Page 71
71 6 Chapter 6 Maintenance and inspections 6-2 Maintenance 6-2-1 Condensation The water vapor in the air may form as tiny droplets on the head drum when the unit is moved from a cold location to a warm location or used in a very humid place. This phenomenon is known as condensation, and running the tape under these conditions is liable to cause the tape to stick to the drum. Note the following points: ≥Remove the tape when the unit’s operation is to be started in conditions where condensation may...
Page 72
72 Chapter 6 Maintenance and inspections 6-2-6 Connectors and signals AUDIO IN 1 GND 2 AUDIO IN(H) 3 AUDIO IN(C) Matsushita part number K1AB103A0007 Maker part number HA16PRM-3SG (Hirose Denki) PUSH 1 3 2 FRONT MIC IN 1 GND 2 AUDIO IN(H) 3 AUDIO IN(C) Matsushita part number K1AB103B0013 Maker part number NC3FBH2 (NEUTRIK) PUSH 1 3 2 DC IN 1 GND 2NC 3NC 4 +12V Matsushita part number K1AA104H0024 Maker part number HA16RX-4P(SW1) (Hirose Denki) 12 3 4 DC OUT 1 GND 2NC 3NC 4 +12V OUT Matsushita part number...
Page 73
73 6 Chapter 6 Maintenance and inspections 6-3 Warning system 6-3-1 Warning description tables When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the WARNING lamp and lamps inside the viewfinder serve to alert the user. Items are displayed in the following sequence of priority: WARNING lamp > tally lamp > warnings inside the viewfinder. The display accords with this sequence when more than one error has occurred at the same time....
Page 74
74 Chapter 6 Maintenance and inspections 6. SERVO 5. HUMID 9. BATTERY NEAR END8. WIRELESS RF 7. RF 10. TAPE NEAR END WARNING lampLights for 90 minutes following the release of the condensation detection after the condensation formation was detected. Indications on LCD screen“HUMID” display lights if condensation is detected. “HUMID” display flashes for an additional 10 to 90 minutes after condensation detection is canceled. Tally lampFlashes 4 times per second for 90 minutes after condensation detection...
Page 75
75 6 Chapter 6 Maintenance and inspections 6-3-3 Emergency eject If the cassette cannot be ejected by pressing the EJECT button, use a screwdriver or similar tool to press and turn the emergency eject screw. This enables the cassette to be removed. 1Set the power to OFF. 4Remove the cassette. 5Return the rubber cap to its original position. 2Remove the rubber cap where shown in the figure. Insert a Phillips head screwdriver into the cross-shaped part of the emergency eject screw (red). 3While pushing...
Page 76
76 Chapter 7 Menu description tables USER MENU USER MENU SELECT SYSTEM SETTING PAINT OPERATION SYSTEM MODE OPTION MODE REC FUNCTION OUTPUT SEL GENLOCK ROP LOW SETTING MID SETTING CAMERA ID SHUTTER SPEED SHUTTER SELECT USER SW SW MODE WHITE BALANCE MODE IRIS FLARE USER SW GAIN MATRIX COLOR CORRECTION SYSTEM(USER) PAINT(USER) VF(USER) OPERATION(USER) FILE(USER) MAINTENANCE(USER) VTR(USER) SKIN TONE DTL KNEE/LEVEL HIGH SETTING ADDITIONAL DTL GAMMA...
Page 77
77 7 Chapter 7 Menu description tables REC TALLYRED GREEN CHARFor selecting the method used to inform the user that the unit is recording when a system using an extender or other device is configured and BOTH is selected as the 26- PIN CONTROL menu item setting while the system is used in the remote control mode. RED:The red tally lamp lights. GREEN:The green tally lamp lights. CHAR:The letters “REC” appear on the viewfinder. ItemVariable rangeRemarks ItemVariable rangeRemarks CAMERA MODE60i 30P 24P...
Page 78
78 Chapter 7 Menu description tables TAKE TOTAL TIMENONE: 5day For setting the time required for shooting. Select a setting from NONE (shooting continues until it is stopped manually) to 5DAY (5 days). NEWS REC MODE (AJ-YA903G not installed)OFF 0.2SEC : 2.0SEC For setting the NEWS REC time. ItemVariable rangeRemarks INTERVAL REC MODEON ONE SHOT OFF For setting the INTERVAL REC function. ON (MEMORY): Interval recording is possible in single- frame units using memory (AJ-YA903G installed). The recording...
Page 79
79 7 Chapter 7 Menu description tables ItemVariable rangeRemarks RETAKE MODE ONOFFFor selecting whether or not to allow retake operations (MODE CHECK switch + RET switch). ItemVariable rangeRemarks VIDEO OUT SELVBS VF Y SDIVBS:Normal composite output. VF:The Y signal of the viewfinder is output as is. It is accompanied by a status display. Y:Component Y output. SDI:SDI output (this setting can be selected only when the SDI option is provided). OUTPUT CHAR TC STATUS MENUONLY For setting the kind of...
Page 80
80 Chapter 7 Menu description tables 7-3-2 MATRIX R GAIN–200: +000: +200 For setting the R channel gain. ItemVariable rangeRemarks MASTER PED–200: +000: +200 For setting the master pedestal level. MASTER DTL–31: +00: +31 For setting the H detail/V detail level. MASTER GAMMA 0.35: 0.45: 0.75 For setting the master gamma in 0.01 steps. KNEE POINT 70.0%: 85.0%: 107.0% For setting the master knee position in 0.5% steps. KNEE SLOPE 0: 50: 99 For setting the knee slope. G GAIN–200: +000: +200 For setting the...