Page 51
Installation / 45 P0992639 01 Modular ICS Companion Installer Guide Installing an outdoor omni-directional external antenna (Canada) When installing an outdoor omni-directional external antenna: Locate the antenna on the external wall of the building. Note: The antenna must be mounted on a vertical surface. Keep the outdoor omni-directional external antenna as close as possible to the base station serving it. The base station itself must be indoors. The recommended mounting height is 4 m to 5 m...
Page 52
46 / Installation Modular ICS Companion Installer Guide P0992639 01 Installing the outdoor omni-directional external antenna (Canada) To install an outdoor omni-directional external antenna, follow these steps: 1. Screw the antenna mounting plate vertically to the exterior wall of the building with lag bolts or other appropriate hardware as shown in the illustration, Installing the outdoor omni-directional external antenna (Canada). 2. Feed one end of the co-axial cable up through the bottom of the...
Page 53
Installation / 47 P0992639 01 Modular ICS Companion Installer Guide 4. Rotate the mast until the threaded hole in the base of the mast is aligned with the set screw hole in the shroud, and then tighten the set screw. 5. Route the co-axial cable along the bottom edge of the plate between the shroud and the wall plate and tie the cable up. Note: The total length of the co-axial cables from the outdoor external antenna to the base station must not exceed 10 m. 6. Insert the plastic plug into the base...
Page 54
48 / Installation Modular ICS Companion Installer Guide P0992639 01 Installing the lightning surge protector (Canada) 2. Before you connect the ground lead to the surge protector, attach it to an approved ground. The recommended wire gauge is 6 AWG (4 mm). Connect the ground lead to the building ground. Do not connect to a ground rod or series of ground rods. If you cannot connect the ground lead to the building ground, connect it to the steel of the building. The connection should be no more than...
Page 55
P0992639 01 Modular ICS Companion Installer Guide Powering up the system If you added a base station that requires a software update, the system begins downloading the software to the base station. The Administration Terminal display shows BS-1 Dload Start. Press CLEAR to clear the message. When the base station software is downloaded, the Administration Terminal shows BS-1 Dload Done. Press CLEAR to clear the message. Some Base Stations may not be powered up at the same time, and this message...
Page 57
P0992639 01 Modular ICS Companion Installer Guide Programming Programming is performed by the installer or the customer service representative. The interface allows you to change settings for the entire Norstar system, plus settings for individual telephones and external lines. Most of the settings can also be programmed by a system coordinator who has a SysCoord+ password. This password is distributed only by the installer to avoid system complications. Installation programming Before you attempt...
Page 58
52 / Programming Modular ICS Companion Installer Guide P0992639 01 Programming tools As with all Modular ICS programming, you can use a T7316 Business Series Terminal or an M7310 or M7324 Norstar set to perform the programming. In this book, all processes requiring dialpad buttons are presented in the Business Series Terminal button icons. If you are using one of the other telephones, use the appropriate overlay, and then refer to the table below for corresponding button faces: Programming overlays...
Page 59
Programming / 53 P0992639 01 Modular ICS Companion Installer Guide When you have completed your programming session, press ¨. The display briefly reads End of session. Viewing your programming updates If any of the changes you have made to programming have not immediately taken effect, you see an UPDATE display button when you leave programming. The display shows you how many telephones have not been currently updated due to the system being busy with other programming or the telephone is in use....
Page 60
54 / Programming Modular ICS Companion Installer Guide P0992639 01 Passwords defaults Reg. pswd72346 (RADIO) System programming Registration Registration Portable DNs N Availble Radio data Re-evaluation Status Schedule Radio credits (U.S. only) Required Not scheduled No defaults assigned Radios Cell Assignment Antenna Type Unassigned Internal Cells Cell radios Cell nghbrs Cell rad nghbrs Unassigned Unassigned Unassigned Note: DID Companion defaults are the same as PBX defaults. SettingDefault