Page 21
21(EN) Note • Depending on the model, [Filter info] cannot be used. In this case, a message is displayed as shown on the right. • When the cleaning time comes, the icon shown on the right appears on the top screen.
Page 22
22(EN) Quiet Operation/Power Consumption Monitor 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select the item to set. ▲ ▼ → Quiet operation 3 Enter the password. ▲ ▼ → ► → (Repeat) 4Set [Select enable/disable] to []. ▲ ▼ → ◄ ► • Select the item with ▲ ▼ and select []/ [] with ◄ ►. 5 Select [Quiet time]. ▲ ▼ → 6 Set the time to perform quiet operation. ▲ ▼ → ► → → (Repeat)(Press 2 times to fi nish.)
Page 23
23(EN) Power consumption monitor 3 Select the period to display. ▲ ▼ → 4 Confi rm the information. (Press 2 times to fi nish.) Note • Depending on the model, [Quiet operation] and [Power consumption monitor] cannot be used. In this case, a message is displayed as shown on the right. • Using the quiet operation function may deteriorate the performance to reduce the operation sound. • The power consumption shows an approximate calculation result, which may differ from the measurement result...
Page 24
24(EN) Energy Saving Temp auto return Restoring the changed temperature to the originally set temperature automatically after a specifi ed time elapses. (e.g. Only when a guest comes) Temp range Restricting the temperature range that can be set. (Temperatures outside the range cannot be set.) 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Energy saving]. ▲ ▼ → 3 Select the item to set. ▲ ▼ → Temp auto return 4Select...
Page 25
25(EN) Temp range 4Select the item and set to []. ▲ ▼ → ◄ ► → 5 Set the temperature range. ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to fi nish.) Setting range • Cool/Dry: 18 °C to 30 °C • Heat: 16 °C to 30 °C • Auto: 17 °C to 27 °C To set in series Repeat from step 4 without pressing . Note • Temp auto return When [Return type] is set to [Saving], this functions only when the temperature set in step 5 saves more energy than the changed temperature. e.g. When Cool 26 °C is set and the...
Page 26
26(EN) Energy Saving Auto shutoff When the operation is stopped at a specifi ed time (e.g. closing time) and resumed afterwards, this function detects the operation status at regular time intervals and stops operation automatically. Detect the operation status at regular time intervals and stop the operation automatically. (e.g. 60 min) ON OFF 21:00 22:08DetectDetect Detect 23:009:00 60 min 60 min 60 min Closing timeOpening time Auto shutoff in effect Leaves the shop without turning off A/C.If...
Page 27
27(EN) Stop time Time to stop operation (Time when Auto shutoff is activated) 5 Set. hour minute ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to fi nish.) End time Time when Auto shutoff stops 5 Set. hour minute ▲ ▼ → ► → ▲ ▼ → → (Press 2 times to fi nish.) Timer Time interval to detect operation status after [Stop time] 5 Set. ▲ ▼ → → (Press 2 times to fi nish.) • 10 min to 180 min (by the 10 min)
Page 28
28(EN) Energy Saving Schedule peak cut This reduces the operation capacity for the specifi ed time period. 1 Display the menu screen. To return to the last screenPress . To return to the top screenPress 2 times. 2 Select [Energy saving]. ▲ ▼ → 3 Select [Schedule peak cut]. ▲ ▼ → 4 Enter the password. ▲ ▼ → ► → (Repeat) 5Set [Select enable/disable] to []. ▲ ▼ → ◄ ► 6 Select [Set schedule]. ▲ ▼ → 7 Change the setting. Select the fi eld to register. ▲ ▼ → Large Small 11:00 13:00 16:00...
Page 29
29(EN) 8 Set the start time and end time. ▲ ▼ → ► → ▲ ▼ → (Repeat) 9 Select the operation capacity. ▲ ▼ → → (Press 2 times to fi nish.) To set in seriesRepeat from step 4 without pressing . To change• Select the fi eld to change in step 7 above. • Select [Change]. ▲ ▼ → • Following the above steps 8 to 9, select the start time, end time and operation capacity. To delete• Select the fi eld to delete in step 7 above. • Select [Delete]. ▲ ▼ → • Select [YES]. ◄ ► → → (Press 2 times to fi...
Page 30
30(EN) Energy Saving Repeat off timer This stops operation after a certain period of time each time operation is performed. (e.g. When forgetting turning off) 1 Display the menu screen. To return to the previous screenPress . To return to the top screenPress 2 times. 2 Select [Energy saving]. ▲ ▼ → 3 Select [Repeat off timer] and set to [ ]. ▲ ▼ → ◄ ► → 4 Set the timer to stop. ▲ ▼ → → (Press 2 times to fi nish.) • 10 min to 180 min (by the 10 min) ON OFF 60 min Finishes working...