Panasonic Cs Xc9ckh Cs Xc12ckh Series Repair Manual
Here you can view all the pages of manual Panasonic Cs Xc9ckh Cs Xc12ckh Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 41
Applicable piping kit CZ-3F5, 7AEN (XC9CK) CZ-4F5, 7, 10AN (XC12CK) SELECT THE BEST LOCATION INDOOR UNIT • There should not be any heat source or steam near the unit. • There should not be any obstacles blocking the air circulation. • A place where air circulation in the room is good. • A place where drainage can be easily done. • A place where noise prevention is taken into consideration. • Do not install the unit near the doorway. • Ensure the spaces indicated by arrows from the wall, ceiling,...
Page 42
10.2.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section) 10.2.2. HOW TO FIX INSTALLATION PLATE The mounting wall is strong and solid enough to prevent it from the vibration. The centre of installation plate should be at more than 450 mm at right and left of the wall. The distance from installation plate edge to ceiling should more than 67 mm. From installation plate left edge to unit’s left side is 47 mm. From installation plate right edge to unit’s right is 73 mm. : : :For left...
Page 43
3. For the embedded piping (This can be used for left rear piping & left bottom piping also.) 43
Page 44
10.2.5. CONNECT THE CABLE TO THE INDOOR UNIT 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 5 (XC9CK, XC12CK) × 1.5 mm 2flexible cord, typedesignation 245 IEC 57 or heavier cord. • Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. • Earth lead wire shall be longer than the other lead wires as shown...
Page 45
HOW TO TAKE OUT FRONT GRILLE Please follow the steps below to take out front grille if necessary such as when servicing. 1. Set the vertical airflow direction louver to the horizontal position. 2. Slide down the two caps on the front grille as shown in the illustration below, and then remove the two mounting screws. 3. Pull the lower section of the front grille towards you to remove the front grille. When reinstalling the front grille, first set the vertical airflow direction louver to the horizontal...
Page 46
CUTTING AND FLARING THE PIPING 1. Please cut using pipe cutter and then remove the burrs. 2. Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe. 3. Please make flare after inserting the flare nut onto the copper pipes. (1)* *Connect the manifold gauge to the service port of 3-way valve. Measure the pressure.(2)* *Keep it for 5-10 minutes. Ensure that the pressure indicated on the gauge is the same...
Page 47
CHECK THE DRAINAGE • Open front panel and remove air filters. (Drainage checking can be carriedout without removing the front grille.) • Pour a glass of waterinto the draintraystyrofo am. • Ensure that water flows out from drain hose of the indoor unit. EVALUATIONOF THE PERFORMANCE • Operate the unit at cooling operation mode for fifteen minutes or more. • Measure the temperature of the intake and discharge air. • Ensure the difference between the intake temperature and the discharge is more than...
Page 48
10.3.7. OXYGEN TUBE CONNECTION Precautions duringoxygen tube connection 1. Tube allowable length and height difference is the same as pipes. 2. Tube should be pulled without folding it along the path of refrigerant pipe, providing sufficient allowance and cut to length. • If there is no allowance, tube length will contract when temperature changes and it may cause trouble. • On the other hand, tube length used without cutting and in the form of loop too should be avoided. 3. When the tube is passed...
Page 49
11 2-way, 3-way Valve 2-way Valve (Liquid Side)3-way Valve (Gas Side) WorksShaft PositionShaft PositionService Port ShippingCloseCloseClose (With valve cap)(With valve cap)(With cap) EvacuationCloseCloseOpen (Installation and(Counter-Clockwise)(Clockwise)(Push-pin) Re-installation) OperationOpenOpenClose (With valve cap)(With valve cap)(With cap) Pumping downCloseOpenOpen (Transferring)(Clockwise)(Counter-Clockwise)(Connected manifold gauge) EvacuationOpenOpenOpen (Servicing)With vacuum pump Gas...
Page 50
Required tools: hexagonal wrench, adjustable wrench, torque wrenches, wrench to hold the joints and gas leak detector. The additional gas for air purging has been charged in the outdoor unit. However, if the flare connections have not been done correctly and there gas leaks, a gas cylinder and the charge set will be needed. 1. Recheck the piping connections. 2. Open thevalve stemof the2-wayvalvecounter- clockwise approximately 90°, wait 10 seconds, and then set it to closed position. • Be sure to use...