E-10 ENGLISH Parts and functions (Continued) Basic camera operations (Continued) !9GAIN display This displays the image gain of the camera recorder. The initial value is the gain value at the time when the GAIN switch on the camera recorder was set to “L”. !10M.GAIN 3 button When this button is pressed, the image gain of the camera recorder is increased. The lamp is on only when this button is pressed. !11M.GAIN 4 button When this button is pressed, the image gain of the camera recorder is reduced. The lamp is on only when this button is pressed. !12AWB button When this button is pressed, the camera recorder starts the AWB (Auto White Balance) operation. When this button is pressed during AWB operation, the AWB operation will forcibly terminate. The lamp is on during AWB operation and off when the operation is completed correctly. If AWB operation finishes incorrectly, the lamp will flash for 5 seconds and then turn off. !13ABB button When this button is pressed, the camera recorder starts the ABB (Auto Black Balance) operation. When this button is pressed during the ABB operation, the ABB operation will forcibly terminate. The lamp is on during ABB operation and off when the operation is completed correctly. If the ABB operation finishes incorrectly, the lamp will flash for 5 seconds and then turn off. H !9 !12!13 !11 !10 AJ-RC10G.book 10 ページ 2006年7月26日 水曜日 午前9時25分
E-11 Parts and functions (Continued) Basic camera operations (Continued) !14MATRIX ON button This button switches the matrix function ON/ OFF. Even if the MATRIX is set to “OFF” in the menu of the camera recorder, it switches to “ON” when this button is pressed. “A” and “B” of the MATRIX TABLE and the settings for the table can be set with the menu on the unit. The lamp is on when the MATRIX is ON; otherwise, the lamp is off. !15DTL OFF button This button switches the DETAIL function of the camera recorder ON/OFF. Even if the DTL item in the menu of the camera recorder is set to “OFF,” it will turn on when this button is pressed. When the unit is connected to the camera recorder, this becomes the menu value for the camera recorder. The lamp is on when the DETAIL is set to OFF; otherwise, the lamp is off. !16A.KNEE ON button This button switches the AUTO KNEE function ON/OFF. If the AUTO KNEE SW is set to “OFF” in the menu of the camera recorder, it is impossible to turn it ON using this button. When the power is turned on, the unit is in the state it was before turning off the power. The lamp is on when the AUTO KNEE function is ON; otherwise, the lamp is off. !17HIGH COLOR ON button This button switches the HIGH COLOR function ON/OFF. Even if the HIGH COLOR is set to “OFF” in the menu of the camera recorder, it will turn on when this button is pressed. When the unit is connected to the camera recorder, this becomes the menu value of the camera recorder. The lamp is on when the HIGH COLOR function is on; otherwise, the lamp is off. !18SHT ON button This button switches the shutter function ON/OFF. The shutter speed, when this function is on, is selected in the menu of the unit. The lamp is on when the shutter function is on; otherwise, the lamp is off. When the power is turned on, the unit is in the state it was before turning off the power. !14!15!16!17!18 AJ-RC10G.book 11 ページ 2006年7月26日 水曜日 午前9時25分
E-12 ENGLISH Parts and functions (Continued) Volume settings !1VR ACTIVE button This is a button to approve/inhibit operations of the GAIN volumes from !2 to !3 and the BLACK volumes from !4 to !6. When the power of the unit is on, it inhibits operations. The lamp is on when the approving/ operations are activated; otherwise, the lamp is off. !2R GAIN volume This adjusts the Rch gain. The absolute value/relative value mode can be switched in the GAIN-VR-MODE item of the WHITE menu of the unit. When reading card data and scene file data, this will be in the relative value mode. The operations for the B GAIN volume are the same. !3B GAIN volume This adjusts the Bch gain. !4R BLACK volume This adjusts the Rch black level. Switching between the relative value mode and the absolute value mode is executed in the menu BLACK-VR-MODE of the unit. When reading card data and scene file data, this will be in the relative value mode. It is possible to select either Flare or Pedestal for item adjustment in the Menu BLACK-VR-CONTROL item on the unit. The operations for the G BLACK volume and B BLACK volume are the same. !5G BLACK volume This adjusts the Gch black level. !6B BLACK volume This adjusts the Bch black level. !7M.PED volume This adjusts the master pedestal level. The adjustment range is between the minimum value of –200 and the maximum value of +200 with a center value of 0. !8IRIS display This displays the iris of the camera. !9AUTO IRIS button This turns on the auto iris function. When the power is turned on, the unit is in the state it was before turning off the power. The lamp is on when the unit commands the auto iris operation in the camera; otherwise, the lamp is off. !10IRIS volume This adjusts the iris of the camera. When the AUTO IRIS button !9 is set to OFF, it is possible to move the iris from CLOSE to OPEN by turning this to the right. !11EXT alarm lamp This lamp is on when the lens extender is inserted. !1 !2!3 !4!5!6 !7 !11 !8 !10 !9 AJ-RC10G.book 12 ページ 2006年7月26日 水曜日 午前9時25分
