Page 14
REMARKS B: BLUEP: PINK BR: BROWNR: RED BL: BLACKW: WHITE G: GREENY: YELLOW GRY: GRAYY/G: YELLOW/GREEN O: ORANGE Resistance of Indoor Fan Motor Windings MODELCS-XC9CK CS-XC12CK CONNECTIONCWA921060CWA921181 BLUE-YELLOW371.0Ω390Ω YELLOW-RED386.6Ω390Ω Note: Resistance at 20°C/25°C of ambient temperature. Resistance of Outdoor Fan Motor Windings MODELCU-XC9CK CONNECTIONCWA951088CWA951114 BLUE-YELLOW217.3Ω259Ω YELLOW-RED198.5Ω235Ω MODELCU-XC12CK CONNECTIONCWA951116 BLUE-YELLOW230Ω YELLOW-RED255Ω Note:...
Page 15
8 Operation Details 8.1. Indoor Fan Speed Control • Auto Fan Speed Control When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. • Manual Fan Speed Control Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote control. 15
Page 16
Cooling in operation according to Remote Control setting. Time Delay Safety Control (3 minutes) 7 minutes Time Save Control Starting Current Control Anti-Freezing Control • If the temperature of the indoor heat exchanger falls continuously below 2°C for 4 minutes or more, the compressor turns off to protect the indoor heat exchanger from freezing. The fan speed setting remains the same. • Compressor will restart again when the indoor heat exchanger temperature rises to 10°C (Recovery). 3 minutes...
Page 17
Automatic Fan Speed Mode Cooling Operation Time Diagram When Automatic Fan Speed is selected at Remote Control during cooling operation. • Fan speed rotates in the range of Hi to Me. • Deodorizing Control. 17
Page 18
Quiet Operation Control (For Cooling Mode or cooling region of Soft Dry Mode) • Purpose of this operation is to provide quite cooling operation compare to normal operation. • When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased 2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation. • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control. • Dew formation become severe at Quiet Lo cool, therefore...
Page 19
Time Delay Safety Control Starting Current Control Anti-Freezing Control Compressor Reverse Rotation Protection Control Automatic Fan Speed Mode 8.3. Soft Dry Mode Operation • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and then Soft Dry operation will start. • During Soft Dry operation, the Indoor Fan will operate at Lo- speed. • The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once...
Page 20
Soft Dry Operation Time Diagram Quiet Operation Control (For Dry region of Soft Dry Mode) 20