Maintenance > 101 8.Gently shake the new cartridge from end to end several times to loosen and distribute the toner evenly inside the cartridge. 9. Remove the wrapping material and peel off the adhesive tape from the underside of the cartridge. 10. Holding the cartridge by its top centre with the coloured lever to the right, lower it into the printer over the image drum unit from which the old cartridge was removed. 11. Insert the left end of the cartridge into th e top of the image drum unit...
Page 102
Maintenance > 102 14.Gently lower the scanner on to its supports. IMAGE DRUM REPLACEMENT There is no need to switch the MF P off when changing image drum(s). 1. Lift the scanner. 2. Press the cover release (a) and open the top cover of the printer (b) fully. 3. Note the positions of the 4 cartridges/image drums. WARNING! If the printer has been powered on, the fuser will be hot. This area is clearly labelled. Do not touch. 1. Cyan cartridge 3. Yellow cartridge 2. Magenta cartridge 4. Black cartridge...
Page 103
Maintenance > 103 4.Holding it by its top centre, lift the image drum, complete with its toner cartridge, up and out of the printer. 5. Put the old unit down gently onto a piec e of paper to contain any toner spillage. 6. Take the new image drum unit, complete with toner cartridge (assembled according to the installation guide) and place it on the piece of paper alongside the old ID unit. 7. Remove the protective sheets from the im age drum unit. Keep it the same way round as the old unit. Pack the...
Page 104
Maintenance > 104 8.Holding the complete assembly by its top ce ntre, lower it into place in the printer, locating the pegs at each end into their re spective slots in the sides of the printer cavity. 9. Close the printer top cover and press down firmly so that the cover latches closed. 10. Gently lower the scanner on to its supports. TRANSFER BELT REPLACEMENT The belt unit is located under the four im age drums. This unit requires replacement approximately every 50,000 pages. 1. Switch the MFP...
Page 105
Maintenance > 105 2.Lift the scanner. 3. Press the cover release (a) and open the top cover of the printer (b) fully. 4. Note the positions of the 4 cartridges. It is essential that they go back in the same order. 1. Cyan cartridge 3. Yellow cartridge 2. Magenta cartridge 4. Black cartridge < < < < a b 1 2 3 4 Downloaded From ManualsPrinter.com Manuals
Page 106
Maintenance > 106 5.Starting from the rear, lift each of the image drum units, out of the printer and place them in a safe place away from direct sources of heat and light. 6. Locate the two fasteners (a) at each side of the belt (b) and the lifting bar (c) at the front. Turn the two fasteners 90° to the le ft. This will release the belt from the printer chassis. CAUTION! The green image drum surface at the base of each cartridge is very delicate and light sensitiv e. Do not touch it and do not...
Page 107
Maintenance > 107 7.Pull the lifting bar (c) upwards so that belt tilts up towards the front, and withdraw the belt unit from the printer. 8. Lower the new belt unit into place, with th e lifting bar at the front and the drive gear towards the rear of the printer. Locate the drive gear into the gear inside the printer by the rear left corner of the unit, and lower the belt unit flat inside the printer. 9. Turn the two fasteners (a) 90° to the right un til they lock. This will secure the belt unit...
Page 108
Maintenance > 108 10.Replace the 4 image drums, complete with their toner cartridges, into the printer in the correct positions as shown. 11. Close the printer top cover and press down firmly so that the cover latches closed. 12. Gently lower the scanner on to its supports. 13. Switch the MFP ON. 1. Cyan cartridge 3. Yellow cartridge 2. Magenta cartridge 4. Black cartridge 1 2 3 4 Downloaded From ManualsPrinter.com Manuals
Page 109
Maintenance > 109 FUSER REPLACEMENT The fuser is located inside the printer just behind the four image drum units. 1. Switch the MFP OFF. 2. Lift the scanner. 3. Press the cover release (a) and open the top cover of the printer (b) fully. WARNING! If the MFP has recently been po wered on, some fuser components will be very hot. Handle the fuser with extreme care, holding it only by its handle, which will only be mildly warm to the touch. A warning label clearly indicates the area. If in doubt,...
Page 110
Maintenance > 110 4.Identify the fuser handle (1) on the top of the fuser unit. 5. Pull the two fuser retaining levers (a) toward s the front of the printer so that they are fully upright. 6. Holding the fuser by its handle (1), lift the fuser straight up and out of the printer. If the fuser is still warm, place it on a flat surface which will not be damaged by heat. 7. Remove the new fuser from its packaging and remove the transit material. 8. Holding the new fuser by its handle, make su re that...