Have a look at the manual Panasonic Central Processing Unit Wj Mpu955a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
61 Camera Function (Shortcut Function) The following function is available only when specified cam- eras with the camera function feature are used. This function enables executing camera functions via a shortcut. 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. Enter the desired camera function number by pressing the numeric buttons. Note:When you select a wrong number, press the CLEAR button to clear the numeric input. 3. Pres the CAM FUNC/SYS FUNC button. CamF:nnn will appear on the LCD. Note:Refer to Operating Instructions of camera for details on available shortcuts. Other Camera Functions The following functions are available. •Camera setup (p. 78) •Auto mode (p. 78) •BW mode (p. 78) •Patrol learn (p. 79) MON 75 CAM 0123 Unit:01 00512 MON CamF:075 CAM 0123 Unit:01 00512 Camera Function Control
62 Running Sequence Tour Sequence The following functions are available if a Tour Sequence has been previously configured through the admin console. Any Tour Sequence can be assigned to any monitors. 1. Select the desired monitor. (Refer to p. 56 Monitor Selection.) 2. To select the desired Tour Sequence number, press the numeric buttons. Note: When you have selected a wrong number, press the CLEAR button to clear the numeric input. 3. Press the TOUR SEQ/GROUP SEQ button. The Tour Sequence will run in forward direction on the active monitor, and the Tour Sequence number with R (Running) sign is displayed on the active monitor. Note: The messages on the LCD indicate the following. Annn:Area No. Tnnnn:Tour Sequence No. R:Running 4. To pause the sequence, press the SEQ PAUSE/SEQ STOP button. The P (Pausing) sign will be displayed beside the Tour Sequence number area on the active monitor, and P will appear beside the Tour Sequence number. Notes: •To switch to the next sequence step, press the + button during sequence pause. •To switch to the previous sequence step, press the – button during sequence pause. •To resume the sequence, press the TOUR SEQ/GROUP SEQ again. 5. To return to spot monitoring, press the SEQ PAUSE/SEQ STOP button while holding down the SHIFT button. Note: You can also return to spot monitoring by select- ing a camera. Group Sequence The following function is available only if a Group Sequence has been previously established through the admin console. A Group Sequence determines the assignment of monitors and cameras. 1. Press the numeric buttons to select a desired Group Sequence number. Note:When you have selected a wrong number, press the CLEAR button to clear the numeric input. 2. Press the TOUR SEQ/GROUP SEQ button while holding down the SHIFT button. The Group Sequence will run in forward direction on the assigned monitors, and the Group Sequence number with R (Running) sign is dis- played on each monitor. Notes: •The messages on the LCD indicate the following. Annn:Area No. Gnnnn:Group Sequence No. R:Running •When you select another monitor and starts a group sequence, the Group Sequence number will not be displayed on the LCD. 3. To pause the sequence, select one of the monitors that are being run on the selected group sequence. Then press the SEQ PAUSE/SEQ STOP button. The P (Pausing) sign will be displayed beside the Group Sequence number area on the active monitor. Notes: •To switch to the next sequence step, press the + button during sequence pause. •To switch to the previous sequence step, press the – button during sequence pause. 4. To return to spot monitoring, select one of the monitors that are being run on the selected group sequence. Then, press the SEQ PAUSE/SEQ STOP button while holding down the SHIFT button. MON 1 CAM 0123 Unit:01 00512 MON A001T0001R CAM 0123 Unit:01 00512 MON A001T0001P CAM 0123 Unit:01 00512 MON 1 CAM 0123 Unit:01 00512 MON A001G0001R CAM 0123 Unit:01 00512 MON A001G0001P CAM 0123 Unit:01 00512
