Page 11

11
Features and Installation
9
5
5
5
(Type A)
(Type A)
11
Shipping 
Screws
1234
811
12
9765
10
Lower guide
PREPARATION OF CHASSIS
1. Remove the screws which fasten the cabinet
at both sides and at the back.
2. Slide the unit from the cabinet by gripping the
base pan handle and pulling while bracing the
cabinet.
3. Cut the window sash seal to the proper
length. 
Peel off the backing and attach the FOAM-PE
to the underside of the window sash.
4. Remove the backing from the top upper guide
FOAM-PE 
and...

Page 12

12
Features and Installation
Upper Guide
Window SashWindow sill
Front Angle
Upper guide
Frame Curtain
1
Foam-pe8
Foam-pe11
Cabinet
INDOOR OUTDOOR
INDOOR OUTDOOR
Sash track
Front AngleCabinet
About 
1/2 (12.7mm) About 
1/2(12.7mm)
Sill Support2
Nut4Bolt3
Screw (Type B)6
Screw (Type B)6
Sill support2
Sill support2
Screw (Type A)5
1. Open the window. Mark a line on
center of the window sill(or desired air
conditioner location).
Carefully place the cabinet on the
window sill and align the center mark
on the...

Page 13

13
Features and Installation
Type C7
Screw
ScrewPower cord
Foam-Strip8
Window locking bracket10
9. Attach each Frame curtain to the window
sash using screws 
(Type C). (See Fig. 6)
CAUTION: DO NOT DRILL A HOLE IN THE
BOTTOM PAN.
The unit is designed to operate
with approximately 1/2 (12.7mm)
of water in bottom pan.
10. Slide the unit into the cabinet. (See Fig. 7)
CAUTION: For security purpose, reinstall
screws at cabinets sides.
11. Cut the foam-strip 
to the proper length
and insert between the upper...

Page 14

14
Features and Installation
Do not under any 
circumstances cut 
or remove the 
grounding prong 
from the plug.
Line Cord Plug Use Wall Receptacle Power Supply
Power supply cord with
3-prong grounding plugStandard 125V, 3-wire grounding
receptacle rated 15A, 125V ACUse 15 AMP, time
delay fuse or circuit 
breaker.
Electrical Data
USE OF EXTENSION CORDS
Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you
wish to use an extension cord, use a CSA...

Page 15

15
Features and Installation
PREFERRED METHOD
Ensure proper ground
exists before use
TEMPORARY METHOD
Adapter plug
Receptacle coverMetal screw
Electrical Safety (Applies to USA and Puerto Rico)
IMPORTANT
(PLEASE READ CAREFULLY)
FOR THE USERS PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED
The power cord of this appliance is equipped with a
three-prong (grounding) plug. Use this with a
standard three-slot (grounding) wall power outlet
(Fig. 12) to minimize the hazard of electric shock.
The...

Page 16

16
Before you call for service...
Before you call for service...
Troubleshooting Tips Save time and money! 
Review the chart below first and you may not need to call for service.
Normal Operation
• You may hear a pinging noise caused by water being picked up and thrown against the condenser
on rainy days or when the humidity is high. This design feature helps remove moisture and improve
efficiency.
• You may hear the relay click when the compressor cycles on and off.
• Water will collect in the base pan...

Page 17

17
Memo 

Page 18

18
Instructions de fonctionnement
Instructions dinstallation
Conseils de dépannage
Mesures de sécurité
Mesures de sécurité
Mesures de sécurité  ........19
Instructions de
fonctionnement
Les commandes... .............21
Télécommande..................22
La ventilation .....................23
Ajuster la direction d’air .....23
Comment utiliser le tuyau
d’évacuation ......................23
Nettoyage et entretien
Nettoyage du filtre à air... ..24
Caractéristiques
Caractéristiques ................25...

Page 19

Mesures de sécurité
AVERTISSEMENT
19
Mesures de sécurité
Les instructions ci-après doivent être observées dans le but de prévenir tout risque de dommages corporels
ou matériels.
Lutilisation non conforme, résultant de la négligence des instructions, est susceptible de provoquer des
dommages corporels ou matériels dont la gravité est signalée par les indications suivantes :
AVERTISSEMENT: Ce symbole signale un risque de blessure grave, voire mortelle.
ATTENTION: Ce symbole signale un risque limité aux...

Page 20

20
Mesures de sécurité
ATTENTION!
Lorsque le filtre à air doit être
retiré, ne pas toucher les
parties métaliques de
lappareil intérieur.
• Vous risquez de vous blesser.
Ne pas nettoyer le
climatiseur à grande eau.
• Leau peut sinfiltrer dans
lappareil et affecter lisolement.
Cela peut également provoquer
une électrocution.
Assurer une ample
circulation dair dans la pièce
si un appareil de chauffage
est utilisé.
• En effet, loxygène sappauvrit
dans ces conditions dutilisation.
Lorsque lappareil doit...