Page 91

91
7
Chapter 7  Menu description tables
7-5-8 IRIS
7-6 FILE
7-6-1 CARD READ/WRITE
TITLE1 - 8:For setting a title consisting of not more than
8 characters.
ItemVariable
rangeRemarks
R.SELECT1: 8
For selecting the number of the file whose
data is to be read.
READFor reading the data on the setup card.
WRITEFor writing the camera data onto the setup
card.
W.SELECT1: 8
For selecting the number of the file in which
the data is to be written.
CARD CONFIGFor formatting the setup card.
TITLE READFor reading the...

Page 92

92
Chapter 7  Menu description tables
7-6-3 LENS FILE
ItemVariable
rangeRemarks
FILE NO.1: 8
For selecting the number of the lens file.
READFor reading the data from the lens file.
WRITEFor writing the data in the lens file.
TITLE 1-8 ************For setting a title consisting of not more than
12 characters.
7-6-4 SCENE
TITLE 4FILM LIKEFor creating the scene file title.  As the initial
value and after resetting, the title and also the
data are set to FILM LIKE.
ItemVariable
rangeRemarks
READ USER DATAFor...

Page 93

93
7
Chapter 7  Menu description tables
7-8 VTR MENU
7-8-1 VTR FUNCTION
ECU REC CHK SWR.REVIEW
RETAKEFor setting the unit’s operation to be
performed using the REC check button on the
ECU.
R.REVIEW:The rec review operation is
performed.
RETAKE:The retake operation is
performed, after which playback
is initiated automatically.
ItemVariable
rangeRemarks
HUMID OPE ONOFFFor selecting whether or not to continue
operation when HUMID alarmstate has
occurred.
REC START ALLNORMALFor selecting how recording start...

Page 94

94
Chapter 7  Menu description tables
BATTERY SELECT AJ-BP490
AU-BP402
HP-30A
PRO14
TRIM14
HYTRON50
HYTRON100
DIGITAL14
DIGITAL13
DIONIC
BP-H120
NP-L50
NP-L50D
ENDURA50
ENDURA80
BP-L60/90
NP-1B
TYPE A
TYPE B
For selecting the type of battery to be used.
The remaining charge is detected in
accordance with the battery which has been
selected.
The variable range is changed by the item
settings selected on the “7-8-3 BATTERY
SETTING1” and “7-8-4 BATTERY
SETTING2” menus.
Note that the initial value for TYPE...

Page 95

95
7
Chapter 7  Menu description tables
TRIM14¢
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
¢:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0: 13.6: 15.0
For selecting, when MANUAL has been
selected as the setting for the menu item above,
in 0.1 V steps the voltage at which...

Page 96

96
Chapter 7  Menu description tables
ItemVariable
rangeRemarksItemVariable
rangeRemarks
7-8-4 BATTERY SETTING2
BP-L60/90¢
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
¢:The selection is enabled.
/:The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:The voltage is set automatically.
MANUAL:The voltage is set manually.
11.0: 11.0: 15.0
For selecting, when MANUAL has been
selected as...

Page 97

97
7
Chapter 7  Menu description tables
7-8-5 MIC/AUDIO1
TEST TONENORMAL
ALWAYS
OFF
CHSELFor selecting the test signal.NORMAL:The test tone signal is output to all
the channels when the CAM/BAR
switch has been set to BAR and the
CH1 AUDIO IN switch has been set
to FRONT.
ALWAYS:The test tone signal is always output
to all the channels when the CAM/
BAR switch has been set to BAR.
OFF:The test tone signal is not output.
CHSEL:The test tone signal is output to the
channels for which the CH1 or CH2
AUDIO IN...

Page 98

98
Chapter 7  Menu description tables
The underlining in the variable range column indicates the setting in the preset mode.
ItemVariable
rangeRemarks
7-8-7 TC/UB
ItemVariable
rangeRemarks
UB MODEUSER
TIME
DATE
EXT
TCG
FRM RATE
REGENFor selecting the UB mode.
USER:Selects the UB value set in the
LCD section.
TIME:Selects the local time (hour,
minute, second).
DATE:Selects the local date and time
(last 2 digits of year, month, date,
hour)
EXT:Sets the UB from the TC-IN as the
slave. The user value is...

Page 99

99
7
Chapter 7  Menu description tables
7-8-8 UMID SET/INFO
DEVICE NODEFor displaying the ID number of the product.
ItemVariable
rangeRemarks
COUNTRYNO-INFOFor inputting the name of the user’s country.
“NO-INFO” is displayed until this is input.
ORGANIZATIONNO-INFOFor inputting the name of the user’s
organization or company.  “NO-INFO” is
displayed until this is input.
USERNO-INFOFor inputting the user’s name.  “NO-INFO” is
displayed until this is input.
7-9 OPTION MENU
7-9-1 OPTION
7-8-9 VTR DIAG...

Page 100

100
Chapter 8  Specifications
Power supply:DC 12 V (11.0 - 17.0 V)
Power consumption:24 W
indicates safety information.
[GENERAL]
Ambient operating temperature:
32 Foto 104 Fo(0 Coto +40 Co)
Storage temperature:
–4 Foto 140 Fo(–20 Coto +60 Co)
Ambient operating humidity:
Within 10% to 85% (relative humidity)
Continuous operation time:
Approx. 120 min. (using the Hytron50 made by
Anton Bauer)
Dimensions (W a a
H a a
D):
5 a8 (excluding handle) a12-5/16 inch
(129 a204 a313 mm)
Weight:
8.6 lbs (3.9 kg)...