Page 41

-41-
NORMAL:Sets the horizontal resolution to more
than 480 lines.
HIGH:Sets the horizontal resolution to more than
510 lines.
Note:After selecting HIGH, noise may increase
when the SENS UP function is activated under
low illumination.
• Digital Noise Reduction (DNR)
DNR may be used to improve quality under low light
conditions. There are 4 levels of DNR, which may be
selected depending on local site conditions. Factory
default setting: LOW2
You may need to try different settings to find the most...

Page 42

-42-
•PIX OFF Setting (PIX OFF)
In this setting, you can assign a blemish position
and compensate the blemish.
1. Move the cursor to PIX OFF and press the CAM
(SET) key. The PIX OFF menu appears.
2. Select a number and press the CAM (SET) key. The
blemish compensation position setting screen
appears.
Move the joystick to place the + cursor on the
blemish position. After moving the + cursor to a
position where the blemish looks inconspicuous,
press the CAM (SET) key. Consequently, the blem-
ish...

Page 43

-43-
Reset to the Factory Default Settings
Any of the above settings plus the ALC/MANUAL level
control and phase adjustments can be reset to the fac-
tory default settings by placing the cursor over the
desired mode and then pressing the F2 button of WV-
CU550C/CJ.
For WV-RM70, hold down the right and left switches
simultaneously for 2 seconds or more.
For WV-CU360C/CJ and WV-CU161C, hold down the
[4] and [6] keys simultaneously for 2 seconds or more.
■RS485 Setup
●Initial Camera Communication...

Page 44

-44-
Menu
TOP MENU
SPECIAL 1
CAMERA MENU
SPECIAL 2HOME POSITION
SELF RETURN
AUTO MODE
AUTO PAN KEY
DIGITAL FLIP
PASSWORD LOCK
PRIVACY ZONE
PROPO.P/T
AREA TITLE
PATROL
CLEANING
EL-ZOOM
PRESET ALM
IMAGE HOLD
TILT ANGLE
CAMERA ID
ALC/MANUAL
SUPER-D2
SHUTTER
AGC
SENS UP
SYNC
WHITE BAL
MOTION DET
AF MODE
CHROMA GAIN
AP GAIN
PEDESTAL
RESOLUTION
DNR
BW
PIX SENS UP
BURST (BW)OFF
OFF
OFF
AUTO PAN
ON
OFF
OFF
ON
OFF
STOP
OFF
ON
OFF
OFF
0°
OFF
ALC
OFF
AUTO
ON (MID)
OFF
INT
ATW1
OFF
AUTO L
••••I••••
••••
I••••...

Page 45

INSTALLATION
■Mounting the Camera
Ceiling mount
The figure shows an example of the camera mounted
on a ceiling with a locally procured bracket.
Refer to the instructions included with the bracket for
filling gaps and holes with waterproof material.
Sun Shield
Use the optional WV-7176E Sun Shield to protect the
camera from direct sunlight. See instructions included
with the sun shield.
-45-
Precautions
•The following steps of installation and connection work should be done by qualified service personnel...

Page 46

-46-
1. Preparations
(1) Procure a ceiling mount bracket.
(2) Installation Surface
CAUTION:Consult an expert on the load bear-
ing capacity of the installation surface and
structure. If the surface is not strong enough,
the camera may fall down. Refer to the prod-
uct specifications for weights.
Prepare appropriate hardware (e.g. wall nuts,
anchor bolts, etc.) for fixing on the installation
surface.
2. Disassembling the Camera
(1) Remove the upper base from the camera by
loosening 3 screws. Turn the...

Page 47

-47-
4. Setting the Switches
The 8-bit DIP switch has two functions.  It is used to
restore the factory default settings and to specify the
unit number.  Before setting, peel off the seal cover-
ing the switch holes. After setting the switch, replace
the seal.  The 4-bit DIP switch selects termination
ON/OFF and half/full duplex for RS485 communica-
tion.  The switch settings are read into the camera
when the power is turned on.  After changing the
switch settings, be sure to turn the power off, then...

Page 48

-48-
Unit Number
Switch 1, an 8-bit DIP switch, specifies the unit number or restores the factory
default settings when using the Panasonic protocol.
When the switch position corresponding to the unit number 1-96* is selected,
setting should be made on the RS485 SET UP menu (see page 43).
For Panasonic’s Protocol
1234 ON5678
Switch positionUnit
number
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234...

Page 49

-49-
1234 ON5678
Switch positionUnit
number
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
Switch positionUnit
numberSwitch positionUnit
number
69
70
71
72
73
74
75
76
7778
79
80
81
82
83
84
85
8687
88
89
90
91
92
93
94
951234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678
1234 ON5678 

Page 50

-50-
Notes:
•Defaults are marked with *.
•BP stands for Bit Position.
•Full duplex is not available in a daisy chain connec-
tion. (Panasonic system controllers only)
5. Mounting the camera
(1) Aim the START arrow at the bent portion of the
leaf spring.(2) Be sure to hook the fall prevention wire into the
bracket.
(3) Fix the camera to the upper base.
•Move the camera up so that its guide pins fit
into the guide holes of the upper base.
•Turn the camera counter-clockwise to the
end, viewed from the...