Page 31
5-4. Heating Capacity Indoor Unit : CS-KE12NB41 & CZ-18BT1U Outdoor Unit : CU-KE12NK1 Power Supply : 115V Single Phase 60Hz < Heating Capacity > TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold...
Page 32
Indoor Unit : CS-KE18NB4UW & CZ-18BT1U Outdoor Unit : CU-KE18NKU Power Supply : 230V Single Phase 60Hz < Heating Capacity > TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention...
Page 33
6. ELECTRICAL DATA 6-1. Electrical Characteristics Indoor Unit CS-KE12NB41 & CZ-18BT1U Outdoor Unit CU-KE12NK1 Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor + Compressor Performance at 115V Single-phase 60Hz Rating conditions Running amp. A 0.21 Power input W 1812.39 1,242 Heating Cooling 12.6 1,260 Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor + Compressor Performance at 115V Single-phase 60Hz Rating conditions Running amp. A 0.25 Power input W 2014.35 1,44014.6...
Page 34
Indoor Unit CZ-KE18NB4U & CZ-18BT1U Outdoor Unit CU-KE18NKU Indoor Unit Outdoor Unit Fan Motor Fan Motor + Compressor Performance at 230V Single-phase 60Hz Rating conditions Running amp. A 0.15 Power input W A W A W A W228.15 1,838 Rating conditions: Indoor air temperature: 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB Outdoor air temperature: 95 °F (35 °C) DB Rating conditions: Indoor air temperature 70 °F (21.1 °C) DB Outdoor air temperature 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB Heating...
Page 35
6-2. Electric Wiring Diagrams Indoor Unit CS-KE12NB41 & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U 8FA2-5250-46900-2 123456 123456 FMDP FAN MOTORDRAIN PUMP DCM 6P (BLU) 6P (WHT)DP 3P (BLU) 3P (RED)PWM/POW 7P (RED) PWM/POW 7P (RED) RC 4P (WHT)IND 7P (WHT)FS 3P (RED) FLAP 5P (WHT)ROOM 2P (YEL)COIL-1 2P (RED) IND LAMP ASSYFLAP (W) FLOAT SWITCH BOX BOX SERIAL 2P (WHT)SERIAL 2P (WHT) TERMINAL BASE CONTROLLER CONTROLLER TO OUTDOOR UNIT GNDFERRITE COREAC1 AC2 SI1 RED YELBLU 11YEL/(RED)33 112 1122 1122 23344556677...
Page 37
8FA2-5251-11900-2 Outdoor Unit CU-KE18NKU 25A CONTROLLER DCFM MV0RV 0 RV1 FAN MOTOR 1 234567 BLKWHTREDBLUYEL BLKWHTREDBLUYEL BLKBLK REDRED w w w w w w ww ww12345512431212 12345671245673 12 1234 3455 1 122 12 1233 12 12 1234124312341243 21 2 1 FERRITE CORE COMPRESSOR THERMISTOR OUT DOOR THERMISTOR COIL THERMISTOR MV0 MAGNETIC COIL w w *ELEC SYSTEM ASSY 1 2 3 4 5 6 REACTANCE WHT2P-CONNECTOR (WHT) 2P-CONNECTOR (WHT) WHTWHT WHT REDRED(PINK) RED(PINK) WHT WHT WHT WHTWHT WHT BLU BLU U V W...
Page 38
ACL (Reset) button 1HR. TIMER button ON/OFF operation button HIGH POWER button Test run mode Self-diagnostic mode Address setting mode Fig. 1 Fig. 2 Fig. 3 Ta b ACL button 7. MAINTENANCE 7-1. Address Setting of the Remote Controller The address can be set in order to prevent interference between remote controllers when two indoor units are installed near each other. The address is normally set to "A." To set a different address, it is necessary to change the address on the second remote...
Page 39
One of the two types of connectors illustrated at left is used. Their basic structure is the same for each. How to Disconnect Hold the resin connector cover, and pull the connector off. You cannot disconnect the connector by pulling the wire since it is locked inside. Always hold the cover to disconnect. (See illustration at left.) For the connector without the resin cover, push the lock in the direction of "2" while pulling it off. How to Connect In order to connect, hold the resin cover of...
Page 40
7-3. Disassembly Procedure 7-3-1. Remove the air intake grill. (1) Slide the 2 latches each to the corresponding arrow direction. (Fig. 1 and Fig. 2) Open downward the air intake grill located on the latch side. (2) Undo the air intake grill drop preventive hook. (Fig. 3) Undo the 2 hinges for the grill and remove the air intake grill. 7-3-2. Disconnect the connectors in the control box. (1) Remove the 2 screws and remove the control box cover. (Fig. 4) (2) Disconnect the connectors CN04 (FLAP...