E-13 Parts and functions (Continued) Menu operation of the unit !1LCD panel This displays the menus for items selected with the menu operation buttons !2, !5, !8, !11, !14 and !17. This is also capable of displaying the time code. !2BLACK/SHAD button This selects the large item displayed on the LCD panel. The display will switch to BLACK # SHAD # before entering into the menu mode # BLACK step by step every time the button is pressed. !3BLACK lamp This lamp is on when BLACK is selected on the LCD panel. !4SHAD lamp This lamp is on when SHAD is selected on the LCD panel. !5FLARE/MATRIX button This button selects the large item displayed on the LCD panel. The display will switch to FLARE # MATRIX # before entering into the menu mode # FLARE step by step every time the button is pressed. !6FLARE lamp This lamp is on when FLARE is selected on the LCD panel. !7MATRIX lamp This lamp is on when MATRIX is selected on the LCD panel. !8GAMMA/DTL button This selects the large item displayed on the LCD panel. The display will switch to GAMMA # DTL # before entering the menu mode # GAMMA step by step every time the button is pressed. !9GAMMA lamp This lamp is on when GAMMA is selected on the LCD panel. !10DTL lamp This lamp is on when DTL is selected on the LCD panel. !11WHITE/SKIN DTL button This selects the large item displayed on the LCD panel. The display will switch to WHITE # SKIN DTL # before entering the menu mode # WHITE step by step every time the button is pressed. !12WHITE lamp This lamp is on when WHITE is selected on the LCD panel. !13SKIN DTL lamp This lamp is on when SKIN DTL is selected in on the LCD panel. !2 !4 !1 !3 !7 !6 !10 !9 !13 !12 !16 !15 !19 !18 !5!8!11!14!17 !20 !21 AJ-RC10G.book 13 ページ 2006年7月26日 水曜日 午前9時25分
E-14 ENGLISH Parts and functions (Continued) !14KNEE/FUNC button This selects the large item displayed on the LCD panel. The display will switch to KNEE # FUNC # before entering the menu mode # KNEE step by step every time the button is pressed. !15KNEE lamp This lamp is on when the KNEE is selected on the LCD panel. !16FUNC lamp This lamp is on when the FUNC is selected on the LCD panel. !17SHUTTER/SYSTEM button This selects the large item displayed on the LCD panel. The display will switch to SHUTTER # SYSTEM # before entering the menu mode # SHUTTER step by step every time the button is pressed. !18SHUTTER lamp This lamp is on when the SHUTTER is selected on the LCD panel. !19SYSTEM lamp This lamp is on when the SYSTEM is selected on the LCD panel. !203 button !21 4 button This button switches the display on the LCD panel and selects a medium item from the menu of the unit. The lamp is on when the button is pressed and off when the button is released. !22MENU ON button To open the menu on the camera recorder, press this button continuously for 3 seconds. In this case, a message “CAMERA MENU OPEN” is displayed on the LCD panel. The lamp is on at this time, and operations of the menu and the scene file on the unit are not available. If this button is pressed when the menu of the camera recorder is open, the menu will close. !23CHARA ON button This selects whether any characters are overlaid on the video signals output from the VIDEO OUT connector of the unit. When the power is on, the unit is in the state it was before turning off the power. The lamp is on when characters are loaded onto the signals, while it is off when characters are not loaded. !24Rotary encoder 1 !25Rotary encoder 2 !26Rotary encoder 3 This is used for operating the menu on the LCD panel or the camera menu. The camera menu is operated by using the right rotary encoder. The operation of the rotary encoder is the same as the JOG switch on the camera (+, –, PUSH) !27Vacant button This is a vacant button for which no function is assigned. !22 !27 !24 !23 !25!26 AJ-RC10G.book 14 ページ 2006年7月26日 水曜日 午前9時25分
E-15 Parts and functions (Continued) Rear panel !1Camera connection connector To connect the 10-pin camera control cable. !2VIDEO OUT connector An NTSC or PAL monitor is connected for operating the menu on the main unit of the camera recorder. !3Cable length selector switch This switch is on for a 50 m cable. !4Frequency characteristics adjustment volume This adjusts the frequency characteristics of the VIDEO signals. !5Level adjustment volume This adjusts the level of the VIDEO signals. !6Covering screw The unit can be used when the four screws are removed. However, do not leave the unit without these screws for long periods of time. When the screws are not in use, they must be stored safely. Do not remove the four screws on the back panel. !2!1 VIDEO OUT CAM RCU 50m 10mCABLEFREQUENCY LEVEL !4 !3 !5 !6 1 2 3 456 7 8 910 Pin No. Signal 1CAM DATA (H) 2CAM DATA (C) 3 CAM CONT (H) 4 CAM CONT (L) 5 ECU_ON 6Video input 7 GND (Video) 8 Standby 9+12 V (IN) 10 GND AJ-RC10G.book 15 ページ 2006年7月26日 水曜日 午前9時25分
