Page 41
-39- #0Auto Iris Level Fine Adjustment [Auto Iris Adjust: ON/OFF] ON:Fine adjustment of auto iris convergence level can be made with the iris control when the iris switch on the RCU (RCB) or on the hybrid control panel is in the AUTO posi- tion. OFF:The iris control is invalid when the iris switch on the RCU (RCB) or on the hybrid control panel is in the AUTO position. All Center Top cut BTM cut R/L cut RB RB PED TOTAL PEDA BATW AWC AUTOHOLD ABC IRISMAN AUTO1000 S/S...
Page 42
-40- #1Electronic Shutter Mode Setting [Shutter Mode: Step/ ELC/ S/Scan] Step:Electronic shutter operates at the speed selected by the Electronic Shutter Step Setting #2. ELC:Electronic shutter is controlled to automatical- ly adjust the luminance. S/Scan (Synchro Scan):Electronic shutter oper- ates at the speed selected in Electronic Shutter Synchro-Scan Setting #3. • In case of using the RCU (RCB), none of the shutter speeds–1/250, 1/2 000, 1/4 000, and 1/10 000...
Page 43
Synchro-scan - 99.68 Hz 250.0 Hz 492.2 Hz 984.4 Hz 1.969 kHz 3.938 kHz 7.875 kHz Shutter Speed OFF 1/100 1/250 1/500 1/1 000 1/2 000 1/4 000 1/10 000 Required luminance ratio 1 2 4 8 16 32 64 160 -41- #4CCD Read Out Mode Setting [Field/Frame: Field/Frame 1/Frame 2] Field:CCD storage will be by field storage. Frame 1:Vertical resolution increases in frame stor- age. Frame 2:Vertical resolution is raised without increasing residual images by frame storage and electronic shutter. #5Gain Up Setting...
Page 44
-42- #6Black Level Setting [Pedestal: –30 - +30] The black level (pedestal) of the luminance (Y) sig- nal can be set. Used in adjusting the black levels of two or more cameras. #7Chroma Level Adjustment [Chroma Level: –3 - +3] Chroma Level can be decreased or increased to three levels. #8White Balance Setting [White Bal: ATW/AWC A/ AWC B/P SET 3 200K/P SET 5 600K] ATW:The white balance is automatically adjusted to the optimum position. AWC A, AWC B:Color temperature...
Page 45
-43- RB RB PED TOTAL PEDA BATW AWC AUTOHOLD ABC IRISMAN AUTO1000 S/S ELC 500 100 OFFSHUTTER SCENE21 3 USER SET AUTO/ATWPAINTINGGAIN R/B Gain Control RCU (RCB) R/B Pedestal Control $12-dimensional Lowpass Filter Setting [2D LPF: OFF/ LOW/ HIGH] The 2D lowpass filter that reduces moire and cross color can be set. $2Horizontal Phase Adjustment [H Phase: –206 - +49] Horizontal phase can be adjusted when a genlock signal is supplied. $3Subcarrier Phase Coarse Adjustment [SC Coarse: 1/2/3/4]...
Page 46
-44- %3Skin Color Detail Level Setting [DTL Flesh Tone: LOW/MID/HIGH] LOW:Skin color coarseness is suppressed. MID:Standard HIGH:Skin color is emphasized. %4Corner Detail Setting [Corner Detail: OFF/ON] Corner detail, which improves the resolution of cor- ners, can be turned on or off when the Detail Level Setting $6is at HIGH or LOW. %5Precision Detail Level Setting [Precision Detail: OFF/LOW/HIGH] This setting is to narrow detail width and suppress detail glare. $9Noise...
Page 47
-45- %6Color Matrix Compensation Level Setting [Matrix (R-G)/(R-B)/(G-R)/(G-B)/(B-R)/(B-G): –31 - +31] Color Matrix compensation level can be adjusted. (R-G):To increase or decrease the intermediate color between red and magenta (R-B):To increase or decrease the intermediate color between red and yellow (G-R):To increase or decrease the intermediate color between green and cyan (G-B):To increase or decrease yellowish green (B-R):To increase or decrease the intermediate color between...
Page 48
-46- Setting to initial set In case of the wrong setting in any use mode, take the following steps to return to the initial settings. (1) Select [Initialize Data] on the main menu screen of each Use Mode. (See page 29.) Press the YES/ABC switch, then [Initialize Data] screen shown for about 10 seconds. (2) Press the YES/ABC switch within about 10 seconds to return to the initial settings, the existing settings ** Initialize Data ** (Halogen Mode) Do you want to...
Page 49
Item ±0 0 Top cut ON HIGH ---–10 MID G/L. Color Bar Set±0 1 ±0 7.5 IRE -47- INITIAL SETTINGS OF THE SETTING ITEMS (Factory preset values) Halogen, Fluorescent, Outdoor Mode Picture Level Light PEAK/AVG Light Area Auto ND (ELC) Auto Gain Up Manu Gain Up Pedestal Contrast (Gamma) Brightness Set Other SetShutter Speed Synchro Scan V Resolution Baud Rate Nega/Posi+2 ±0 ATW OFF Sharpness HIGH OFF OFF MID Auto ND ---Normal 9600bps PosiOutdoor mode +1 ±0 AWC A OFF ±0 1 ±0 7.5 IRE Sharpness HIGH OFF OFF MID...
Page 50
-48- User Mode Iris, Shutter, Gain Set 0.45 88% 110% 0 0 0 OFF OFF 9 600bps Posi HIGH +11 +12 +7 +6 2 3 0% 0 Picture Level Light PEAK/AVG Light Area Auto Iris Adjust Shutter Mode Step Synchro Scan Field/Frame Gain Pedestal±0 0 Top cut OFF Step OFF --- Field 0dB ±0 Chroma Level White Bal High-light Chroma Painting R Gain B Gain R Pedestal B Pedestal 2D LPF Color Set±0 AWC A OFF ±0 ±0 ±0 ±0 OFF H Phase SC Coarse SC Fine Color Bar Set G/L. Color Bar Set±0 1 ±0 7.5 IRE Detail H Detail Level H V Detail Level...