Page 121
Maintenance > 121 image drum cartridge. Place the cartridge on a piece of paper to avoid marking your furniture. 9. Take the new image drum cartridge out of its packaging and place it on the piece of paper where the old cartridge was placed. Keep it the same way round as the old unit. Pack the old cartridge inside the packaging material for disposal. 10. Place the toner cartridge onto the new image drum cartridge as shown. Push the left end in first, and then lower the right end in. (It is not...
Page 122
Maintenance > 122 14.Gently lower the scanner. Transfer Belt Replacement The belt unit is located under the four im age drums. This unit requires replacement approximately every 80,000 pages. 1. Switch off the MFP and allow the fuser to cool for about 10 minutes before opening the cover. 2. Pull the lever (a) firmly to release the lo ck and then gently raise the scanner (b). NOTE If you need to return or transport this product for any reason, please make sure you remove the image drum unit...
Page 123
Maintenance > 123 3.Press the cover release (a) and open the top cover (b) fully. 4. Note the positions of the four cartridges. It is essential that they go back in the same order. WARNING! If the MFP has been powered on, the fuser will be hot. This area is clearly labelled. Do not touch. 1. Cyan cartridge 3. Yellow cartridge 2. Magenta cartridge 4. Black cartridge b a 1 2 3 4 Downloaded From ManualsPrinter.com Manuals
Page 124
Maintenance > 124 5.Lift each of the image drum units out of the MFP and place them in a safe place away from direct sources of heat and light. 6. Locate the two fasteners (1) at each side of the belt and the lifting bar (b) at the front end. 7. Turn the two fasteners 90° to the left. This will release the belt from the MFP chassis. 8. Pull the lifting bar (2) upwards so that belt tilts up towards the front, and withdraw the belt unit from the MFP. CAUTION! The green image drum surface at the base...
Page 125
Maintenance > 125 9.Lower the new belt unit into place, with th e lifting bar (2) at the front and the drive gear towards the rear of the MFP. Locate the drive gear into the gear inside the printer by the rear left corner of the unit, and lower the belt unit flat inside the MFP. 10. Turn the two fasteners (1) 90° to the right un til they lock. This will secure the belt unit in place. 11. Replace the four image drums, complete with their toner cartridges, into the printer in the same sequence as...
Page 126
Maintenance > 126 Fuser Replacement The fuser is located inside the MFP just behind the four image drum units. 1. Switch off the MFP and allow the fuser to cool for about 10 minutes before opening the cover. 2. Pull the lever (a) firmly to release the lo ck and then gently raise the scanner (b). 3. Press the cover release (a) and open the top cover (b) fully. WARNING! If the MFP has recently been po wered on, some fuser components will be very hot. Handle the fuser with extreme care, holding it only...
Page 127
Maintenance > 127 4.Identify the fuser handle (1) on the top of the fuser unit. 5. Pull the fuser retaining lever (2) towards th e front of the MFP so that it is fully upright. 6. Holding the fuser by its handle (1), lift the fuser straight up and out of the MFP. If the fuser is still warm, place it on a flat surface which will not be damaged by heat. 7. Remove the new fuser from its packaging and remove the transit material. 8. Holding the new fuser by its handle, make su re that it is the correct...
Page 128
Maintenance > 128 10.Push the retaining lever (2) towards the rear of the MFP to lock the fuser in place. 11. Close the top cover and press down firm ly so that the cover latches closed. 12. Gently lower the scanner. 2 Downloaded From ManualsPrinter.com Manuals
Page 129
Maintenance > 129 Cleaning ...the Unit Casing 1.Switch off the MFP. 2. Wipe the unit surface with a soft cloth moistened sparingly with water or neutral detergent. 3. Use a soft dry cloth to dry the unit surface. 4. Tu r n o n t h e M F P. ...the ADF From time to time the pad assembly and feed rollers may become contaminated with ink, toner particles or paper dust. In this ca se the scan module may not feed documents smoothly. If this occurs, follo w the cleaning procedure below. 1. Carefully...
Page 130
Maintenance > 130 2.Moisten a soft, clean, lint-free cloth and wipe the feed rollers (3) by moving the cloth from side to side. 3. Rotate the rollers forward with your fing er and repeat step 2 until the rollers are clean. 4. Carefully lift inner cover (4). 5. Wipe rollers (5 & 6) by moving the cloth from side to side. 6. Rotate the rollers forward with your fing er and repeat step 5 until the rollers are clean. 7. Close the ADF front cover. NOTE Turn gear wheel (7) to rotate rollers (6). 23 5 4 67...