destination recipient. Select the conditions for sending E-mail. Error: an error is detected by self-diagnosis. Warning LAMP1: remaining lamp service time has reached the value set in the field on the right. Warning LAMP2: remaining lamp service time has reached the value set in the field on the right. Warning input air Temperature: temperature inside the projector has reached the value set in the above field. Warning output air Temperature: exhaust temperature has reached the value set in the above field. Select the conditions for sending E-mail. Error: an error is detected by self-diagnosis. Warning LAMP1: remaining lamp service time has reached the value set in the field on the right. Warning LAMP2: remaining lamp service time has reached the value set in the field on the right. Warning input air Temperature: temperature inside the projector has reached the value set in the above field. Warning output air Temperature: exhaust temperature has reached the value set in the above field. How to use network module (optional)
97 Returning the network module setting back to the factory setting Using the following procedure, the user can return all settings of network module such as IP address, password and Email setting to the factory setting. Procedure of setting Using the remote control “POWER” button, switch the power supply of the projector to standby state. Using something with a thin tip, press and hold the FUNCTION switch for three seconds. The ON-LINE lamp blinks and turns off after 30 seconds or so. Turn off MAIN POWER. Turn on MAIN POWER while holding the FUNCTION switch pressed using something with a thin tip. When the ON-LINE lamp lights up, the operation is complete. • Do not use a pencil or other fragile thing to depress the function switch.Note Image file control page Folder selection button This button specifies the folder to store the image data. Display selection button This button selects the format of listing of images stored in the network module. Transmission button Transfers an image stored in the PC to the network module. Display button Displays an image stored in the network module. Delete file button Deletes an image stored in the specified folder of the network module. • The format of images is compatible with BMP, JPEG and PNG. However, some images may not be displayed because of more than one format existing in JPEG and PNG images. • Pixels of an image correspond to horizontal 1 024 dots times vertical 768 dots. • The system can display 65 536 colors. Note
98 Indication of monitor lamp Three monitor lamps are provided at the top of main unit front to inform the user of the lamp replacement time and unusual internal temperature. These lamps indicate the degree of abnormality by combination of blinking and/or lighting lamps. Turn off the power and take the proper measure according to the table below. Lamp 2 monitor (LAMP2) Lamp 1 monitor (LAMP1) Temperature monitor (TEMP) TEMP LAMP1 LAMP2POWER • Be sure to observe the procedure (How to turn “ON” and “OFF” the power supply) on page 39–40 when performing power supply operation to take a measure to the indication of temperature monitor (TEMP) lamp and lamp monitor (LAMP) lamp.Attention Name of monitor lampLamp indicationInformation High temperature inside. (WARNING)• Check if the ventilation port is blocked. • Is the room air temperature too high? • Check the air filter for clogging. Warm-up status • Did you turn on the power when the ambient temperature was low (approx. 0 °C)? Checkpoint • Wait about five minutes in the current status. • Install the unit in a location having an ambient temperature from 0 to 40 °C. • Remove the object that is blocking the ventilation port. • Move the projector to a temperature of 0 to 40 ˚C and the humidity of 20 to 80% (no condensation). • Turn off the MAIN POWER switch using the procedure on page 40 and clean the air filter (refer to page 99). Lighting in red (lamp unit ON) Remedial measure Blinking in red (2 times)High temperature inside (Standby condition) Blinking in red (3 times)Cooling fan has been stopped. • Turn off the main power supply (MAIN POWER) switch in the procedure shown on page 40 and consult the distributor. • This lamp monitor lights up when the lamp unit used hours have reached 1 300 hours (3 800 hours when Long Life Lamp Units are used). Request the dealer to replace the lamp unit. • Wait until the lamp has cooled off, and then turn on the power. • Did you notice a “REPLACE THE LAMP” message on the screen when turning on the projector power supply. • Did you turn the power back on immediately after turning it off? • Turn off the MAIN POWER switch using the procedure on page 40 and consult the dealer. • Some error has arisen in the lamp circuit. • Check for fluctuation (or drop) in the source voltage. Indicates the time for replacing the lamp unit. Error is detected in the lamp circuit. Lighting in red Blinking in red (3 times) Temperature monitor TEMP Lamp monitor LAMP1 LAMP2
99 Cleaning and replacement of air filter Turn off the main power and remove the power plug from the receptacle. Turn off the power supply observing the procedure (How to turn “OFF” the power supply) on page 40 and then remove the power plug. Dismantle the air filter. Put a hand in the bottom of the air filter, take out the filter from the main unit while pulling toward yourself. Clean the air filter. Suck off deposited dust with a vacuum cleaner. Mount the air filter. Set the air filter and then mount the filter in the reverse order to step . Air filter • Be careful not to suck in the air filter itself. • The air filter must be fitted in place when using the projector. Using the projector without the air filter fitted inside, dirt and dust are sucked into the projector, causing failure. Attention Attention • If cleaning cannot remove the dust completely, then it is a sign to replace the air filter. Consult the dealer. In addition, when the lamp unit is replaced, also replace the air filter. Note If too much dust is deposited in the air filter, temperature inside the main unit will rise and the temperature monitor (TEMP) lamp blinks, eventually turning off the power supply. Clean the air filter section once every 100 hours or so as a guideline depending on the location of projector operation. Procedure of cleaning
100 Replacement of lamp unit Precautions on lamp unit replacement Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, explosion might result. A used lamp unit may burst if it is handled violently. For disposition of used lamps, request an industrial waste disposal contractor. Do not reset the cumulative time, except when the lamp unit has been replaced with a new unit. If you continue to use a lamp after the replacement time, the lamp may break. Philips screwdriver is necessary when replacing a lamp unit. Take care not to slip your hand when using a screwdriver. • A lamp unit is an optional part. Contact the dealer. Replacement Lamp Unit model No.: ET-LAD7700 (single bulb), ET-LAD7700W (double bulbs) Rating: 300W Long Life Lamp Unit model No.: ET-LAD7700L (single bulb), ET-LAD7700LW (double bulbs) Rating: 160W • Other lamps than specified above cannot be used. Be sure to use the specified lamp.AttentionThe lamp used for the light source has its due life. The life of light source lamp used in the main unit is 1 500 hours 1(when lamp output is HIGH and lamp selection is DUAL). However, it may happen that the lamp becomes dead (will not light) by the time of 1 500 hours 1depending on the characteristics of individual lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals between previous lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare bulb. If your lamp unit is not replaced after 1 300 hours 2 (with the lamp output set at “HIGH”), power supply will be turned off automatically at the time of 1 500 hours1, entering a standby state. After 1 500 hours1of initial lighting, power supply is turned off automatically about 10 minutes later, entering a standby state even if it is turned on again. Indication after 1 300 hours2 (with the lamp output set at HIGH) When lamp unit used hours have reached 1 300 hours2, lamp monitor (LAMP1 or LAMP2) light up including standby state. Further, an on-screen indication will appear for about 30 seconds as shown in the diagram on the right, recommending replacement of lamp unit. (The indication on the below diagram will disappear after about 30 seconds or when either control button on the rear of main unit or remote control button is operated.) After the time of 1 500 hours 1, the on-screen indication will not disappear unless the menu (MENU) button is operated. REPLACE THE LAMP CAUTION Wait until the lamp is cooled sufficiently before replacing the lamp unit. Timing of lamp unit replacement 1 This time period is 4 000 hours when Long Life Lamp Units are used. 2 This time period is 3 800 hours when Long Life Lamp Units are used.