11(EN) Menu items (1 to 13) 1Basic instructionsExplains the basic operations. • Press ◄ ► to turn the page.P. 8 2FLAP*Sets fl aps for each indoor unit.P.12 3Lock indiv. fl ap*Fixes the fl ap of a specifi c air outlet.P.13 4ON/OFF timerSets the ON/OFF timer P.14 5Weekly timerSets the operation schedule on a daily basis.P.15 6Filter info*Confi rms and resets the time to fi lter cleaning.P.20 7Outing function Prevents the room temperature from increasing to much (or decreasing too much) when no one is the room.P.31 8Quiet operation*Performs quiet operation for outdoor units.P.22 9Power consumption monitor * Confi rms the power consumptions on a daily, weekly or yearly basis.P.23 10Energy saving The energy saving functions shown on the right can be set individually aside from the (Energy saving) button. 11Initial settings 12Ventilation* Sets ventilation operation including the heat exchange ventilation unit.P.38 13Setting listConfi rms the meanings of setting information icons.P.39 No. 10 [Energy saving] details Temp auto returnRestores the temperature after the set time has elapsed even if the temperature is changed.P.24 Temp rangeRestricts the temperature range that can be set.P.25 Auto shutoffSets the auto shutoff timer.P.26 Schedule peak cut Determines the time zone for the energy saving operation.P.28 Repeat off timerStops operation after a certain period of time each time operation is performed.P.30 No. 11 [Initial settings] details ClockSets the present date and time.P.33 Clock typeSets the type of clock display.P.33 Controller nameNames the remote controller.P.34 Operation lockLocks the button operations.P.33 Touch soundTurns the operation sound ON/OFF. P.35 ContrastSets the screen contrast. BacklightSets the backlight brightness of the screen. Language Sets the display language for the top screen. Password change Sets the administrator password.P.36 Temp sensor Sets whether to use the temperature sensor of the remote controller or the indoor units.P.37 Main/sub Set this when 2 remote controllers are connected.P.37 Vent output Interlocks the ON/OFF of the air conditioner and ON/OFF of the fan.P.37 Contact addressConfi rms the contact address and telephone number for servicing.P.37 * Depending on the model, some menus cannot be used. The following display appears. The administrator password is required for setting. (P.36)
12(EN) Flap Setting for Each Indoor Unit FLAP When setting fl aps for each indoor unit • Flaps of all air outlets of 1 indoor unit face the same direction. 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [FLAP]. ▲ ▼ → 3 Select the indoor unit to set. ▲ ▼ → ► • ALL: All units connected to the remote controller e.g. (unit) ALL → 1-1 → 1-2 to 1-8 4 Select the fl ap direction. ▲ ▼ → (Press 2 times to fi nish.) • Pressing ▲ or ▼ during swing can stop the fl ap at your preferred position. • Pressing ▲ or ▼ while swing is stopped sets the fl ap at the specifi ed position. When ▲ is pressed When ▼ is pressed • 3-level adjustment is possible for Cool and Dry mode. Swing e.g. unit 1-1 e.g. unit 1-3
13(EN) Flap Setting for Each Air Outlet Lock indiv. fl ap When setting the fl ap for each air outlet individually according to the room condition • Even if the fl ap setting of all indoor units (P.9) or each indoor unit (P. 12) is changed, the fl ap directions set here are not changed. 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Lock indiv. fl ap] ▲ ▼ → 3 Select the indoor unit to set. ▲ ▼ → ► e.g. 1-1 → 1-2 to 1-8 4 Select the air outlet. ▲ ▼ → ► • The air outlet No. changes according to the installation direction. Check by actual operation. 1 2 34 5 Select the fl ap direction. ▲ ▼ → (Press 2 times to fi nish.) • Although is also displayed in Cool and Dry mode, the actual direction is . * For types other than the 4-way cassette type, the following display appears and this function cannot be used. Swing Unlock
14(EN) Timer Reservation ON/OFF timer This turns ON/OFF at the specifi ed time. (e.g. Turning ON/OFF after 3 hours) ONOFF 3 hours OFFON Set3 hoursOperation stopOperation stop SetSet • Use OFF timer for example when: Reducing electric consumption while sleeping • Use ON timer for example when: Operating the air conditioner according to the meeting start timing 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [ON/OFF timer]. ▲ ▼ → 3 Select the timer type ▲ ▼ → • Select [OFF timer] or [ON timer]. 4 Select [Set]. ▲ ▼ → • To set the timer to OFF, select [Unset]. 5 Set the time. hour minute ▲ ▼ → ► → ▲ ▼ → → → (Press 2 times to fi nish.)• Upper limit: Stops in 72 h. (by the 30 minutes) Note • If ON timer and OFF timer are set to the same time, priority is given to OFF timer, and ON timer cannot be used.
