Page 91
Maintenance > 91 8.Holding the complete assembly by its top centre, lower it into place in the printer, locating the pegs at each end into their respective slots in the sides of the printer cavity. 9. Close the printer top cover and press down firmly so that the cover latches closed. 10. Gently lower the scanner on to its supports. C,M,Y NOTE If you need to return or transp ort your printer for any reason, please make sure you remove the image drum unit beforehand and place in the ba g provided....
Page 92
Maintenance > 92 TRANSFER BELT REPLACEMENT The belt unit is located under the four image drums. This unit requires replacement approximately every 50,000 pages. 1.Switch the MFP OFF. 2. Lift the scanner. WARNING! If the printer has been powe red on, the fuser will be hot. This area is clearly labelled. Do not touch.
Page 93
Maintenance > 93 3.Press the cover release (a) and open the top cover of the printer (b) fully. 4. Note the positions of the 4 cartridges/toner cartridges. It is essential that they go back in the same order a b 1 2 3 4 1.Cyan cartridge 2.Magenta cartridge 3. Yellow cartridge 4.Black cartridge Downloaded From ManualsPrinter.com Manuals
Page 94
Maintenance > 94 5.Starting from the rear, lift each of the image drum units, out of the printer and place them in a safe place away from direct sources of heat and light. CAUTION! The green image drum surface at the base of each cartridge is very delicate and light sensitive. Do not touch it and do not expose it to normal room light for more than 5 minutes. If the drum unit needs to be out of the printer for longer th an this, please wrap the cartridge inside a black plastic bag to keep it...
Page 95
Maintenance > 95 6.Locate the two fasteners (a) at each side of the belt (b) and the lifting bar (c) at the front. Turn the two fasteners 90° to the left. This will release the belt from the printer chassis. 7. Pull the lifting bar (c) upwards so that belt tilts up towards the front, and withdraw the belt unit from the printer. a a b c Downloaded From ManualsPrinter.com Manuals
Page 96
Maintenance > 96 8.Lower the new belt unit into place, with the lifting bar at the front and the drive gear towards the rear of the printer. Locate the drive gear into the gear inside the printer by the rear left corner of the unit, and lower the belt unit flat inside the printer. 9. Turn the two fasteners (a) 90° to the right until they lock. This will secure the belt unit in place. a a Downloaded From ManualsPrinter.com Manuals
Page 97
Maintenance > 97 10.Replace the 4 image drums, complete with their toner cartridges, into the printer in the correct positions as shown. 5. Close the printer top cover and press down firmly so that the cover latches closed. 6. Gently lower the scanner on to its supports. 7. Switch the MFP ON. 1. Cyan cartridge 2.Magenta cartridge 3. Yellow cartridge 4.Black cartridge 1 2 3 4 Downloaded From ManualsPrinter.com Manuals
Page 98
Maintenance > 98 FUSER REPLACEMENT The fuser is located inside the printer just behind the four image drum units. 1.Switch the MFP OFF. 2. Lift the scanner. WARNING! If the MFP has recently been powered on, some fuser components will be very ho t. Handle the fuser with extreme care, holding it only by its handle, which will only be mildly warm to the touch. A warning label clearly indicates the area. If in doubt, switch the printer off and wait at leas t 10 minutes for the fuser to cool before...
Page 99
Maintenance > 99 3.Press the cover release and open the printer’s top cover fully. 4. Identify the fuser handle (1) on the top of the fuser unit. 5. Pull the two fuser retaining levers (a) towards the front of the printer so that they are fully upright. 6. Holding the fuser by its handle (1), lift the fuser straight up and out of the printer. If the fuser is still warm, place it on a flat surface which will not be damaged by heat. a b a a 1 Downloaded From ManualsPrinter.com Manuals
Page 100
Maintenance > 100 7.Remove the new fuser from its packaging and remove the transit material. 8. Holding the new fuser by its handle, make sure that it is the correct way round. The retaining levers (2) should be fully upright, and the locating lugs (3) should be towards you. There is one locating lug at each end of the fuser. 9. Holding the fuser by its handle , lower it into the printer, locating the two lugs into their slots in the metal partition which separates the fuser area from the image...