Have a look at the manual Panasonic Central Processing Unit Wj Mpu955a Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
51 ID 1Area 0Priority 3Boot File –Model WV-CU950IPA 172.18.0.200EA 00:80:45:0D:D0:01Port 0 ID CONTROLLERS Note:Actual MAC address that is indicated on a product should be entered in the EA field. 1 2 3 4 5 6 7 8Area 0 0 0 0 0 0 0 0Local 1 2 3 4 5 6 7 8Switch GX GX GX GX GX GX GX GXPort 1 2 3 4 5 6 7 8 MONITORS OPERATORS Timeout ID 100 955Password 100 955Priority 100 300:00:00 00:00:00Name Normal SuperClass 1: Normal 2: Super
52 DIGITAL RECORDERS 1 15 16 14 13 109 7 12 116 1 2 3 4 5 8 ID Logical 1Model WJ-HD316AVideo Switch Port GX16IPA 172.18.0.60Unit Address 1Digital Bitrate 6.144 Channels 15 – 14 13 109 7 12 116 1 2 3 4 5 8 Cam
54 LCD Display Descriptions Default Status (LCD Display After Login) qMonitor number The number of connected monitor is displayed. wUnit number/Status The number of connected site will be displayed. eCamera number The number of selected camera is displayed. rInput number/Recorder number/Status The numeric input, selected recorder number, or status is displayed. Blinking In this document, grayed (greyed) areas on the LCD illus- trations mean blinking. Messages Displayed on the LCD The following are examples of LCD display after login. Note:Some parts of LCD displays, described on this docu- ment, may differ from the actual status. Invalid This message is displayed in the following circumstances. •When you have entered a wrong user ID or password, etc. •When you have entered a camera number or monitor number, etc. that is not existing. Busy •When a selected monitor is controlled by a higher-level user, ∗ blinks on the LCD. (You cannot control the monitor.) •When a selected camera is controlled by a higher-level user, ∗ blinks on the LCD. (You cannot control the camera.) •To cancel the Busy status, select another monitor, cam- era, or wait until ∗ goes out. Prohibit (Prohibited) •When you have tried an operation not authorized by the system unit, Prohibited is displayed on the LCD. •When you have forgotten to select a monitor before selecting a camera, Prohibited is displayed on the LCD. •After a few seconds, the LCD display will return to the default status. MON Invalid CAM 0001 Unit:01 00001 MON Prohibit CAM∗ 0001 Unit:01 00001 Busy status is activated for a camera. ∗MON Prohibit CAM 0001 Unit:01 00001 Busy status is activated for a monitor. MON Prohibit CAM 0001 Unit:01 00001 ∗MON Prohibit CAM 0001 Unit:01 00001 Blinking MON CAM 0032 Unit:01 >00512
55 Operation Start (Login) 1. Turn on the power switches of all system components. 2. Turn on the power of system controller. (Refer to the Operating Instructions.) The OPERATE indicator will light up, and the following message will appear on the LCD. Note:Wait unitl the following display appears on the LCD. 3. Enter the ID number by pressing the numeric buttons. Then, press the CAM (SET) button. PWD will appear on the LCD. Note:When you have entered a wrong ID number, press the CLEAR button. 4. Enter the password by pressing the numeric butons. 5. Press the CAM (SET) button. When the password is correct, OK will apear for 2 seconds on the LCD. Note:When the password is wrong, NG will appear for 2 seconds on the LCD. In this case, retry the login procedure. Login and Logout Note:If you perform the login procedure after resetting the CPU unit or turning on the power of CPU unit, the LCD display may return to Step 2. In this case, wait for approx. 5 minutes until the CPU unit has been started up. Then, retry the login procedure. Operation End (Logout) You need to log out of the system: •When leaving the controller •When system access is no longer required 1. During the login status, press the MON LOCK/LOGOUT button while holding down the SHIFT button. 2. You will log out of the system, and the LCD display will return to the login standby display. ID Display Function You can check the following on the LCD. (Refer to p. 82 for how to display.) •Operator ID •Controller ID •System version ID: Unit:01 ID:12345 PWD: ID:12345 PWD:∗∗∗∗∗ MON PWD:OK CAM Unit:01 ID: Unit:01 ID:12345 PWD:NG Connecting to Main CPU ...
