Panasonic Cs Xc9ckh Cs Xc12ckh Series Repair Manual
Here you can view all the pages of manual Panasonic Cs Xc9ckh Cs Xc12ckh Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
1 Features 2 2 Functions 3 3 Product Specifications 6 4 Dimensions 10 5 Refrigeration Cycle Diagram 12 6 Block Diagram 13 7 Wiring Diagram 14 8 Operation Details 15 8.1. Indoor Fan Speed Control 15 8.2. Cooling Mode Operation 16 8.3. Soft Dry Mode Operation 19 8.4. Air Circulation Mode Operation 21 8.5. Automatic Mode Operation 21 8.6. Random Auto Restart Control 21 8.7. Vertical Airflow Direction Control 22 8.8. Delay ONTimer Control 22 © 2003 Matsushita Industrial Corp....
Page 2
15 Exploded View 67 16 Replacement Parts List 68 17 Exploded View 69 18 Replacement Parts List 70 19 Electronic Circuit Diagram 71 19.1. REMOTE CONTROL 76 • High Efficiency • Compact Design • Comfort Environment − Ionizer control for generate negative ion in discharge air − Air filter with function to reduce dust and smoke − Wider range of horizontal discharge air • Auto Restart − Random auto restart after power failure for safety restart operation • Removable and Washable Front...
Page 3
2 Functions CHECK AUTOAU TO TEMP AUTOAU TOONOFF AUTOAU TODRYDRYFA NCOOLCOOL FA NAUTO AU TO RESET CLOCK MODE FAN SPEED OFFCANCEL ONSET12 3 TIMER OFF ON/ QUIETAIR SWINGAUTOMANUAL 2 Remote Control Operation OFF / ONOFF / ON Room Temperature SettingTEMP. Operation Mode Selection AUTOAutomatic Operation Mode COOLCooling Operation Mode DRYSoft Dry Operation Mode FANAir Circulation Mode MODE TIME Time / Timer Setting Hours and minutes setting. Clock Setting Current time setting. Ionizer Operation OFF / ON...
Page 4
Indoor Unit Ionizer Control Ionizer control for generate negative ion in discharge air. Indoor Fan Speed Control High, Medium and Low. Automatic Fan Speed Mode _Cooling : Fan rotates at Hi, Me and SLo speed. Deodorizing control is available. _Soft Dry : Fan rotates at Lo- speed. Deodorizing control is available. Automatic air swing and manual adjusted by remote control for vertical airflow. Manually adjusted by hand for horizontal airflow. Airflow Direction Control Automatic Operation Button Press for <...
Page 5
Outdoor Unit • To protect compressor from reverse rotation when there is a instantaneous power failure. 60 Secs. Forced Operation Control • Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal. Overload Protector • 2-Stage OLP to protect the compressor, (XC9CK). • Inner Overload Protector (XC12CK). Overload Protector will trip when – Temperature of compressor increases to 120°C. – High temperature or high current flows...
Page 6
3 Product Specifications UnitCS-XC9CKHCU-XC9CKH Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz Cooling CapacitykW (BTU/h)2.72 - 2.75 (9,280 - 9, 390) Moisture Removall/h (Pint/h)1.6 (3.4) Airflow MethodOUTLET INTAKE SIDE VIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)6.8 (240) - 6.8 (240)— Indoor Air (Me)m3/min (cfm)8.0 (280) - 8.0 (280)— Indoor Air (Hi)m3/min (cfm)9.9 (350) - 9.9 (350)32.2 (1,140) - 33.8 (1,190) Noise LeveldB (A)High 36 - 36, Low 26 - 26High 46 - 47 Power level dBHigh 49 -...
Page 7
Note: UnitCS-XC9CKHCU-XC9CKH Capillary TubeLengthmm—720 Flow Ratel/min—11.0 Inner Diametermm—1.5 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—30 µF, 370VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC • Specifications are subject to changewithout notice for further improvement. 7
Page 8
UnitCS-XC12CKHCU-XC12CKH Power SourcePhase, Voltage, CycleSingle, 220 - 240, 50 Hz Cooling CapacitykW (BTU/h)3.67 - 3.78 (12,530 - 12,900) Moisture Removall/h (Pint/h)2.1 (4.4) Airflow MethodOUTLET INTAKE SIDE VIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)7.3 (260) - 7.3 (260)— Indoor Air (Me)m3/min (cfm)8.7 (310) - 8.7 (310)— Indoor Air (Hi)m3/min (cfm)10.2 (360) - 10.2 (360)30.3 (1,070) - 31.3 (1,100) Noise LeveldB (A)High 39 - 39, Low 29 - 29High 48 - 49 Power level dBHigh 52 - 52High 62 - 63...
Page 9
Note: UnitCS-XC12CKHCU-XC12CKH Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—35 µF, 370VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC • Specifications are subject to changewithout notice for further improvement. 9