$Connection with multiple cameras (Color lock mode)An example of connection for VBS/BB input (Color lock
mode).
• One of the multiple cameras is used as the source of
reference signals.
• Supply a synchronizing signal (BB) to the G/L input
connectors of each cameras.• Do not switch off the camera used for supplying the
reference signals.
• Adjust the SC-phase and H-phase at the Video Output
connector.
VIDEO OUT CAMERA
Camera for external sync 
(or special effect generator)G/L IN
VIDEO OUT
OUTPUT...

Page 22

-22-
DC Power supply
Cable AW-CA4T1
Computer VIDEO OUT connector
AC adapter AW-PS50575 Ωcoaxial cable
Composite video
input connector
(VIDEO IN)Video monitor
RS-232C PC control cable AW-CA50T9 (10m)
$Connection of computerThe system shown here can remotely control this camera by using a computer.
The software and the cable for RS-232C required for this operation should be obtained locally.
Please contact qualified service personnel for this software.$Connection of devices with camera pan/tilt control...

Page 23

-23-
Adjustment$Automatic white balance control (AWC)There are two white balance memories, “AWC A” or “AWC
B” for two different light sources color temperatures, with the
automatic white balance setting. Then, when the two
different light sources are encountered, you may operate the
camera properly by simply change the white balance mode
to either AWC A or AWC B. There is no need to readjust the
camera to the ambient conditions.
❈The preset conditions will be renewed whenever you input
new conditions.
1....

Page 24

-24-
Notes:
• For white balance setting aim the camera at a white object
and try to position it in the center of the monitor screen.
The object must appear in over 10 % of the total monitor
screen area. Try to avoid overly bright objects in the scene.
• White balance may not be correctly set if the lighting of the
object is too weak.
• Since the camera has a built-in memory, the set white
balance will remain in the memory even if power is turned
off. Therefore, it is not necessary to reset the white...

Page 25

-25-
$Reset to 3200K or 5600K white balanceWhen the white balance setting is set to either “3200K” or
“5600K” the white balance will be automatically set to the
color temperature 3200K or 5600K, respectively.$Black balance adjustment• Close the lens.
If the motor drive lens is controlled from the camera, the
lens is automatically closed when the black balance is
adjusted.
• When the camera is used without a RCU or RCB, R/B
pedestal adjustment of painting setting will be
automatically reset to ±0 after...

Page 26

-26-
Adjustment$Total pedestal level adjustment(Use an oscilloscope or a waveform monitor for this
adjustment.)
This step is to adjust the black levels (pedestal levels) of two
or more cameras to be the same.
[ADJUSTMENT by CAMERA]
1. Close the lens.
2. Select Pedestal item in the brightness setting Sub Menu.
(Select [Pedestal] in the [Iris, Shutter, Gain Set] sub
menu in User Mode.)
3. Set the pedestal level to 5 IRE (0.035 V) with the
YES/ABC switch or the NO/BAR switch.
[ADJUSTMENT with RCU (RCB,...

Page 27

-27-
$Gen-lock adjustmentPhase adjustments must be performed with the camera or
the RCU (RCB) when external synchronizing signals are
supplied to the system in cases where multiple cameras are
used or peripheral devices are connected.
UHorizontal phase control
Observe the waveform of the external synchronizing input
signal (black burst signal) and video output signal on a 
two-channel oscilloscope. Then match the horizontal phase
of both signals by adjusting them with the cameras or RCU’s
horizontal...

Page 28

-28-
Caution:
• When horizontal phase adjustment is required using RCU
(RCB) or hybrid control panel, BAR/CAM switch should be
set to BAR. Horizontal phase cannot be adjusted if the
switch is in the CAM position. After adjustment set
BAR/CAM switch back to CAM.
• When horizontal phase adjustment is moved, color phase
is also moved. Adjust color phase whenever horizontal
phase adjustment is moved.
UColor phase adjustment
Supply the output signal (split color bar) from the color
special effect generator to...

Page 29

-29-
Use mode setting$Use Mode SettingThe camera has four use modes, and various functions for
four use modes have been preset.
Functions can be set as best suited to each use mode.
• Halogen mode
Suited to indoor shooting, such as at weddings, parties,
lecture meetings, events, etc.
Settings can be changed using a simple menu.
• Fluorescent mode
Suited to indoor shooting under fluorescent lighting.
Settings can be changed using a simple menu.
• Outdoor mode
Suited to outdoor shooting.
Settings can be...

Page 30

-30-
Scene File Switch  Scene File Switch 
Operation mode Position of  Position of Hybrid 
RCU (RCB) control panel
Halogen Mode 1 1Fluorescent Mode 2 2Outdoor Mode 3 3
User’s Mode USER SET 4$Setting by RCU (RCB) or hybrid control
panelAn operation mode is selected depending on the position of
the scene file switch.
CAMERA RCU (RCB) Hybrid control panel
MENU
ITEM/AWC
YES/ABC
NO/BAR
SCENE
FILE switchSCENE FILE switchUse mode setting 