56 After the login procedure, the following operations are avail- able to control the system. The operation begins with monitor selection. Then, the image of selected camera appears on the active monitor. Monitor Selection 1. Select the desired monitor number by pressing the numeric buttons. The entered number will appear on the LCD. 2. Press the MON (ESC) button. When the selected monitor number is correct, < is dis- played. Note:To select the next or previous monitor number, press the + or – button. Camera Selection 1. Select the desired camera number by pressing the numeric buttons. The entered number will appear on the LCD. 2. Press the CAM (SET) button. When the selected camera number is correct, > is dis- played. Note:To select the next or previous camera number, press the + or – button. Monitor Selection and Camera Selection Monitor Lock Monitor lock is the function to retain other operators control of a monitor even after that operator has selected another monitor. Note:This function will prevent operators with a lower prior- ity from gaining control of a monitor. However, opera- tors with a higher or the equal priority can gain the con- trol of monitor. 1. Select a desired monitor. (Refer to Monitor Selection.) 2. Press the MON LOCK/LOGOUT button. The monitor lock mode is activated, the monitor number with L sign is displayed on the active monitor, and L will appear beside MON on the LCD. Note:Every time you press the MON LOCK/LOGOUT button, the monitor lock mode will be activated or deactivated. MON 123 CAM Unit:01 MON CAM 0123
57 Adjustment of LCD Display and Buzzer You can perform the settings of LCD brightness, LCD contrast, alarm buzzer, or button buzzer. (Refer to WV-CU950 Operating Instructions for how to adjust.) Display Setting for Controller
58 Camera Site Accessories Control Lens Control Notes: •Check that a specified lens, with motorized zoom/focus functions, is mounted on the camera, and the lens selection (DC/VIDEO) on the camera is set to DC. •Available functions differ depending on cameras. Refer to the Operating Instructions of camera. 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. Press the FOCUS FAR or NEAR button while watching the monitor. The lens focus is adjusted to obtain a sharply focused image. Note:Pressing the B button or top button of 3D joystick unit can also set the lens focus automatically. 3. To adjust the lens zoom, move the zoom wheel con- troller to the right (TELE) or left (WIDE). 4. Press the IRIS OPEN or CLOSE buttons to open/close the lens iris. The lens iris is adjusted by these buttons to obtain the proper image exposure.Note:To return the lens iris to the factory default status, press the A button of 3D joystick unit. Pan/Tilt Control Manual Operation 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. Move the 3D joystick to move the pan/tilt head towards the desired direction. Notes: •If you move the 3D joystick widely, you can pan and tilt the camera faster. •Panning/tilting speed differs depending on cameras. Auto Panning Refer to p. 78 Auto Mode for how to operate. Program Preset Position 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. To move the camera to the position to be preset, move the 3D joystick and press the lens control buttons. 3. To select the desired preset position number, press the numeric buttons. Notes: •When you have selected a wrong number, press the CLEAR button to clear the numeric input. •WJ-MPU955A supports up to 255 preset positions. FA R FOCUS NEAR B Top button WIDE TELE Zoom wheel controller OPEN IRIS CLOSE A MON 15 CAM 0123 Unit:01 00512
59 4. Press the PRESET/PGM PRESET button while holding down the SHIFT button. The preset position will be saved. Note:If the entered position number has stored the previ- ous preset position, it will be overwritten by the new one. Call Preset Position 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. To select the desired preset position number, press the numeric buttons. Notes: •When you have selected a wrong number, press the CLEAR button to clear the numeric input. •WJ-MPU955A supports up to 255 preset positions. 3. Press the PRESET/PGM PRESET button. The camera will move to the preset position, and the image of selected preset position will be displayed on the active monitor. Note:To call preset positions, you must set preset position numbers for the camera in advance. Wiper Control The following procedure is available when a selected cam- era (housing) is equipped with a wiper. 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. Keep pressing the WIPER button. The wiper will be activated while this button is being pressed. Note:When the WIPER button is released, the LCD dis- play will become as follows. MON PrgPre:15 CAM 0123 Unit:01 00512 MON 15 CAM 0123 Unit:01 00512 MON Preset:15 CAM 0123 Unit:01 00512 MON Wiper On CAM 0123 Unit:01 00512 MON Wiper Off CAM 0123 Unit:01 00512
60 Defroster Control The following procedure is available when a selected cam- era (housing) is equipped with a defroster. 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. Pressing the DEF ON/OFF button. The defroster will be activated. 3. To deactivate the defroster, press the DEF ON/OFF button while holding down the SHIFT button. Note:The defroster will be automatically deactivated when the temperature reaches the specified degrees. Auxiliary Control You can control one or two auxiliary control devices. The following procedure is available when an auxiliary control device, such as Receiver WV-RC150, is connected to a system unit. Operating Procedure 1. Select the desired monitor and camera. (Refer to p. 56 Monitor Selection and Camera Selection.) 2. Press the AUX 1 ON/OFF or AUX 2 ON/OFF button. The auxiliary control device, associated by the installa- tion wiring, will be activated. 3. To quit the auxiliary control, press the AUX 1 ON/OFF or AUX 2 ON/OFF button while holding down the SHIFT button. MON Aux1 On CAM 0123 Unit:01 00512 MON Aux2 On CAM 0123 Unit:01 00512 MON Aux1 Off CAM 0123 Unit:01 00512 MON Aux2 Off CAM 0123 Unit:01 00512 MON Def Off CAM 0123 Unit:01 00512 MON Def On CAM 0123 Unit:01 00512