Home > Nortel > Communications System > Nortel Modular Ics 6.0 Programming Record Manual

Nortel Modular Ics 6.0 Programming Record Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Nortel Modular Ics 6.0 Programming Record Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 211 Nortel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							63
    P0992642 03 Modular ICS 6.0 Programming Record
    Hardware
    Cards on KSU
    (Profiles 1 and 4 only)
    (Profiles 2 and 3 only)
    If card is a Loop card
    If card is a T1 card
    Cd1-KSULoop   T1 PRI BRI-ST BRI-U2 BRI-U4
    Cd2-KSULoop
       T1 PRI BRI-ST BRI-U2 BRI-U4
    Cd1-KSULoop
       T1 BRI-2 BRI-ST
    Cd2-KSULoop
       T1 BRI-2 BRI-ST
    Card typeLoop
    Lines
    Discon timer60
    100 260 460 600
    Card typeT1
    Lines
    Discon timer60
    100 260 460 600
    Answer timer1
    2345
    CO failTR62411
    T1A-547A
    I/F levelsISDN
    PSTN
    FramingSF
    ESF
    Internal CSUOn
    Off
    CSU line bld
    (If CSU is on)0
    7.5 15
    DSX1 bld
    (If CSU is off)000-100
    100-200 200-300 300-400
    400-500 500-600 600-700
    Line codingB8ZS
    AMI
    Clock Src
    (default for Cd1-KSU is 
    Primary,Cd2-KSU is 
    Secndry)Primary
    Secndry TimeMst 
    						
    							64
    Modular ICS 6.0 Programming RecordP0992642 03
    If card is a PRI card
    (Profiles 1 and 4 only)
    Card type PRI
    Lines
    Protocol
       
     protcl
    (Not shown if only one 
    protocol available)NI-2
    DMS100 DMS250 4ESS SL-1 (does not show unless MCDN is active)
    PrivNetID
    range: 1-12730
    BchanSeq
    (Default is Descend 
    unless SL-1 Master)AscendDescend
    CbC Routing
    FX
    (Only shown for: NI-2, 
    DMS-100, and 
    DMS-250)None
    All Map table
    800
    (Only shown for: NI-2, 
    DMS-100, DMS-250, 
    and 4ESS)None
    All Map table
    I800
    (Only shown for: 
    4ESS)None
    All Map table
    900
    (Only shown for: 
    DMS-250, and 4ESS)None
    All Map table
    SDS
    (Only shown for: 
    4ESS)Non
    eAll Map table
    Type
    (User prompt only 
    shown when Procol is 
    SL-1) Secondary
    Primary User
    CO failTIA547A
    TR62411
    I/F levelsISDN
    PSTN                 ISD/TT
    FramingESF
    SF
    Internal CSUOn
    Off
    CSU line bld0
    7.5 15
    Line codingB8ZS
               AMI   
    ClockSrcPrimary
    Secndry TimMstr 
    						
    							65
    P0992642 03 Modular ICS 6.0 Programming Record
    If card is an ETSI PRI card
    (Profile 2 only)
    If card is a DID card 
    (Profiles 1, 3, and 4 only)
    If card is an E&M card
    If card is a BRI-U2, BRI-U4 or BRI-ST card 
     
    (for Profiles 1 and 4 only)
    For S & LT only 
    (for Profiles 1 and  4 only)Card type PRI
    Lines
    ProtocolEURO
    SL1 (does not show unless MCDN is active)
    PrivNetID
    range: 1-1271 (does not show unless MCDN is active)
    BchanSeq
    (Default is Descend 
    unless SL-1 Master)AscendDescend (does not show unless MCDN is active)
    Type
    (Procol is SL-1) SlavePrimary User (does not show unless MCDN is active)
    ClockSrcPrimarySecndry TimMstr
    Max Transits31
     (does not show unless MCDN is active)
    Ovlp recvingN2
    Card type DID
    Lines
    Card typeE&M
    Lines
    Answer timer1
    2345
    Card type BRI-_____
    Loops
    Loop Type
       Type
        (If BRI-U2 or BRI-U4
         default is NT) T
    SLT NT 
    Protocol
    (Not shown if only one 
    protocol available)
    Sampling
    (Shown for S loop type 
    only) Adaptve 
    Fixed 
    Assign DNs
     Show DN:__Assigned
     Availabl *LP___* LP___
    Loop DN:_NoneISDN DN 
    						
