-41- NORMAL:Sets the horizontal resolution to more than 480 lines. HIGH:Sets the horizontal resolution to more than 510 lines. Note:After selecting HIGH, noise may increase when the SENS UP function is activated under low illumination. • Digital Noise Reduction (DNR) DNR may be used to improve quality under low light conditions. There are 4 levels of DNR, which may be selected depending on local site conditions. Factory default setting: LOW2 You may need to try different settings to find the most...
Page 42
-42- •PIX OFF Setting (PIX OFF) In this setting, you can assign a blemish position and compensate the blemish. 1. Move the cursor to PIX OFF and press the CAM (SET) key. The PIX OFF menu appears. 2. Select a number and press the CAM (SET) key. The blemish compensation position setting screen appears. Move the joystick to place the + cursor on the blemish position. After moving the + cursor to a position where the blemish looks inconspicuous, press the CAM (SET) key. Consequently, the blem- ish...
Page 43
-43- Reset to the Factory Default Settings Any of the above settings plus the ALC/MANUAL level control and phase adjustments can be reset to the fac- tory default settings by placing the cursor over the desired mode and then pressing the F2 button of WV- CU550C/CJ. For WV-RM70, hold down the right and left switches simultaneously for 2 seconds or more. For WV-CU360C/CJ and WV-CU161C, hold down the [4] and [6] keys simultaneously for 2 seconds or more. ■RS485 Setup ●Initial Camera Communication...
Page 44
-44- Menu TOP MENU SPECIAL 1 CAMERA MENU SPECIAL 2HOME POSITION SELF RETURN AUTO MODE AUTO PAN KEY DIGITAL FLIP PASSWORD LOCK PRIVACY ZONE PROPO.P/T AREA TITLE PATROL CLEANING EL-ZOOM PRESET ALM IMAGE HOLD TILT ANGLE CAMERA ID ALC/MANUAL SUPER-D2 SHUTTER AGC SENS UP SYNC WHITE BAL MOTION DET AF MODE CHROMA GAIN AP GAIN PEDESTAL RESOLUTION DNR BW PIX SENS UP BURST (BW)OFF OFF OFF AUTO PAN ON OFF OFF ON OFF STOP OFF ON OFF OFF 0° OFF ALC OFF AUTO ON (MID) OFF INT ATW1 OFF AUTO L ••••I•••• •••• I••••...
Page 45
INSTALLATION ■Mounting the Camera Ceiling mount The figure shows an example of the camera mounted on a ceiling with a locally procured bracket. Refer to the instructions included with the bracket for filling gaps and holes with waterproof material. Sun Shield Use the optional WV-7176E Sun Shield to protect the camera from direct sunlight. See instructions included with the sun shield. -45- Precautions •The following steps of installation and connection work should be done by qualified service personnel...
Page 46
-46- 1. Preparations (1) Procure a ceiling mount bracket. (2) Installation Surface CAUTION:Consult an expert on the load bear- ing capacity of the installation surface and structure. If the surface is not strong enough, the camera may fall down. Refer to the prod- uct specifications for weights. Prepare appropriate hardware (e.g. wall nuts, anchor bolts, etc.) for fixing on the installation surface. 2. Disassembling the Camera (1) Remove the upper base from the camera by loosening 3 screws. Turn the...
Page 47
-47- 4. Setting the Switches The 8-bit DIP switch has two functions. It is used to restore the factory default settings and to specify the unit number. Before setting, peel off the seal cover- ing the switch holes. After setting the switch, replace the seal. The 4-bit DIP switch selects termination ON/OFF and half/full duplex for RS485 communica- tion. The switch settings are read into the camera when the power is turned on. After changing the switch settings, be sure to turn the power off, then...
Page 48
-48- Unit Number Switch 1, an 8-bit DIP switch, specifies the unit number or restores the factory default settings when using the Panasonic protocol. When the switch position corresponding to the unit number 1-96* is selected, setting should be made on the RS485 SET UP menu (see page 43). For Panasonic’s Protocol 1234 ON5678 Switch positionUnit number 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234...
Page 49
-49- 1234 ON5678 Switch positionUnit number 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 Switch positionUnit numberSwitch positionUnit number 69 70 71 72 73 74 75 76 7778 79 80 81 82 83 84 85 8687 88 89 90 91 92 93 94 951234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678
Page 50
-50- Notes: •Defaults are marked with *. •BP stands for Bit Position. •Full duplex is not available in a daisy chain connec- tion. (Panasonic system controllers only) 5. Mounting the camera (1) Aim the START arrow at the bent portion of the leaf spring.(2) Be sure to hook the fall prevention wire into the bracket. (3) Fix the camera to the upper base. •Move the camera up so that its guide pins fit into the guide holes of the upper base. •Turn the camera counter-clockwise to the end, viewed from the...