63 Note:You can also return to spot monitoring by select- ing a camera. Notes: •Group sequences should contain group presets with the same group of monitors. •If two or more group sequences are assigned to the same monitor, only one group sequence can run at a time. •Group sequences do not support the switchover and restore functions.Call Group Preset Refer to p. 78 Menu Function Details for how to operate. Number of characters displayed on the monitor screen dif- fers depending on systems. •GX System (NTSC model only), System850:40 x 16 characters •WJ-SX650 512 x 64 Full Matrix System:38 x 14 char- acters The following are examples of WJ-SX650 512 x 64 Full Matrix System monitor display. On-Screen Display Control The procedure described below lets you determine the dis- play, such as camera title, clock and status, on and off on the active monitor screen. Note:The following functions are not available when the on-screen displays are compounded from the Character Board that is installed on the Camera Input Board. Confirm the setting in the admin consolefor details. 1. Select the desired monitor. (Refer to p. 56 Monitor Selection.) 2. Press the OSD button. The OSD items (camera ID, monitor status, and general status) will be hidden from the monitor.Notes: •Every time you press the OSD button, the OSD items will be displayed or hidden. When the OSD items are displayed, the LCD display will become as follows. •You cannot display or hide the clock (time and date) by pressing the OSD button. Refer to p. 79 OSD Control. •To display or hide each OSD item individually, refer to p. 79 OSD Control. Alarm History Table Refer to p. 66 Alarm History Table. Alarm Status Table Refer to p. 80 Alarm Status Table. Video Loss Status Table Refer to p. 80 Video Loss Status Table. System Status Table Refer to p. 81 System Status Table. Video Loss History Table Refer to p. 81 Video Loss History Table. Monitor Display Control MON OSDAll Off CAM 0123 Unit:01 00512 07/07/1999 03:37:21 PM M AREA1 ALM T R A C CAMERA TITLEClock General status Monitor status Camera ID MON OSDAll On CAM 0123 Unit:01 00512
64 Alarm Control Alarm Selection To control alarm behaviors, you need to select a desired alarm number. 1. Select a desired alarm number by pressing the numer- ic buttons. 2. Press the ALARM/ALM SUSPEND button. The current status of selected alarm will be displayed on the LCD. Armed:The system is armed for alarm response. Active:Alarm has been triggered and activated assigned alarm response. Ack:Alarm is acknowledged and an operator can con- trol the alarm action. Reset:Activated alarm is reset, but the alarm device is still active. Disarm:The system is disarmed for alarm response. Clear:Auto arming is not set in the admin console. 3. To select the next alarm number, press the + button. To select the previous alarm number, press the – but- ton. Alarm Arming Control 1. Select a desired alarm. (Refer to Alarm Selection.) 2. Every time you press the ALARM/ALM SUSPEND but- ton, the selected alarm will be armed or disarmed. When an alarm is disarmed, the LCD display will become as follows. 3. To exit the alarm mode, press the CLEAR button. The LCD display will become as follows. MON 1 CAM 0123 Unit:01 00512 MON Alarm00001 CAM 0123 Armed 00512 MON Alarm00001 CAM 0123 Disarm 00512 MON Alarm Exit CAM 0123 Unit:01 00512 Example of Alarm Input and Resulting Alarm Activation The following is an example of an alarm input and the resulting alarm activation. Basic Setup Note:Refer to the Admin ConsoleUsers Guide for details on setup. •Alarm Input #1 activates Gseq (Group Sequence) #1 as Alarm Action #0. The Group Sequence has priority 12. •Monitor #1, #2, #3 and #4 are assigned to run the sequence. •The target monitor is Monitor #5. The images are dis- played in the hold mode. •Monitor #5 displays the images of Camera #5 in spot mode. Alarm Behaviors 1. Alarm #1 is activated. 2. Monitor #5 displays the alarm indication ALM, A1 (Alarm #1), and -0 (Action #0) to indicate that Alarm #1 is activated. (Refer to the illustration.) 3. Gseq (Group Sequence) #1 runs on Monitor #1, #2, #3 and #4 with the lowest priority (Refer to the illustration.). 4. You will select Alarm #1. 5. You will press the ALARM/ALM SUSPEND button, and then press the ALM RESET/ALM ALL RESET button. Alarm #1 will be reset, and ALM will disappear from Monitor #5. (However, GSeq #1 continues to run on the monitors.) 6. To stop the sequence on the monitors, you will select one of the monitors by pressing the MON (ESC) button. Then, you will press the STOP button. M1 G1 R Group Sequence Monitors Target Monitor M2 G1 R M3 G1 RM4 G1 RM5 ALMA1-0