    							66
    Modular ICS 6.0 Programming RecordP0992642 03
    For T & NT only 
    (for Profiles 1 and  4 only)
    If card is a BRI-2 or BRI-ST card
    (for Profiles 2 and  3 only)SPID__
    # of B-channls1
    2
    Network DNs
       DN1:
         Call typeVoice
    Data Both
       DN2:
         Call typeVoice
    Data Both
       DN3:
         Call typeVoice
    Data Both
       DN4:
         Call typeVoice
    Data Both
       DN5:
         Call typeVoice
    Data Both
       DN6:
         Call typeVoice
    Data Both
       DN7:
         Call typeVoice
    Data Both
       DN8:
         Call typeVoice
    Data Both
    D-packet service
    (BRI-U2 & BRI-U4)Y
    N
         LPnnnNone
    S-Lp___ Lt-Lp___
    TEIs (0-63)
    ClockSrc
     (On core only)Primary
    Secndry TimMstr
    ONN blkSuprsBit
    SrvcCode
    Card type BRI-_____
    Loops
    Loop Type
       Type    S
    T 
    						
    							67
    P0992642 03 Modular ICS 6.0 Programming Record
    For S
    (for Profiles 2 and  3 only)
    For T
    (for Profiles 2 and  3 only)
    Modules
    (for Profile 1 only)
    Modules
    (for Profiles 2, 3 and 4 only)SamplingAdaptve 
    Fixed 
    Assign DNs
     Show DN:__Assigned
     Availabl *LP___* LP___
    Loop DN:_NoneISDN DN
    ClockSrc
     (On core only)Primary
    Secndry TimMstr
    Ovlap recvingY
    N
    Public digit length1
    23456789101112131415
    Mod 03StnMod
    ASM DataMod TrunkMod
    Mod 04StnMod
    ASM DataMod TrunkMod
    Mod 05StnMod
    ASM DataMod TrunkMod
    Mod 06StnMod
    ASM DataMod TrunkMod
    Mod 07StnMod
    ASM DataMod TrunkMod
    Mod 08StnMod
    ASM DataMod TrunkMod
    Mod 03StnMod
    ASM TrunkMod
    Mod 04StnMod
    ASM TrunkMod
    Mod 05StnMod
    ASM TrunkMod
    Mod 06StnMod
    ASM TrunkMod
    Mod 07StnMod
    ASM TrunkMod
    Mod 08StnMod
    ASM TrunkMod 
    						
    							68
    Modular ICS 6.0 Programming RecordP0992642 03
    TrunkMod
    (Profiles 1 and 4 only) (BRI cards and off-core DTI cartridges a re available on Modules 03 and 04 on midi systems, and on Modules
    07 and 08 for maxi systems.)
    (MICS-XC systems: TrunkMod cannot be configured for Modules 09-14.) 
    Cd1-Mod3 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd2-Mod3 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd3-Mod3 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd1-Mod4 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd2-Mod4 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd3-Mod4 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd1-Mod5 Loop
       E&M DID
    Cd2-Mod5 Loop
       E&M DID
    Cd3-Mod5 Loop
       E&M DID
    Cd1-Mod6 Loop
       E&M DID
    Cd2-Mod6 Loop
       E&M DID
    Cd3-Mod6 Loop
       E&M DID
    Cd1-Mod7 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd2-Mod7 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd3-Mod7 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd1-Mod8 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd2-Mod8 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI
    Cd3-Mod8 Loop
       E&M DID BRI-ST BRI-U2 BRI-U4 PRI 
    						
