Page 51
CHAPTER 3 NDA-24318 Page 44 Issue 1 OFFICE DATA PROGRAMMING This figure represent example data when ASPC and AETH commands are required for an identical FPC at the tandem node. Figure 3-17 FCCS Networking via IP [F-36] and FCH FCCS Networking (both ASPC and AETH commands) Example Data Sheet 3 Note: Provided that both FCCS Networking via IP and FCH FCCS Networking are configured, it depends on the setting of the P_ROUTE parameter, which routing takes precedence. To take priority for FCCS Networking via...
Page 52
NDA-24318 CHAPTER 3 Page 45 Issue 1 OFFICE DATA PROGRAMMING This figure represent example data when FCCS routing data is not assigned by using the AFPC command. Be sure to assign the following dummy data when using this configuration. Figure 3-18 FCCS Networking via IP [F-36] - FCCS Network via IP Tandem Connection (AFPC Dummy Data) Example Data Sheet 4 Note: Be sure to assign dummy data. PO WERRouter NEAX2400 IPX FPC 2 IPTRKTa n de m N o de C_RT: 150 IP Address: 10.40.222.20 FCHN: 20 PO WE...
Page 53
CHAPTER 3 NDA-24318 Page 46 Issue 1 OFFICE DATA PROGRAMMING This figure represent example data when AFPC and AETH commands are required for an identical FPC at the tandem node. Figure 3-19 FCCS Networking via IP [F-36] and FCH FCCS Networking (AFPC or AETH commands) Example Data Sheet 5 Note: Be sure to assign dummy data. PO WERRouter IPTRK FCH DTI C_RT: 70 FCHN: 3 C_RT: 150 IP Address: 10.40.222.20 FCHN: 20 NEAX2400 IPX FPC 2 Ta n de m N o de Intranet PO WE RRouter NEAX2400 IPX FPC 1 IPTRK...
Page 54
NDA-24318 CHAPTER 4 Page 47 Issue 1 OPERATION TESTS AFTER INSTALLATION CHAPTER 4 OPERATION TESTS AFTER INSTALLATION 1. GENERAL This chapter explains the procedure to verify the normal operation of the IPTRK circuit card, when installation and necessary data setting have been completed. This chapter also explains the procedures to test and correct possible IPTRK circuit card-related faults. 2. CCIS NETWORKING VIA IP [C-163]/VOICE OVER IP (H.323) When using the H.323 Handler (PA-8IPTB-A) as a signaling...
Page 55
CHAPTER 4 NDA-24318 Page 48 Issue 1 OPERATION TESTS AFTER INSTALLATION 1. Test of IP-LINK lamp on IPTRK circuit card: Note Note: H.323 Handler (PA-8IPTB-A). a.) See if the IP-LINK lamp on the IPTRK circuit card Note is lighting green. This lamp will light if the circuit card is physically connected to the IP network. Note:H.323 Handler (PA-8IPTB-A). b.) When the IP-LINK lamp is OFF, make sure that the Ethernet cable is securely connected to the IPCON connector. Make sure that neither the Ethernet cable...
Page 56
NDA-24318 CHAPTER 4 Page 49 Issue 1 OPERATION TESTS AFTER INSTALLATION 3. FCCS NETWORKING VIA IP [F-36] When using the IPTRK circuit card for FCCS Networking via IP [F-36] (Point-to- Multipoint Connection), perform the following circuit card operation tests. If necessary, perform fault repairs. Caution:Some LSIs on this circuit card may be hot. Handle with care. 1. Test of OPE lamp on IPTRK circuit card: a.) See if the OPE lamp on the IPTRK circuit card is lighting green. This lamp will light if the...
Page 57
CHAPTER 4 NDA-24318 Page 50 Issue 1 OPERATION TESTS AFTER INSTALLATION 3. Test of IP-LINK lamp on IPTRK circuit card: a.) See if the IP-LINK lamp on the IPTRK circuit card is lighting green. This lamp will light if the circuit card is physically connected to the IP network. b.) When the IP-LINK lamp is OFF, make sure that the Ethernet cable is securely connected to the IPCON connector. Make sure that neither the Ethernet cable nor the router are faulty. If necessary, replace the Ethernet cable. 4. Test...