    							DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
    Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
    Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289)
    Net Weightlb (kg)20 (9.0)77 (35)
    CompressorType—Rotary (1 cylinder)
    rolling piston type
    MotorType—Induction (2-poles)
    RatedOutputW—780
    Air CirculationTypeCross-flow FanPropeller Fan
    MaterialAS + Glass Fiber 20%PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW49.267.4
    RatedOutputW1533
    Fan SpeedLowrpmCooling; 900—
    Heating; 960
    MediumrpmCooling; 1,120—
    Heating; 1,120
    HighrpmCooling; 1,260835 - 845
    Heating; 1,300
    SuperHighrpmCooling; 1,300—
    Heating; 1,300
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinCorrugate Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×152×24
    FPI2117
    Size (W × H × L)mm610 × 315 × 25.4705.8
    735.1× 504 × 18.9
    Refrigerant Control Device—Capillary Tube
    Refrigeration Oil(cm3)—FVC68D (330)
    Refrigerant (R-410A)g (oz)—1,060 (37.4)
    ThermostatElectronic Control—
    Protection Device—Overload Protector
    Capillary TubeLengthmm—Cooling; 630, Heating; 455
    Flow Ratel/min—Cooling; 6.5, Heating; 13.6
    Inner Diametermm—Cooling; 1.2, Heating; 1.5
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    Compressor CapacitorµF, VAC—35 µF, 370VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC
     • Specifications are subjectto change without notice for further improvement.
    11
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							4 Dimensions
    12
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							13
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							5 Refrigeration Cycle Diagram
    14
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							6 Block Diagram
    15
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							REMARKS
    B: BLUE
    BR: BROWN
    BL: BLACK
    GRY: GRAY
    O: ORANGE
    P: PINK
    R: RED
    W: WHITE
    Y/G: YELLOW/GREEN
    Resistance of Indoor Fan Motor Windings
    MODELCS-W7BKP
    CS-W9BKP
    CS-W12BKP
    CONNECTIONCWA921060
    BLUE-YELLOW371.0Ω
    YELLOW-RED386.6Ω
    Note: Resistance at 20°C of ambient temperature.
    Resistance of Outdoor Fan Motor Windings
    MODELCU-W7BKP5
    CU-W9BKP5CU-W12BKP5
    CONNECTIONCWA951087CWA951086
    BLUE-YELLOW249.8Ω195.9Ω
    YELLOW-RED288.6Ω206.6Ω
    Note: Resistance at 20°C of ambient temperature.
    Resistance of Compressor Windings
    MODELCU-W7BKP5
    CONNECTIONGB080PAA
    C-R4.96Ω
    C-S4.67Ω
    Note: Resistance at 25°C of ambient temperature.
    MODELCU-W9BKP5
    CONNECTIONGB102PAA
    C-R3.77Ω
    C-S4.02Ω
    Note: Resistance at 25°C of ambient temperature.
    MODELCU-W12BKP5
    CONNECTIONGB134PAA
    C-R(Main)3.27Ω
    C-S(Sub)3.02Ω
    Note: Resistance at 25°C of ambient temperature.
    7 Wiring Diagram
    16
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							Cooling in operation according to Remote Control setting.
    Time Delay Safety Control (3 minutes)
    7 minutes Time Save Control
    Starting Current Control
    Anti-Freezing Control
     • If the temperature of the indoor heat exchanger falls
    continuously below 2°C for 4 minutes or more, the
    compressor turns off to protect the indoor heat exchanger
    from freezing. The fan speed setting remains the same.
     • Compressor will restart again when the indoor heat
    exchanger temperature rises to 10°C (Recovery).
    3 minutes waiting ofTime Delay Safety Control is valid for
    Cooling Operation.
    Compressor Reverse Rotation Protection Control
    8 Operation Details
    8.1. Cooling Mode Operation
     • When the compressor is stopped by Remote Control, it restarts after 3 minutes when it is turned ON by Remote Control.
     • When the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes.
     • The compressor will startautomatically if it has stopped for 7 minutes evenif the room temperature is between the compressor
    ON temperature and OFF temperature.
     • When the compressor outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will operate 1.6
    second later.
     • If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and
    indoor heat exchanger is 2.5°C or less for2 minutes, compressor willstop and restart automatically.
    (Time DelaySafety Controlis valid)
    sT = Intake air temperature - Indoor heat exchanger temperature
    This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
    17
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							Compressor Protection Control
    Anti-Dew Formation Control
    Automatic Fan Speed Mode
     • After the compressor starts for 50 seconds but the outdoorfan motor is still OFF, the compressor will stop and restart
    automatically. (Time Delay SafetyControl is valid).
     • If the above phenomenon is repeated for3 times, the compressorwill stop totally.
     • The above phenomenon is reset when there is achange to heating mode or stopped by Remote Control Switch.
     • Purpose is to prevent dew formation on indoor unit air discharge area.
     • When the following conditions occur for 30 minutes continuously, anti-dew formation is controlled by indoor fan speed shift to
    low (CLo to HLo):
     − Indoor intake air temperature is more than 24°C and less than 30°C.
     − Remote Control setting temperature is less than 25°C.
     − Compressor is on.
     − Cooling operation mode.
     − Indoor Fan motor operate at Low fan speed.
     • This control iscancelled immediately when abovecondition is changed.
    When Automatic Fan Speed is selected at Remote Control during cooling operation.
     • Fan speed rotates in the range of Hi to Me.
     • Deodorizing Control.
    18
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							Cooling Operation Time Diagram
    19
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						
    							Time Delay Safety Control
    Starting Current Control
    Anti-Freezing Control
    Compressor Reverse Rotation Protection Control
    Compressor Protection Control
    Anti-Dew Formation Control
    Automatic Fan Speed Mode
    8.2. Soft Dry Mode Operation
     • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
    then Soft Dry operation will start.
     • During Soft Dry operation, the Indoor Fan will operate at SLo speed.
     • The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
    off, it stops for 6 minutes.
     • Once the compressor stops, it will not start for 3 minutes during Cooling operation.
     • Same as Starting Current Control for Cooling Mode operation.
     • Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
    stops.)
     • Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
    is valid during compressor stops.)
     • Same as Compressor Protection Control for Cooling Mode Operation.
     • Same as Anti-Dew Formation Control for Cooling Mode Operation.
    When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
     • Fan speed rotates at SLo speed.
     • Deodorizing Control.
    20
    CS-W7BKP CU-W7BKP5 / CS-W9BKP CU-W9BKP5 / CS-W12BKP CU-W12BKP5 
    						