65 To arm or disarm all alarms Every time you press the ALARM/ALM SUSPEND but- ton while holding down the SHIFT button, all alarms will be armed or disarmed. Note:To arm or disarm an alarm, activate Allow Disarm for the alarm. (Refer to the Admin ConsoleUsers Guide for details.) To Operate Alarm-related Camera (ACK) You can operate the camera associated with the alarm action as follows: 1. Perform Step 1 and 2 of Alarm Selection. 2. Enter a desired alarm action number by pressing the numeric buttons. Note:If you skip this step, Alarm Action #0 will be specified. 3. Press the ACK button. Ack:nn will appear on the LCD. 4. Control the cameras with the system controller. (Refer to p. 58 Camera Site Accessories Control.) Note:To select another alarm, press the ALARM/ALM SUSPEND button. The ACK status will be canceled (cancelled). Then, enter the alarm action number by pressing the numeric buttons, and press the ALARM/ALM SUSPEND button again. MON CAM 0123 ALL Arm 00512 MON CAM 0123 ALLDisarm 00512 MON 9 CAM 0123 Active 00512 MON Alarm00001 CAM 0123 Ack:9 00512 To Cancel Alarms 1. Perform Step 1 to 2 of p. 64 Alarm Selection. 2. Press the ALM RESET/ALM ALL RESET button to reset the alarm. Reset will be displayed on the LCD. Notes: •To reset all the alarms at a time, press the ALM RESET/ALM ALL RESET button while holding down the SHIFT button. •After the alarm is deactivated, Armed or Cleared will be displayed on the LCD. MON Alarm00001 CAM 0123 Reset 00512 MON Alarm00001 CAM 0123 ALL Reset 00512 MON Alarm00001 CAM 0123 Armed 00512 MON Alarm00001 CAM 0123 Cleared 00512
66 Alarm History Table There are 1000 alarm records stored in chronological order in 125 pages of table. 1. Select a desired monitor. (Refer to p. 56 Monitor Selection.) 2. Press the ALM RECALL button. AlarmHist will appear on the LCD, and the ALARM HISTORY table will be dis- played on the active monitor. ALM:Logical alarm number STATE:Indicates alarm state changes. ARMED:The system is armed for alarm response. ACTIVE:Alarm has been triggered and activated assigned alarm response. ACKED:Alarm is acknowledged and an operator can control the alarm action. RESET:Activated alarm is reset, but the alarm device is still active. DISARMED:The system is disarmed for alarm response. CLEARED:Auto arming is not set in the admin con- sole. DATE/TIME:Date and time when alarm state changes. 3. To display the next page, press the + button. To display the previous page, press the – button. Notes: •To display the first page of table, press the + but- ton while holding down the SHIFT button. •To display the last page of table, press the – button while holding down the SHIFT button. •Every time you press the button 0 while holding down the MON (ESC) button, the monitor back- ground will change beween camera images and black picture. 4. To exit the ALARM HISTORY table, press the CLEAR button while holding down the MON (ESC) button. MON AlarmHist CAM 0123 00512 ALARM HISTORY PG ALM STATE DATE/TIME 1 DISARMED 01/01/01 12:00 1 ARMED 01/01/01 12:00 1 ACTIVE 01/01/01 12:00 1 ACKED 01/01/01 12:00 1 CLEARED 01/01/01 12:00 1 RESET 01/01/01 12:00
67 WJ-HD300A Series Control Central Processing Unit WJ-MPU955A can control Digital Disk Recorder WJ-HD300ASeries. Recorder Selection To control this recorder, you need to perform the operations described in Recorder Selection. You can select a recorder by performing either of the fol- lowing. •Recorder auto selection •Recorder manual selection Recorder Auto Selection 1. Select a camera whose picture you wish to play back. (Refer to p. 56 Camera Selection.) 2. Press the PLAY/PAUSE button. The recorder connected to selected camera will auto- matically selected, and playback will start. 3. Control the recorder. (Refer to Controlling Digital Disk Recorder WJ-HD300ASeries.) Note:When you press the STOP button, the monitor display is changed to the live images. 4. To resume normal camera selection, select a camera while live images are being displayed on the monitor. Recorder Manual Selection 1. Enter a desired recorder number by pressing the numeric buttons. 2. Press the RECORDER/UNIT button. 3. Control the recorder. (Refer to Controlling Digital Disk Recorder WJ-HD300ASeries.) 4. To resume normal camera selection, select a camera while live images are being displayed on the monitor. Displaying WJ-HD300ASeries SETUP MENU Refer to p. 78 Menu Function Details. Controlling Digital Disk Recorder WJ-HD300ASeries The following are the operating procedures of WJ-HD300A Series via system controller. Note:Refer to the Operating Instructions of recorder for details on each function. Normal Playback 1.Select the recorder. (Refer to Recorder Selection.) 