Home > Panasonic > Camera > Panasonic Convertible Camera Aw E300a Operating Instructions

Panasonic Convertible Camera Aw E300a Operating Instructions

Here you can view all the pages of manual Panasonic Convertible Camera Aw E300a Operating Instructions. The Panasonic manuals for Camera are available online for free. You can easily download all the documents as PDF.

Page 11

-9-
13. Cable Clamp
Clamp  the  DC  Power  Supply  Cable  (AW-CA4T1)
connected  to  the  DC  12  V  Input  Connector  to  pre-
vent it from slipping out.
14. G/L Input Connector (G/L IN)
Signals  synchronized  with  the  reference  signal  are
to be supplied to this connector when the camera is
to be synchronized with the reference signal BB.
15. Optional Card Slot
Slot for inserting an optional card.  For details, refer
to the manual for optional cards. 12. DC 12 V Input Connector (DC 12V IN)
12 V DC is...

Page 12

-10-
• 1/3”  C  mount  type  lens  can  be  mounted  on  the
camera.
• There  may  be  a  danger  of  damage  to  the  camera
depending  on  the  type  of  lens.    Use  a  lens  whose
mount screw height is 4.3 mm or less.
– +
MENU
ITEM/AWC
YES/ABC
NO/BAROPTION  CARD
VIDEO  OUT
I/F  REMOTE
G/L IN
IRIS
DC12V IN
Control Cable
To Lens I/F Connector of
Camera Pan/tilt Unit
Camera Cable
To Iris Connector
1. Lens Mounting
Remove  the  body  cap  from  the  camera  by  pulling
on it.
Attach the lens into the...

Page 13

-11-
2. Fix  the  camera  mounting  base,  pan/tilt  unit,  and  tri-
pod  securely  in  the  screw  hole  (1/4-20UNC)  of  the
camera mounting adaptor.
3. If  the  camera  cannot  be  securely  fixed,  stick  the
supplied  rubber  sheet  to  the  mounting  adaptor,
then mount the camera.
Mounting adaptor
2. Camera Mounting
1. Fix the mounting adaptor to the top or bottom of the
camera.
Camera Mounting Bracket (WV-831)
When  changing  the  camera  mounting  adapter,  use  a
screwdriver or similar tool to...

Page 14

-12-
1. Fully  open  the  iris  by  shooting  a  dark  object.    (Iris
selection switch should be set to M.)
2. Remove  the  cap  from  the  camera’s  Flange-back
Adjustment Screws.
3. Loosen the flange back lock screw.
4. Aim  the  camera  at  any  object  over  2  meters  away
from the camera.
5. Set the lens to its TELE end first and adjust its focus
with the focus ring.
6. Set  the  lens  to  its  widest  angle  next  and  adjust  its
focus with the focus screw.
7. Adjust the focus ring and the...

Page 15

-13-
IRIS GAIN CONTROL IN A LENS
An  iris  gain  control  hole  is  usually  provided  in  the  front
of the lens. Adjustment of the iris gain, with a screwdriv-
er  through  the  hole  may  be  done  as  follows.    (Shape
and  location  of  the  hole  may  vary  depending  on  the
type of lens.)
1. Turn the iris selection switch to Position A (AUTO).
2. Rotate  the  iris  gain  control  to  the  maximum  gain,
but in a range where no hunting or oscillating of the
iris ring develops.Iris gain control...

Page 16

-14-
Caution:
The connection and installation should be done by qualified service personnel or system installers.
Refer any servicing to qualified service personnel.
CONNECTIONS
– +
MENU
ITEM/AWC
YES/ABC
NO/BAROPTION  CARD
VIDEO  OUT
I/F  REMOTE
G/L IN
IRIS
DC12V IN
ONPOWEROFFPOWERO    I
FUSE(POWER)FUSEFUSEAC Adaptor  AW-PS505
CONNECTION OF DEVICE WITH A COMPOSITE INPUT CONNECTOR
1. Connect this to a DC 12 V class 2 power supply only.
2. To  prevent  fire  or  shock,  the  UL  listed  wire  VW-1,  style...

Page 17

-15-
– +
MENU
ITEM/AWC
YES/ABC
NO/BAROPTION  CARD
VIDEO  OUT
I/F  REMOTE
G/L IN
IRIS
DC12V INGEN-LOCK GEN-LOCK
INAUX AUX
INAUTO AUTO
75 75
/Hi-Z
/Hi-ZAUTO
AUTO
75 75
/Hi-Z
/Hi-ZR/PR /C
R/PR /C
OUT
OUTOUT
OUT
AUDIO AUDIOSEE MANUAL
VIDEO 1
VIDEO 1
G/Y/Y G/Y/YVIDEO 2
VIDEO 2
B/PB /B B/PB /BSYNC
SYNCS-VIDEO
S-VIDEO14
23TALLY
TALLY
CAMERA (MULTI)
CAMERA (MULTI)
CABLE SELECT CABLE SELECTFUSE
FUSE250V  1.25A
250V  1.25A
TALK
TALK
INCOM INCOM
RECEIVE RECEIVECONTROL
TALLY & INCOM
TALLY & INCOM
MULTIOVP
OVP
MPX...

Page 18

-16-
– +
MENU
ITEM/AWC
YES/ABC
NO/BAROPTION  CARD
VIDEO  OUT
I/F  REMOTE
G/L IN
IRIS
DC12V IN
ALL 1
2USER  SETONPOWEROFFPOWERO    I
FUSE(POWER)FUSEFUSEAC Adaptor  AW-PS505
CONNECTION OF A REMOTE CONTROL BOX (RCB)
The  RCB  (WV-CB700A)  and  the  camera  must  be  con-
nected with the optional RCB cable AW-CA50T10.
1. Turn RCB power off before connecting cables.
2. Connect  the  50-pin  connector  of  the  RCB  cable  to
I/F  REMOTE  connector  of  the  camera.    The  10-pin
connector must be connected...

Page 19

-17-
• To  connect  the  pan/tilt  unit  to  the  camera,  use  the
pan/tilt unit cable AW-CA50T15.
• Power is supplied from the pan/tilt unit.
1.Before  connecting  them,  press  the  power
switch  on  the  pan/tilt  unit  AC  adaptor  and  the
ON/OFF  switch  on  the  hybrid  control  panel  in
the OFF position, respectively.
2.Fix the camera securely to the pan/tilt unit using
the mounting adaptor.
3.Connect the 50-pin end of the pan/tilt unit cable
to the I/F Remote connector on the camera.
Connect...

Page 20

-18-
CONNECTION WITH MULTIPLE CAMERAS (COLOR LOCK MODE)
An  example  of  connection  for  VBS/BB  input  (Color  lock
mode).
• One of the multiple cameras is used as the source of ref-
erence signals.
• Supply  a  synchronizing  signal  (BB)  to  the  G/L  Input
Connectors of each cameras.• Do not switch off the camera used for supplying the
reference signals.
• Adjust  the  SC-phase  and  H-phase  at  the  Video
Output Connector.
Convertible  Camera AW –FOCUS
LOCK
Convertible  Camera AW –FOCUS
LOCK...
Start reading Panasonic Convertible Camera Aw E300a Operating Instructions

Related Manuals for Panasonic Convertible Camera Aw E300a Operating Instructions

All Panasonic manuals