Page 21
Installation Manual • • • System Overview Page 11A6-506000-642-01 SECTION 5 SYSTEM BLOCK DIAGRAM Figure Figure 1-2: NEC Xen Alpha System Block Diagram, Pg 11 represents an installed system. This diagram shows the ETUs that can be installed in the KSU and the number of channels that are supported when the ETU is installed. Figure 1-2: NEC Xen Alpha System Block Diagram
Page 22
Page 12System Overview • • • Installation Manual A6-506000-642-01 SECTION 6 REQUIREMENTS & S PECIFICATIONS This section provides cabling requirements and specifications for various equipment used in the Xen Alpha system. ! BRT(1)-B13 ETU ! COI(2)-B13 ETU ! DPH-B13 ETU ! ESI(8)-B13 ETU ! SLI(2)-B13 ETU The KSU is connected with each of the Multiline Telephones and Single Line Telephones by a separate twisted 1-pair cable or 2-pair cable (only for Multiline Telephones). (Refer to Table 1-1:: Multiline...
Page 23
Installation Manual • • • System Overview Page 13A6-506000-642-01 Table 1-2: Cable Connection Between the Analogue Port Adapter and the Single Line Telephone !Note 1:Mixing digital and analogue ports through the same 25-pair cable runs is not recommended. Note 2:The Maximum Loop Resistance includes the internal resistance of the SLT device. SECTION 7 POWER REQUIREMENTS Power Supply Inputs The AC input requirements for the Xen Alpha system are listed below: AC Input !250 Vac + 10/-15 % !50 Hz ± 10%...
Page 24
Page 14System Overview • • • Installation Manual A6-506000-642-01 SECTION 8 ENVIRONMENTAL CONDITIONS Table 1-4:: Weights and Dimensions, Pg 15 shows shipping weight, height, width, and depth of each InfoSet KSU, Multiline Telephone, and adapter. Table 1-4: Weights and Dimensions * Shipping weight includes the shipping carton. UnitShipping Weight*HeightWidthDepth ACA-UA Unit638 g 86 mm 107 mm 133 mm ADA-UA Unit65 g 29 mm 59 mm 99 mm APR-UA Unit122 g 66 mm 59 mm 121 mm B614-B13 KSU6500 g 320 mm 385...
Page 25
Installation Manual • • • System Overview Page 15A6-506000-642-01 SECTION 9 OUTSIDE LINE TYPE The following outside line types can be used with the InfoSet system. !2-wire, Loop Start Trunks !ISDN-BRI Trunks SECTION 10 NETWORK & C ONTROL Transmission, Network & Control Specifications Transmission • Data Length From Multiline Telephone to ESI(8)-B13 ETU: 23 bits From ESI(3)-B13 ETU to Multiline Telephone: 23 bits • Data Transmission Rates: Between ESI(3)-B13 ETU and Multiline Telephone: 184K bps...
Page 26
Page 16System Overview • • • Installation Manual A6-506000-642-01 Telephone The voltage, current, ring signal information for the InfoSet multiline telephones, single line telephone equipment, and APR units are listed below. • Multiline Telephone Voltage: -11 -26 Vdc Maximum Current: 250 mA • Single Line Telephone Standard 2500 Set: 500 type network Nominal Current: 35 mA Ring Signal: 56 Vac RMS @ 20 Hz • SLT(1)-U13 ADP Standard 2500 Set: 500 type network Nominal Current: 30 mA Ring Signal:...
Page 27
Installation Manual • • • System Overview Page 17A6-506000-642-01 !Rise Time: Within 5 ms !Duration of Dual Frequency Signal: • 110 ms default/60 ms. minimum !Inter-digital Time: 80 ms default/70 ms minimum SECTION 12 EXTERNAL EQUIPMENT CONNECTION Music Sources for Music on Hold via KSU !Auxiliary Input: 0.6V PPS Signal Level !Input Impedance: 600 W Music Source for Station Background Music via KSU !Auxiliary Input: 0.6V PPS Signal Level !Input Impedance: 6 00 W External Paging (Audio) via KSU...
Page 28
Page 18System Overview • • • Installation Manual A6-506000-642-01 SECTION 13 BATTERY BACKUPThe Xen Alpha system has battery backup functions for system backup and for memory backup. System Backup During a mains power failure, the system’s operation can be backup up using rechargeable batteries. The internally mounted backup batteries can support all system operations for approximately 30 minutes under average conditions. If longer backup duration’s are required, larger externally mounted batteries...
Page 29
Installation Manual • • • System Overview Page 19A6-506000-642-01 SECTION 14 VISUAL & A UDIBLE INDICATIONS Tone Patterns Table Table 1-6: Tone Patterns System Tone (Fixed)Frequency (Hz) (Fixed)ModulationCycle Automatic Callback 500 Hz (I) 540 Hz (D)N/A Barge-In Tone 440 Hz N/A Busy Tone 480 Hz 620 HzN/A Call Waiting Tone 440 Hz N/A CO/PBX Ring Tone AHigh: 1024 Hz/1285 Hz (I) 1100 Hz/1400 Hz (E) Low: 480 Hz/606 Hz (I) 520 Hz/660 Hz (E)16 CO/PBX Ring Tone BHigh: 1024 Hz/1285 Hz (I) 1100 Hz/1400 Hz (E)...
Page 30
Page 20System Overview • • • Installation Manual A6-506000-642-01 Doorphone 2Chime ToneN/A N/A Busy Chime Tone1024 Hz (I) 1100 Hz (E)N/A Hold Alarm 1024 Hz (I) 1100 Hz (E)N/A Howler Tone 2400 Hz (I & E)16 100% AM Incoming Dial Tone 360 Hz/440 Hz (I & E)N/A Incoming Ring Transfer 480 Hz/606 Hz (I) 520 Hz/660 Hz (E)16 Internal Ring Tone 500 Hz (I) 540 Hz (E)N/A Key Tone 1100 Hz (I & E) N/A Recall Tone 1024 Hz (I & E) N/A Reorder Tone 480/620 Hz N/A Ringback Tone for External Speaker CO/ PBX Ring...