2. Press the PLAY/PAUSE button. To start the playback, press the PLAY/PAUSE button. The recorded image will be played back. Note:If you have performed Recorder Auto Selection, skip this step. 3. Perform desired operations. •To pause the playback, press the PLAY/PAUSE button. •To stop the playback, press the STOP button. •To resume the playback, press the PLAY/PAUSE but- ton. •To move forward/backward search during the play- back, move the shuttle ring clockwise or counterclock- wise. Shuttle ring clockwise:Fast-forward playback Shuttle ring counterclockwise:Rewind playback Shuttle hold button:If you press this button while rotating the shuttle ring, playback speed will be main- tained even after removing a hand from the shuttle ring. (The LED indicator on this button blinks during the fast playback.) • To move forward/backward field advance during the pause, move the JogDial clockwise or counterclockwise. JogDial clockwise:Forward field advance JogDial counterclockwise:Backward field advance •To skip to the next/previous record during the play- back, move the JogDial clockwise or counterclockwise. JogDial clockwise:Skips to the next record. JogDial counterclockwise:Skips to the previous record. MON DVR 0123 Unit:01 >00512 MON DVR 0123 Unit:01 >00512 MON CAM 0123 Unit:01 >00512
68 •To display the spot playback picture, press the numer- ic button corresponding to the desired channel num- ber, then press the ENTER button. Then, the active camera number will appear on the LCD. •To select the next channel number, press the + button. •To select the previous channel number, press the – button. Multiscreen Segment Switching 1. Select the recorder. (Refer to p. 67 Recorder Selection.) 2. Press the MULTI SCREEN button. Every time you press the button, the multiscreen segment patterns are switched. 4 segments (1 - 4 CH) →4 segments (5 - 8 CH) →4 segments (9 - 12 CH) →4 segments (13 - 16 CH) →7 segments (1 - 7 CH) →9 segments (1 - 9 CH) →9 seg- ments (10 -16 CH) →10 segments (1 - 10 CH) →13 segments (1 - 13 CH) →16 segments (1 - 16 CH) 3.To return to the spot display, press the numeric button corresponding to the desired channel number. Then, press the ENTER button, or press the CAM (SET) but- ton while holding down the SHIFT button. Electronic Zooming (EL-ZOOM) Playback images can be electrically zoomed besides a cameras optical zooming. 1. Select the recorder. (Refer to p. 67 Recorder Selection.) 2. Press the PLAY/PAUSE button. To start the playback, press the PLAY/PAUSE button. The recorded image will be played back. Note:If you have performed Recorder Auto Selection in p. 67, skip this step. 3. Select the desired channel number by pressing the numeric buttons. 4. Press the ENTER button. The selected channel s picture is displayed in the spot mode. 5. Each time the EL-ZOOM button are pressed, the zoom- ing range are changeable as follows: 2x →4x →1x →2x … Note:You can move the zoomed area on the monitor by moving the 3D joystick. A-B Repeat Playback Refer to p. 76 A - B Repeat Playback. Playing the Latest Recorded Image 1. Select the recorder. (Refer to p. 67 Recorder Selection.) 2. Press the PLAY/PAUSE button. To start the playback, press the PLAY/PAUSE button. The recorded image will be played back. Note:If you have performed Recorder Auto Selection in p. 67, skip this step. 3. Press the GO TO LAST button during the playback. The latest recorded image will be played back. MON DVR 0123 Unit:01 >00512
69 Manual Recording 1.Select the recorder. (Refer to p. 67 Recorder Selection.) 2. Press the REC button. Recording will start. 3. To stop the recording, hold down the REC button for 2 seconds. Note:Refer to the Operating Instructions of recorder for details and other recording modes. Marking 1.Select the recorder. (Refer to p. 67 Recorder Selection.) 2. Press the PLAY/PAUSE button. To start the playback, press the PLAY/PAUSE button. The recorded image will be played back. Note: If you have performed Recorder Auto Selection in p. 67, skip this step. 3. Press the MARK button during the playback. The play- back start point will be marked. Note: The marked playback images will be listed in the marking list window. Refer to p. 73Marking search for how to play back. Search Playback You can search recorded images through the date and time. Every time you press the SEARCH/T&D SEARCH button, the monitor display will change as follows. Live image →Date-and-time entry form →Recording event list →VMD search list →Marking list →Date-and-time entry form… The following are the details on LCD display patterns and function buttons. LCD display while the event list is displayed on the monitor LCD display while the thumbnail menu is displayed on the monitorNote:While holding down the SHIFT button, the LCD dis- play will become as follows. Available buttons and functions (Common) F1 button:Thumb or List Changes the monitor display between the recording event list window and thumbnail menu. F3 button:Text Displays text information of selected event on the recording event list. F4 button:Copy Displays the DATA COPY window while the recording event, VMD search, or making list window is displayed. F1 button while holding down the SHIFT button:Nr-A Specifies