Installation Manual • • • KSU Installation Page 47A6-506000-642-01 DPH-B13 ETU The Door Phone (DPH) ETU provides connection for two Door Phone units and two Door Lock Release devices. Use only the NEC DP-D-1D Door Phone Unit. A suitable third-party door lock release device must be locally supplied. One DPH-B13 ETU can be installed in the system. To install the DPH-B13 ETU: 1. Ensure that the system is turned OFF. 2. Remove the cover from the KSU. 3. Carefully remove the ETU from its packaging, using...
Page 62
Page 48KSU Installation • • • Installation Manual A6-506000-642-01 Door Phones Switches SW1, SW2 and RV1 allow the volume levels between the doorphone units and the KSU to be adjusted. Adjust these switches as required to achieve optimal door phone performance. (Refer to Table 2-2: DPH-B13 ETU Switch Settings, Pg 48.) Table 2-2 DPH-B13 ETU Switch Settings When the Door Phone button is pressed, one of two tones is produced at the assigned telephones (ports 01 and 02 as default). Connections: Wiring...
Page 63
Installation Manual • • • KSU Installation Page 49A6-506000-642-01 Door Lock Release While on a Door Phone call, the telephone user can enter an Access Code to operate the associated Door Lock Release momentarily so that the caller can enter the door. Connections Connection between terminals DPR1, DPR2 and the door lock device is via a single pair cable, not polarity sensitive. A dry contact closure is provided to the external device. Connection of door lock release equipment must be via a Line...
Page 64
Page 50KSU Installation • • • Installation Manual A6-506000-642-01 1. If the incoming trunk receiving volume is too low, change the G11/G12 switch setting to one level higher. 2. If the transfer destination trunk receiving volume is too low, change the G21/G22 switch setting to one level higher. 3. If the incoming trunk receiving signal contains a ‘booming’ noise, change the G11/G12 switch setting to one level lower. 4. If the transfer destination trunk receiving signal contains a ‘booming’ noise,...
Page 65
Installation Manual • • • KSU Installation Page 51A6-506000-642-01 Power Failure Backup Operation in the Event of a Power Failure In the event of a power failure, the optional built-in batteries or external batteries (locally provided) provide full backup of the service of the system for a period dependent on the system configuration and service conditions. Two Power Fail Transfer (PFT) Single Line telephone Interface Circuit are built into the KSU. The KSU connects each Single Line Telephone...
Page 66
Page 52KSU Installation • • • Installation Manual A6-506000-642-01 Operation When Input Power is Restored When input power is restored, the system automatically resets and restores service. Single Line Telephone for Power Fail Transfer A Single Line telephone can be used as a Power Fail Transfer telephone. (Refer to Power Fail telephone and Fax connection for details.) Operating Procedure To use the Single Line telephone for power fail transfer during a power failure, proceed as follows:...
Page 67
Installation Manual • • • KSU Installation Page 53A6-506000-642-01 Terminating Cables to Special Connectors When installing a B614-B13, KSU, ESI(8)-B13 ETU, COI(2)-B13 ETU, DPH-B13 ETU or SLI(2)-B13 ETU, the cables must be terminated to the connectors provided in the KTU packing box. The following instructions explain this procedure. 1. Cut the two cables the same length and insert them into the connector. Ensure that each cable has been inserted all the way tot he end of the cover. (Refer to Figure...
Page 68
Page 54KSU Installation • • • Installation Manual A6-506000-642-01 Wiring to the KSU Multiline Telephone Connection When connecting Multiline Terminals to the MDF, individually twisted 1-pair cabling must be used. (Refer to Figure 2-41:: Multiline Terminal and SLT Adapter Connection, Pg 54.) !Note:Polarity is not critical as the Multiline Terminals are not polarity conscious. Figure 2-41: Multiline Terminal and SLT Adapter Connection Single Line Telephone Connection DTMF or DP dialling and Single...
Page 69
Installation Manual • • • KSU Installation Page 55A6-506000-642-01 KSU Cable Routing All cabling should exit the KSU through the knockout panels on the right hand side. Two knockout panels are provided. Figure 2-43: KSU Cabling Knockouts Remove one or both of these knockouts as required, using side cutters or other suitable tool, to cut the tabs at the top of the knockout. Once the top is free, move the knockout back and forth until the tab at the bottom breaks free. Remove any burrs using a sharp...
Page 70
This page is intentionally blank. Page 56KSU Installation • • • Installation Manual A6-506000-642-01