-19- CONNECTION OF COMPUTER The system shown here can remotely control this camera by using a computer. The software and the cable for RS-232C required for this operation should be obtained locally. Please contact qualified service personnel for this software. – + MENU ITEM/AWC YES/ABC NO/BAROPTION CARD VIDEO OUT I/F REMOTE G/L IN IRIS DC12V IN ONPOWEROFFPOWERO I FUSE(POWER)FUSEFUSEAC Adaptor AW-PS505 DC Power Cable AW-CA4T1 Computer VIDEO OUT Connector AC ADAPTOR AW-PS50575 ΩCoaxial Cable...
Page 22
-20- Color temperature and adjustment of white balance When carbon is burnt, it develops various colors of light depending on the temperature. Natural light can be specified by color temperature referring to the color developed when carbon is burnt. The light of 3 200K (K=Kelvin, −273C equals to abso- lute zero temperature 0K) represents the same value (color) as what develops when carbon is burnt at 3 200K (2 927C). The relationship between the color...
Page 23
-21- AUTOMATIC WHITE BALANCE CONTROL (AWC) There are two white balance memories, “AWC A” or “AWC B” for two different light sources color tempera- tures, with the automatic white balance setting. Then, when the two different light sources are encountered, you may operate the camera properly by simply change the white balance mode to either AWC A or AWC B. There is no need to readjust the camera to the ambient conditions. * The preset conditions will...
Page 24
-22- Notes: • For white balance setting aim the camera at a white object and try to position it in the center of the monitor screen. The object must appear in over 10 % of the total monitor screen area. Try to avoid overly bright objects in the scene. • White balance may not be correctly set if the lighting of the object is too weak. • Since the camera has a built-in memory, the set white balance will remain in the memory even if power is turned off....
Page 25
-23- RESET TO 3 200K OR 5 600K WHITE BALANCE When the white balance setting is set to either “P SET 3 200K” or “P SET 5 600K” the white balance will be automatically set to the color temperature 3 200K or 5 600K, respectively. BLACK BALANCE ADJUSTMENT • Close the lens. If the motor drive lens is controlled from the cam- era, the lens is automatically closed when the black balance is adjusted. • When the camera is used without a RCU or RCB, R/B pedestal...
Page 26
-24- TOTAL PEDESTAL LEVEL ADJUST- MENT (Use an oscilloscope or a waveform monitor for this adjustment.) This step is to adjust the black levels (pedestal levels) of two or more cameras to be the same. [ADJUSTMENT by CAMERA] 1. Close the lens. 2. Select Pedestal item in the brightness setting Sub Menu (Select [Pedestal] in the [Iris, Shutter, Gain Set] sub menu in USER MODE.) 3. Set the pedestal level to 5 IRE (0.035 V) with the YES/ABC switch or the NO/BAR...
Page 27
-25- [ADJUSTMENT by CAMERA] 1. Press the NO/BAR switch for over 5 seconds to dis- play the color bar. 2. Select [G/L. Color Bar Set] on the main menu, then select [H PHASE] on the submenu. 3. Adjust the horizontal phase with the YES/ABC and NO/BAR switch. External gen-lock input signal (black burst output of special effect generator) Video signal [ADJUSTMENT with RCU (RCB, Hybrid control panel )] Use the horizontal phase control. **G/L.yColor Bar Set** H Phase ±0 SC...
Page 28
-26- COLOR PHASE ADJUSTMENT Supply the output signal (split color bar) from the color special effect generator to a color monitor or vec- torscope. Adjust the color phase of the camera. [ADJUSTMENT with RCU (RCB, Hybrid control panel)] Use the subcarrier phase coarse adjustment control and subcarrier phase fine control. * It is recommended that a vectorscope be used for maximum accuracy in color phase adjustment. [ADJUSTMENT by CAMERA] 1. Press the NO/BAR switch for over...
Page 29
-27- Use Mode Setting The camera has four use modes, and various functions for four use modes have been preset. Functions can be set as best suited to each use mode. • Halogen mode Suited to indoor shooting, such as at weddings, parties, lecture meetings, events, etc. Settings can be changed using a simple menu. • Fluorescent mode Suited to indoor shooting under fluorescent lighting. Settings can be changed using a simple menu. • Outdoor mode Suited to outdoor shooting. Settings can be...
Page 30
POWEROPERATE BAR CAMMODEGAIN AWC SCENE FILEABC AT W A B AUTO/AIW ELC LOW MID MANUON SCH OFF HIGH AGC OFF 1 / 100SHUTTERON OFF 1 . 2 . 3 . 4 . G/L PHASE T.PEDCABLE COMP 90° 180° 0° 270° YC SCENE FILE Switch Operation mode -28- SETTING BY RCU (RCB) OR HYBRID CONTROL PANEL An operation mode is selected depending on the posi- tion of the scene file switch. Halogen Mode Fluorescent Mode Outdoor Mode User's Mode Scene File Switch Position of RCU (RCB) 1 2 3 USER SETScene File Switch...