POWERIndication
THERMALPress the ALARM RESET button to can-
cel the warning status. The unit will be in
the error half-reset/error reset condition.
If thermal errors occur frequently, the
unit may be malfunctioning. Contact the
dealer. Warning Thermal error of the unit or the optional
extension unit has been detected.
Press the ALARM RESET button to can-
cel the error/warning status. The unit will
be in the error half-reset/error reset con-
dition. Initialize the DVD-RAM disk.
(Refer to page 56.) When...

Page 62

62
Press the ALARM RESET button to can-
cel the error status. The unit will be in
the error half-reset condition. Contact
the dealer.
Press the ALARM RESET button to can-
cel the error status. The unit will be in
the error half-reset condition. Contact
the dealer. M-FAIL
R-FAILError
ErrorFailed to recover mirroring. 
Failed to recover RAID. Indication Status Description Solution
* : Camera number
# : Partition number (Refer to page 15.)
nn : Available disk space (percentage)
n : COPY port number to which...

Page 63

63
OPERATION USING A PC
It is possible to perform the settings or operate the unit
using a web browser installed on a PC when this unit is
connected to a network.
The available features and the system requirements of a
PC are as follows.
Refer to the Network Operating Instructions (PDF) on the
provided CD-ROM.
 Features
It is possible to operate this unit using a web browser in
much the same way as using the buttons on the front panel
of this unit.
The following functions are available when using a PC...

Page 64

64
System controller
OPERATION OF THE UNIT IN THE CASCADE CONNECTION
When connecting multiple units (up to 4 units) in the cas-
cade connection, it is possible to monitor images from all
of the WJ-HD316A/309A in the cascade connection using
a monitor. It is necessary in advance to perform the set-
tings to operate the unit in the cascade connection. Refer
to a system administrator for further information.
Important:
• Video output signal will not be supplied from the MONI-
TOR (VGA) connector when...

Page 65

65
Operation using the system con-
trollers
When using the system controller to which the unit
number 001 is allocated 
It is possible to operate all of the WJ-HD316A/309A in the
cascade connection using an optional PS·Data compatible
controller by designating a unit number. When monitor 2 is
selected, it is possible to display images from any unit
which will be displayed on monitor 2 connected to the first
unit. 
(*1)
When monitor 1 is selected, images will be displayed on
monitor 1 connected to the...

Page 66

66
MANAGEMENT OF USERS/HOSTS
It is necessary in advance to register users and PCs (hosts) who access this unit via a network such as a LAN.
Up to 32 users and 8 hosts can be registered.
The following information can be registered as user information and host information.
For the set items above, the unit will work differently depending on whether the unit is operated directly or operated via a net-
work as follows.
When the unit is operated directly
Operate using the monitor connected with this unit....

Page 67

67
Notes:
• When a user is operating this unit using a PS·Data compatible controller, this user can log in automatically as a PSD user
set for PSD User of System on the SETUP MENU.
• When a user logged into this unit using a PS·Data compatible controller and didn’t operate the unit for around 2 minutes,
this PSD user will be forced to log out.
• It is possible to log in as the user who has already logged in regardless of priority.
When the unit is operated using a PC via a network
Operate using a PC via...

Page 68

68
OPERATING THE UNIT FOR THE FIRST TIME
Important:
When connecting an optional extension unit (the WJ-
HDE300 series), turn on the power of the extension unit
before turning on the power of this unit.
zTurn on the POWER switch.
xPress the SET button when the system check
complete window is displayed.
The HDD DISK MENU window will be displayed.
Perform the settings with this menu according to your
needs.
Refer to page 143 for further information.
After completing the settings, press any button to close...

Page 69

69
Preparation for maintenance (HDD
replacement, installation, etc.)
When maintaining (HDD replacement, installation, etc.)
without turning the power of the unit off, carry out the follow-
ing operation after setting the HDD SAFETY MODE to ON.
(The default setting is OFF.)
This can be set on the Disk Info menu of Maintenance.
Refer to page 135 for further information.
Important:
After completing the installation or the maintenance, set
the HDD SAFETY MODE to OFF.
Do the following before starting...

Page 70

70
The camera selection buttons (1 - 16 for the WJ-HD316A, 1
- 9, 0 for the WJ-HD309A) will light green and go off (for 2
seconds each) alternately.
The following window will be displayed after around 30 sec-
onds.
Start maintenance after this window is displayed.
The procedures are different between the replacement of
the hard disks and the installation of the unit (rack mount-
ing/unmounting).
Refer to the following descriptions.
When the system check has been completed, the HDD