E-16 ENGLISH Basic operations When the power is on When the POWER button is pressed, the lamp for the PANEL ACTIVE button is on, and the settings of the camera recorder are read into the unit. The respective numerical values are displayed on the PRE/A/B display, CC/ND display, GAIN display, and the IRIS display, while R GAIN and B GAIN are displayed on the LCD panel. In this case, only the PANEL ACTIVE button, the SW ACTIVE button, the VR ACTIVE button, the AUTO IRIS button, M.PED volume and the IRIS volume can be operated from the unit, while other buttons and volumes are not operative. However, the settings on the A.KNEE ON button, the SHT ON button ,the AUTO IRIS button, the BAR ON/OFF button and the CHARA ON button will be in the states that had been set on the unit at the last time. To enable the buttons/volumes When the SW ACTIVE button is pressed and the lamp is on, button operations are enabled. 1) Operations of the camera part When the SW ACTIVE button is pressed, operations of the USER MAIN button, GAIN and the camera recorder such as storing scene files in the built-in memory or reading them out, are enabled. When the SW ACTIVE button is pressed again, the lamp is tuned off and button operations are inhibited, while the state of settings that have already been set previously is remained as it is. 2) Operation of the recording part When the lamp of the RECORDER ENABLE button is turned off, operations of the recording part are disabled. Turn on the lamp of the RECORDER ENABLE button by pressing the button, and then operate the buttons of “PLAY”, “FF” or “REW”. To record signals, operate the REC S/S button. 3) To display numerical values on the LCD panel The GAIN volume is displayed when the power is on. If the button operations are enabled, it is possible to switch the displayed GAIN volume # BLACK volume # a numerical value for M/ PED # TC step-by-step by using the 3button and the 4button. When volume operation is enabled, the volume level is forcibly displayed if the GAIN volume or the BLACK volume is operated. However, it is possible to return the screen to the state before operating the GAIN volume or the BLACK volume by pressing the Rotary Encoder 3. It is impossible to switch the display when the unit menu or the camera menu is operating. The volume level is not displayed even if the volume is operated. To disable buttons/volumes If the lamp of the PANEL ACTIVE button is turned off, operations using the buttons and the volume on the panel are inhibited. If the lamp of the VR ACTIVE button is turned off by pressing the button, setting the GAIN and BLACK using the volume controls is inhibited. Use this feature if you intend to retain the settings. However, note that if the volume is moved when inhibited, the volume level change will be reflected immediately after turning on the lamp of the PANEL ACTIVE button and/or the VR ACTICE button by pressing the button again. It is possible for the GAIN and the BLACK to avoid changes in the volume position during the inhibition by setting the volume mode on the unit menu to a relative value (REL). AJ-RC10G.book 16 ページ 2006年7月26日 水曜日 午前9時25分
E-17 Basic operations (Continued) Operation of the camera recorder 1) Operation of the display interlocking switch Select the white balance settings by using the PRE/A/B button and monitoring the PRE/A/B display. The state of the camera recorder filter is displayed on the CC/ND display. If two filters are installed on the camera recorder, it is impossible to switch the filters from the unit but it is possible to switch the display by using the FILTER ND/CC button. The ND filter is indicated with numerical values while the CC filter is indicated with letters of the alphabet. The gain will change when using the two buttons of the M.GAIN 3 button and M.GAIN4 button and monitoring the GAIN display. However, if super gain is set to ON in the USER switch, operations of the MGAIN button are disabled. 2) Operation of the USER switch The USER MAIN/USER1/USER2 switch functions the same as the USER switch on the camera recorder. Functions of the USER switch can be set and confirmed on the camera menu or the USER-SW item on the unit menu. 3) Operation of the ABB/AWB/BAR switch The ABB button and the AWB button function the same as the switch for the white balance/ black balance of the camera recorder. The lamp is on when the unit is operated. If the button is pressed again during operation, the lamp will flash for 5 seconds to indicate an interruption of the operation. If “PRE” is selected in the PRE/A/B selection of the white balance, it is impossible to change the setting, and the lamp will flash for 5 seconds. The BAR button switches the camera output to the color bar. The lamp is on when the camera output outputs the color bar. 4) Operation of other switches For the MATRIX ON button, the DTL OFF button, A.KNEE ON button, HIGH COLOR ON button, and the SHT ON button, the ON and OFF states switch every time the button is pressed. The lamp for the DTL OFF button is on when the button is OFF. The lamps for the other buttons are on when the button is on. AJ-RC10G.book 17 ページ 2006年7月26日 水曜日 午前9時25分