15(EN) Timer Reservation Weekly timer overview You can set a weekly operation schedule. • The operation ON/OFF schedule or temperature setting schedule can be set\ by setting the day and time (e.g. Setting the operation start time to 8:00\ a.m. from every Monday to Friday.). How to set (Overview) (See P.16 for setting procedure) • Select “Day” • Select “Time” * Select “Operation” • Select “Temperature” (Only for operations other than ON/OFF) *Operation • ON: Starts operation with the temperature set last. • OFF: Stops operation. • ON & TEMP: Starts operation with the speci fi ed temperature. • TEMP: Sets the temperature to the specifi ed temperature during operation. Combination examples 1. Stop operation earlier on “No-overtime work day” 8:00 17:00 8:00 22:00 ON ON OFFON Weekday No-overtime work day • The setting registered for 1 day can be copied to other days. (P.19) 2. Set the temperature higher after the fi xed time. 8:0022:00 17:00ON (26 °C) (28 °C) ON & TEMPOFF TEMP 3. Stop operation during lunch break. 8:00 22:00 12:45 12:00ON ON OFF OFFOFFONON 4. This Thursday is a holiday.The timer can be disabled only for the speci fi ed days with the registered schedules kept. (P.16) • Disable ( ) the timer of the specifi c Thursday which falls on a holiday. • Enable ( ) the timer after the holiday is over.
16(EN) Timer Reservation Weekly timer New registration• e.g. Start operation with 26 °C at 10:00 a.m. on every Sunday. 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Weekly timer]. ▲ ▼ → 3 Enable the Weekly timer. ▲ ▼ → ◄ ► → • Select the item with ▲▼ and select [] (enable)/[](disable) with ◄ ►. 4Select [] for all days when the timer is used. ◄ ► → ▲ ▼ → (Repeat)• Select the days with ◄ ► and select [] (enable)/[] (disable) with ▲ ▼. 5 Select the day for the timer setting. ◄ ► 6 Select the fi eld to register the timer setting. ▲ ▼ → • Up to 8 settings are available for each day. • After registration, the items are arranged in time series automatically.
17(EN) 7 Set the start time for the timer operation. hour minute ▲ ▼ → ► → ▲ ▼ → • 0:00 to 23:59 8 Select the timer operation. ▲ ▼ → • Types of timer operation ON: Starts operation with the temperature set last. OFF: Stops operation. ON & TEMP.: Starts operation with the specifi ed temperature. TEMP.: Sets the temperature to the specifi ed temperature during operation. 9 Set the temperature. ▲ ▼ → (Only for operations other than ON/OFF) 10 Confi rm the setting content. Confirm and press . (Press 2 times to fi nish.) To register additionally Repeat from step 6 without pressing . To copy the setting content to other days (P.19) To set the timer to OFFStarting with step 1, select [-] in step 3 and press 2 times. To set the timer to OFF for specifi ed days after registration (national holidays, etc.) Starting with step 1, set [] for OFF days in step 4 and press 2 times.
18(EN) Timer Reservation Weekly timer continued Change/Delete 1 After steps 1 to 4 on page 16, select the day to change or delete. ◄ ► 2 Select the schedule to change or delete. ▲ ▼ → 3 Select [Change] or [Delete]. ▲ ▼ → 4 Perform [Change] or [Delete] as follows. • To change the setting, following steps 7 to 10 on page 17, set the time, timer operation and temperature and confi rm the content. • To delete the setting, select [YES]. ◄ ► → → (Press 2 times to fi nish.) To change or delete settings repeatedly: Repeat from step 1 without pressing . Note To delete all schedules of selected days 1Select the day in step 1 above and press . 2Select [Delete all: ] with ▲ ▼ and press . 3Select [YES] with ◄ ► and press .
19(EN) Timer Reservation Weekly timer continued Timer copyThe registered schedule can be copied to other days. This is convenient to apply the same schedule to multiple days. 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Weekly timer]. ▲ ▼ → 3 Select [Timer copy]. ▲ ▼ → 4 Select the copy source day. ◄ ► → 5Select [] for all copy target days. ◄ ► → ▲ ▼ → • Select the days with ◄ ► and select [] with ▲▼. • [ ]: Copy source 6 Select [YES]. ◄ ► → → (Press 2 times to fi nish.)
20(EN) Filter Information 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select the item to set. ▲ ▼ → Filter information 3 Select [Next fi lter cleaning time]. ▲ ▼ → 4 Confi rm the operation time to the next cleaning. (Press 2 times to fi nish.) When cleaning is immediately necessary The screen shown on the right is displayed. Clean the fi lter. (See operating instructions of the indoor unit.) After the fi lter is cleaned Select [Filter sign reset] in step 3 above and select [YES]. ◄ ► → → (Press 2 times to fi nish.) (The fi lter cleaning time count is reset.)