    							69
    P0992642 03 Modular ICS 6.0 Programming Record
    TrunkMod 
    (Profile 2 ) (BRI cards are available on Modules 03 and 04 on midi systems, and on Modules 07 and 08 for maxi systems.)
    (MICS-XC systems: TrunkMod cannot be configured for Modules 09-14.)  
    Cd1-Mod3 Loop
       E&M BRI-2 BRI-ST
    Cd2-Mod3 Loop
       E&M BRI-2 BRI-ST
    Cd3-Mod3 Loop
       E&M BRI-2 BRI-ST
    Cd1-Mod4 Loop
       E&M BRI-2 BRI-ST
    Cd2-Mod4 Loop
       E&M BRI-2 BRI-ST
    Cd3-Mod4 Loop
       E&M BRI-2 BRI-ST
    Cd1-Mod5 Loop
       E&M
    Cd2-Mod5 Loop
       E&M
    Cd3-Mod5 Loop
       E&M
    Cd1-Mod6 Loop
       E&M
    Cd2-Mod6 Loop
       E&M
    Cd3-Mod6 Loop
       E&M
    Cd1-Mod7 Loop
       E&M BRI-2 BRI-ST
    Cd2-Mod7 Loop
       E&M BRI-2 BRI-ST
    Cd3-Mod7 Loop
       E&M BRI-2 BRI-ST
    Cd1-Mod8 Loop
       E&M BRI-2 BRI-ST
    Cd2-Mod8 Loop
       E&M BRI-2 BRI-ST
    Cd3-Mod8 Loop
       E&M BRI-2 BRI-ST 
    						
    							70
    Modular ICS 6.0 Programming RecordP0992642 03
    TrunkMod 
    (Profiles 3 ) (BRI cards are available on Modules 03 and 04 on midi systems, and on Modules  07 and 08  for  maxi systems.) 
    (MICS-XC systems: TrunkMod cannot be configured for Modules 09-14.)
    StnMod
    For Station Module programming, see the Modular ICS 6.0 Installer Guide. Cd1-Mod3 Loop
       E&M DID BRI-2 BRI-ST
    Cd2-Mod3 Loop
       E&M DID BRI-2 BRI-ST
    Cd3-Mod3 Loop
       E&M DID BRI-2 BRI-ST
    Cd1-Mod4 Loop
       E&M DID BRI-2 BRI-ST
    Cd2-Mod4 Loop
       E&M DID BRI-2 BRI-ST
    Cd3-Mod4 Loop
       E&M DID BRI-2 BRI-ST
    Cd1-Mod5 Loop
       E&M
    Cd2-Mod5 Loop
       E&M
    Cd3-Mod5 Loop
       E&M
    Cd1-Mod6 Loop
       E&M
    Cd2-Mod6 Loop
       E&M
    Cd3-Mod6 Loop
       E&M
    Cd1-Mod7 Loop
       E&M DID BRI-2 BRI-ST
    Cd2-Mod7 Loop
       E&M DID BRI-2 BRI-ST
    Cd3-Mod7 Loop
       E&M DID BRI-2 BRI-ST
    Cd1-Mod8 Loop
       E&M DID BRI-2 BRI-ST
    Cd2-Mod8 Loop
       E&M DID BRI-2 BRI-ST
    Cd3-Mod8 Loop
       E&M DID BRI-2 BRI-ST 
    						
    							71
    P0992642 03 Modular ICS 6.0 Programming Record
    Maintenance
    System version 
    (Maintenance; System version)  
    System Version Port/DN Status
    SP: Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device: 
    						
    							72
    Modular ICS 6.0 Programming RecordP0992642 03
    Sys test log 
    (Maintenance; Sys test log)
    Sys Test Log
    Log item Time of log itemNumber of repetitions 
    						
    All Nortel manuals Comments (0)

    Related Manuals for Nortel Modular Ics 6.0 Programming Record Manual