E-18 ENGLISH Basic operation (Continued) Operation of the camera using the unit volume When the lamp of the PANEL ACTIVE button is on, operations of the M.PED volume and the IRIS volume are enabled. When the lamp of the AUTO IRIS button is on, the IRIS volume functions as the volume for setting the target value of the auto iris. When the lamp of the VR ACTIVE button is on, operations of the GAIN volume and the BLACK volume are enabled. In the unit menu, it is possible to select whether the GAIN volume and the BLACK volume are operated in the absolute value mode or the relative value mode. zIn the relative value mode, the value will not change when the volume operation is enabled, but it will change by the amount that the volume turned from the position when the volume operation was enabled. In the absolute value mode, the value will be fixed according to the position of the volume when the volume operation was enabled, and the value for the center click is 0. zA variable range for the volume can be selected as follows. However, the GAIN setting range covers variations within n200, and the BLACK setting range covers variations within n100, respectively. 1) GAIN volume When the white balance is set using the PRE/ A/B button and the auto white balance (AWB) executes, the lamp of the VR ACTIVE button turns off, and the volume operation is disabled. When executing the AWB, the GAIN set value will be “0” if the AWB OFFSET is set to OFF, while the GAIN set value is retained if the AWB OFFSET is set to ON. When the relative value mode and the absolute value mode are switched, the lamp of the VR ACTIVE button turns off and the volume operation is disabled. (The GAIN value is unchanged.) 2) BLACK volume This functions as an adjustment volume for the flare (FLR) or the pedestal (PED) selected in the BLACK-VR-CONTROL on the unit menu. If the auto black balance (ABB) is executed while the pedestal is selected, the lamp of the VR ACTIVE button turns off, and the volume operation is disabled. In this case, if the PEDESTAL OFFSET of the camera recorder is set to OFF, the set value will be cleared to 0. When the BLACK-VR-CONTROL item in the unit menu changes, the lamp of the VR ACTIVE button turns off, and the volume operation is disabled. If the BLACK-VR-CONTROL is set to “PED”, the flare value can be changed in the unit menu but it is impossible to change the pedestal value. Volume variable range MIN NORMAL MAX GAIN100 200 400 BLACK50 100 200 Changes in the VR ACTIVE button when the ABB is executed VR settingBLACK-VR- CONTROLPEDESTAL OFFSET OFF ON REL (relative value)PEDTurned off (disabled)Turned off (disabled) FLRRetains stateRetains state ABS (absolute value)PEDTurned off (disabled)Turned off (disabled) FLRRetains stateRetains state Changes in the volume set value when the ABB is executed VR settingBLACK-VR- CONTROLPEDESTAL OFFSET OFF ON REL (relative value)PED Cleared to 0 Retains FLR Retains Retains ABS (absolute value)PED Cleared to 0 Retains FLR Retains Retains AJ-RC10G.book 18 ページ 2006年7月26日 水曜日 午前9時25分
E-19 Basic operation (Continued) 3) M.PED volume When the volume operation is enabled, the unit operates in the absolute value mode where the value is fixed in accordance with the position of the volume. The value will be “0” by clicking the center. The variable amount is within a range between the minimum value of –200 and the maximum value of +200 with the center value of 0.Operation of the scene file The unit has five sets of scene files and is capable to storing the current settings as a scene file or loading the stored settings. It is also possible to store/call scene files using the SD memory card. For details, refer to “Saving/Loading of scene files onto the SD memory card” (page 21). 1) Operation of the scene file When the lamp of the RECORDER ENABLE button is off, the scene files are operated using the seven buttons on the top right side of the unit. Storing:Select a file number to store using buttons 1 to 5 (blue letters). When the button is pressed, the button lamp will flash. If the SAVE (blue letters) button is pressed in this state, the SAVE button lamp will also flash. To store the file, press the SAVE button again. When the store operation is finished, the lamp of the button for the stored file number turns on. When the lamps for buttons 1 to 5 are flashing, press the button or leave for 10 seconds or more to release the selection. Loading:Select a file number to load using buttons 1 to 5 (blue letters). When the button is pressed, the button lamp will flash. If the LOAD button is pressed in this state, the selected file will load. At this time, the lamp of the VR ACTIVE button flashes, the operation mode of the volume set in the unit menu is ignored, and the unit is in the relative value mode. AJ-RC10G.book 19 ページ 2006年7月26日 水曜日 午前9時25分