the normal or event recording area for the playback media. F2 button while holding down the SHIFT button:Cp-A Specifies the copy area for the playback media. F3 button while holding down the SHIFT button:Cpy1 Specifies the external recording device connected to the COPY1 port of recorder. F4 button while holding down the SHIFT button:Cpy2 Specifies the external recording device connected to the COPY2 port of recorder. Notes: •The monitor display is not changed even if pressing the F1 button while the date-and-time entry form is dis- played. •To close the monitor display activated by the function buttons, press the MON (ESC) button. •The DATA COPY window is not displayed while a thumbnail window is displayed. •Refer to the operating instructions of recorder for details on each function. Search Mode /HD300 Thumb Text Copy F1 F2 F3 F4 Search Mode /HD300 List Text Copy F1 F2 F3 F4 Search Mode /HD300 Nr-A Cp-A Cpy1 Cpy2 F1 F2 F3 F4
70 Available buttons and functions (Text information) CAM (SET), MON (ESC), or EXIT button:Returns to the upper menu. Note:Text editing is not available. Available buttons and functions (DATA COPY window) JogDial clockwise:Increments a parameter. JogDial counterclockwise:Decrements a parameter. CAM (SET) button:Executes the selection and starts data copy. (If OK is selected) / Cancels the selec- tion and returns to the upper menu. (If CANCEL is selected) MON (ESC) or EXIT button:Cancels the selection and returns to the upper menu. 3D joystick upward (D):Moves the cursor up. 3D joystick downward (C):Moves the cursor down. 3D joystick leftward (A):Moves the cursor to the left. 3D joystick rightward (B):Moves the cursor to the right. Date-and-time Search Playback The recorded images can be searched for through the date and time. 1. Select the recorder. (Refer to p. 67Recorder Selection.) 2. Press the SEARCH/T&D SEARCH button repeatedly until the date-and-time entry form appears on the moni- tor. The date-and-time entry form will appear on the center (centre) of monitor. 3. Enter the desired date and time by performing either of the following. •Rotate the JogDial clockwise or counterclockwise. •Press the + or – button. The cursor can be adjusted by moving the 3D joystick to the right or left. 4. Press the PLAY/PAUSE or CAM (SET) button. After the search through the date and time, the recorded image will be played. 5. To exit the entry form, press the MON (ESC) or EXIT button. The live image will be displayed again on the monitor. Recording event search You will select a searching filter from TIME&DATE, CAM- ERA, REC EVENT, and TEXT. Playback pictures will be searched by the selected searching filter. 1. Select the recorder. (Refer to p. 67Recorder Selection.) 2. Repeat pressing the SEARCH/T&D SEARCH button until the recording event list window is displayed on the monitor. The recorder will enter the searching mode. 3. Select a desired searching filter by moving the joystick rightward or leftward. Note: The illustration is an example in which CAMERA has been selected for the searching filter. 4. To determine the filter setting, press the CAM (SET) but- ton. The searching filter window will be displayed on the monitor. Note:The searching filter window differs depending on the searching filter selected in Step 2. Refer to p. 71 Searching filter windows for details on each win- dow. 5. Filter recording events. (Refer to p. 71Searching filter windows.) 6. To exit the searching filter window, press the MON (ESC) button. The searching filter window will be closed, and the recording event list window will be dis- played again on the monitor. Note:Refer to Step 3 for the screenshot. TIME&DATE SEARCH REC EVENT SEARCH VMD SEARCH MARK START ..::FEB 2 0412 00 00 AM TIME&DATE 01ch 01ch 01ch 01ch 01ch 01ch 01ch 01chMANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL CAM REC EVTABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOPTEXT APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM TIME&DATE SEARCH REC EVENT SEARCH VMD SEARCH MARK TIME&DATECAMERAREC EVENTTEXTUNLOCK FILTER TOTAL APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM100 TIME&DATE 01ch 01ch 01ch 01ch 01ch 01ch 01ch 01chMANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL MANUAL CAM REC EVTABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOP ABCDEFGHIJKLMNOPTEXT APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM TIME&DATE SEARCH REC EVENT SEARCH VMD SEARCH MARK TIME&DATECAMERAREC EVENTTEXTUNLOCK FILTER TOTAL APR.25.03*12:34:56 AM APR.25.03*12:34:56 AM100 1 2345678 91011 12 13 14 15 16 CAMERA FILTERINGCAMERA SET : [ SET ] CANCEL : [ ESC ]