Page 71
71 Function menus(continued) Different kinds of settings and information can be stored or retrieved from an SD memory card. When (CARD) is pressed on the screen while the button is held down, the function menu shown below is displayed. [MENU/ERROR LOG/MULTI CUE] SYSTEM MENU/SETUP MENU/ 50PIN ASSIGN MULTI CUE ERROR LOG zThe available capacity on an SD memory card is in the range from 8 MB to 2 GB. zAn SD memory card must be formatted on the unit. zAn SRAM card cannot be used. zAn SDHC memory...
Page 72
72 Function menus (continued) (continued) [MENU/ERROR LOG/MULTI CUE] zThe SD memory card is capable of storing and retrieving the settings from the SETUP MENU (Current, USER1 to USER4)/SYSTEM MENU, the registered contents of 50PIN ASSIGN, the registered points of MULTI CUE, and the contents of the ERROR LOG. zTitles can be provided for all the data files, and when the files are saved or loaded, the titles are also copied at the same time. zThe file lock prevents the files on an SD memory card from...
Page 73
73 Function menus(continued) (continued) 5File overwrite inhibit facility The file lock prevents the files on an SD memory card from being overwritten. z Locking a file Select the file to be locked, and press (LOCK). z Unlocking a file Press (LOCK) again. The locked or unlocked status is displayed in the file status. [±: Unlocked status, µ: locked status] F5 F5 Function button/ item Switching method SettingCorresponding setup menu itemDescription of setting F1 FORMATF+Press ______ Formatting SD...
Page 74
74 Function menus (continued) Using the front panel controls and on-screen menus, functions are registered into the input pins of the parallel remote (50PIN) connector and the statuses are registered into its output pins. When (50P IN) or (50P OT) is pressed while the button is held down on the menu, the function menu shown below appears, and functions can be registered or deleted. Registered item names Setup menu items and 50PIN special menu items can be registered in the parallel remote...
Page 75
75 Function menus(continued) (continued) Registering functions in the input pins/Active inputs Registering functions in the output pins/Active outputs 1Selecting the 50-pin connector pins Turn the ADJ dial to move the selection marker and select the pin of the 50-pin connector into which the menu item is to be registered. 2Entering the 50-pin connector pins Press the ADJ dial. The entered 50-pin connector pin display is highlighted. 3Selecting the menu item Turn the ADJ dial and select the menu item...
Page 76
76 Function menus (continued) (continued) Special OUT menu list No. SUPER DISPLAYDescription of setting C00 EJECTEJECT status C01 STBY ONSTANDBY ON status C02 CUECUE-UP completed status C03 STILLSTILL status C04 PANEL STOPStatus in which the front panel STOP button is pressed down C05 PRE CTLStatus of whether to inhibit overwrite during normal recording C06 422 REM ON9-pin connector function status C07 REMOTE50-pin connector function status C08 REC INH1Recording inhibit status 1 C09 REC INH2Recording...
Page 77
77 Function menus(continued) (continued) The statuses established by a multiple number of pins in the special OUT menu list are displayed. Pin status “1” signifies “active low” and “0” signifies “open.” Error statuses TC input statuses Tape recording inhibit statuses Recording inhibit statuses Down-conversion statuses Up-conversion statusesUp-conversion down-conversion statuses C22 ERR0C23 ERR1C24 ERR2Error status 0 0 0 SERVO NOT LOCKED (priority level 1) 0 0 1 SERVO LOCKED (priority level 4) 0 1 0...
Page 78
78 Function menus (continued) (continued) Flow of registration 50P IN/OUT ASSIGN function buttons Open the screen.Status in which registered 50-pin connector pin selection is enabled Close the screen. F6 (EXIT) Status in which selected 50-pin connector pin menu item selection is enabled Press the ADJ dial. Status in which selected menu item setting selection is enabledTurn the ADJ dial. Turn the ADJ dial. F4 (one pin reset) F i F4 (all pins reset) F5 (settings entered)Turn the ADJ...
Page 79
79 Function menus(continued) (continued) 50-pin assignment factory settings “__” denotes that nothing is subject to control or to a status. zFor a command, input TTL level signals; for an active low edge, input an electrical signal of 100 ms or more. zFor a status, a maximum open collector and sink current of 6 mA is output. Pin no. I/O Setting item 1IREC 2IPLAY 3IFF 4IREW 5ISTOP 6I __ 7I__ 8I422 REMOTE ON 9I422 REMOTE OFF 10 ILOCAL ENABLE 11 IEJECT 12 IIN SET 13 IREC INH ALL 14 IREC INH PRE 15...
Page 80
80 System menus The underlining (__) denotes the factory setting mode. Video output signal adjustments The control matrix for the adjustments is shown in the table below.External encoder remote controller: Only adjustments of the external encoder remote controller are performed. This unit Only adjustments of the setup menu items are performed. External encoder remote controller/this unit Adjustments can be performed from both the external encoder remote controller and setup menus. Use the AJ-ER50,...