Home > Panasonic > Air Conditioner > Panasonic Cs W7bkp Cs W9bkp Cs W12bkp Repair Manual

Panasonic Cs W7bkp Cs W9bkp Cs W12bkp Repair Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cs W7bkp Cs W9bkp Cs W12bkp Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							81
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							How to use electronic circuit diagram
    TIMER TABLE
    Test Mode
    NameTime(When test pointRemarks
    Short-circuited)
    Sleep ModeWaiting1 hr.6 sec.
    Sleep Mode Operation8 hrs.48 sec.
    Real Timer1 hr.1 min.
    10 min.10 sec.
    1 min.1 sec.
    Time Delay Safety Control2 min. 58 sec.0 sec.
    Forced Operation60 sec.0 sec.
    Time Save Control7 min.4.2 sec.
    Anti-Freezing4 min.0 sec.
    Auto Mode Judgement25 sec.0 sec.
    Soft DryOFF6 min.36 sec.
    ON10 min.60 sec.Soft Dry: 10 min. operation
    Deodorizing Control
    Cooling40 sec.4 sec.
    70 sec.7 sec.
    20 sec.2 sec.
    180 sec.18 sec.
    Soft Dry40 sec.4 sec.
    360 sec.36 sec.
    Comp. Reverse Rotation Detection5 min.30 sec.Comp. ON 5 min. and above
    2 min.0 sec.
    Comp./ FanMotor DelayTimer1.6 sec.0 sec.
    Powerful Mode Operation15 min.15 sec.
    Random FM Timer (Economy Mode)5 sec.5 sec.
    Random Auto Restart Control0 ~ 62 sec.0 ~ 6.2 sec.
    TRS Recovery Detection12 min.72 sec.
    6 min.36 sec.
    3 min.18 sec.
    1 min.6 sec.
    Time Save Control (Heating)30 min.3 sec.
    4 Way Valve Control (Delay)5 min.30 sec.
    Deice Operation Occurs60 min.6 sec.60 min. after previous deice
    4 min.24 sec.Continuously 4min. Comp. ON
    50 sec.0 sec.TRS ON continuouslyfor 50 sec. check
    Overload Deice Timer1 min.6 sec.Comp. ON continuouslyfor 1 min. check
    Deice End12 min.72 sec.Max. Operation time
    30 sec.3 sec.30 sec. Comp. OFF after deice
    10 sec.1 sec.4-Way Valve ON 10 sec. later after deice
    Deice Operation (Extend)60 sec.0 sec.
    120 sec.0 sec.
    180 sec.0 sec.
    Hotstart Finish30 sec.0 sec.
    82
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							20.1. REMOTE CONTROL
    83
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							20.2. PRINT PATTERN
    INDOOR UNIT PRINTED CIRCUIT BOARD
    TOP VIEW
    84
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							20.3. PRINT PATTERN
    INDOOR UNIT PRINTED CIRCUIT BOARD
    BOTTOM VIEW
    85
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5
    [MACC] Printed in Malaysia 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cs W7bkp Cs W9bkp Cs W12bkp Repair Manual