Page 1

 1 Features 2
 2 Functions 
3
 3 Product Specifications 
6
 4 Dimensions 
12
 5 Refrigeration Cycle Diagram 
14
 6 Block Diagram 
15
 7 Wiring Diagram 
16
 8 Operation Details 
17
 9 Operating Instructions 
33
 10  Installation Instructions 
38
© 2001 Matsushita Air-Conditioning Corp. Sdn. Bhd.
(183914D). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-W7BKP CU-W7BKP5
CS-W9BKP CU-W9BKP5
CS-W12BKP CU-W12BKP5
 11  2-way, 3-way Valve 49
 12  ServicingInformation 
62
 13...

Page 2

 • High Efficiency
 • Compact Design
 • Comfort Environment
 − 8 hours of sleep mode operation
 − Air filter with function to reduce dust and smoke
 − Wider range of horizontal discharge air
 • Auto Restart
 − Random auto restart after power failure for safety restart
operation
 • Removable and Washable Front Panel
 • Remote Control Self-illuminating Button
 • Catechin Air Purifying Filter
 − Trap dust, tobaccosmoke andtinyparticles
 − Prevent the growth of bacteria and viruses trapped
 • Solar...

Page 3

2 Functions
Remote Control
Operation OFF / ONOFF / ON IRoom Temperature SettingTEMP.
Operation Mode Selection
•AUTOAutomatic Operation Mode
•
HEATHeating Operation Mode
•
COOLCooling Operation Mode
•
DRYSoft Dry Operation Mode
MODE
TIMETime / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Sleep Mode Operation OFF / ONSLEEP
Indoor Fan Speed SelectionFAN SPEED
•FAN Low Fan Speed
•
FAN Medium Fan Speed
•
FAN High Fan Speed
•
AUTOAutomatic Fan SpeedFAN
Vertical Airflow...

Page 4

Indoor Unit
Random Auto Restart Control
• Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates at Low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
– Heating : Fan speed varies from Me →
SSLo in accordance with
indoor heat exchanger.
– Cooling : Fan rotates at Hi, Me and...

Page 5

Outdoor Unit
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
Overload Protector
• 2-Stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit diagram for OLP...

Page 6

3 Product Specifications
UnitCS-W7BKPCU-W7BKP5
Cooling CapacitykW (kcal/h)2.38 (2,050)
Heating CapacitykW (kcal/h)2.45 (2,110)
Moisture Removall/h (Pint/h)1.5 (3.2)
PhaseSingle
Power SourceV230
Cycle50
Airflow MethodOUTLET
INTAKE
SIDE VIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.4 (230)—
Heating; 7.0 (250)
Indoor Air (Me)m3/min (cfm)Cooling; 7.6 (270)—
Heating; 7.7 (270)
Indoor Air (Hi)m3/min (cfm)Cooling; 8.5 (300)—
Heating; 9.9 (350)
Indoor Air (SHi)m3/min (cfm)Cooling; 9.9 (350)—...

Page 7

Power Cord Length
Number of core-wirem1.9
3 (1.0 mm2)—
—
DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289)
Net Weightlb (kg)20 (9.0)71 (32)
CompressorType—Rotary (1 cylinder)
rolling piston type
MotorType—Induction (2-poles)
RatedOutputW—670
Air CirculationTypeCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%PP Resin
MotorTypeInduction (4-poles)Induction (6-poles)
InputW49.263.0
RatedOutputW1529
Fan...

Page 8

UnitCS-W9BKPCU-W9BKP5
Cooling CapacitykW (kcal/h)2.90 (2,490)
Heating CapacitykW (kcal/h)3.14 (2,700)
Moisture Removall/h (Pint/h)1.7 (3.6)
PhaseSingle
Power SourceV230
Cycle50
Airflow MethodOUTLET
INTAKE
SIDE VIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.8 (240)—
Heating; 7.0 (250)
Indoor Air (Me)m3/min (cfm)Cooling; 8.3 (290)—
Heating; 8.0 (280)
Indoor Air (Hi)m3/min (cfm)Cooling; 9.9 (350)—
Heating; 10.2 (360)
Indoor Air (SHi)m3/min (cfm)Cooling; 10.2 (360)—
Heating; 10.2 (360)
dB...

Page 9

DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289)
Net Weightlb (kg)20 (9.0)73 (33)
CompressorType—Rotary (1 cylinder)
rolling piston type
MotorType—Induction (2-poles)
RatedOutputW—780
Air CirculationTypeCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%PP Resin
MotorTypeInduction (4-poles)Induction (6-poles)
InputW49.263.0
RatedOutputW1529
Fan SpeedLowrpmCooling; 780—
Heating; 840
MediumrpmCooling;...

Page 10

UnitCS-W12BKPCU-W12BKP5
Cooling CapacitykW (kcal/h)3.74 (3,220)
Heating CapacitykW (kcal/h)4.09 (3,520)
Moisture Removall/h (Pint/h)2.2 (4.6)
PhaseSingle
Power SourceV230
Cycle50
Airflow MethodOUTLET
INTAKE
SIDE VIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 7.3 (260)—
Heating; 7.8 (270)
Indoor Air (Me)m3/min (cfm)Cooling; 9.1 (320)—
Heating; 9.1 (320)
Indoor Air (Hi)m3/min (cfm)Cooling; 10.2 (360)—
Heating; 10.6 (370)
Indoor Air (SHi)m3/min (cfm)Cooling; 10.6 (370)—
Heating; 10.6 (370)
dB...