    							CHAPTER 3 NDA-24318
    Page 44
    Issue 1
    OFFICE DATA PROGRAMMING
    This figure represent example data when ASPC and AETH commands are required for an identical FPC
    at the tandem node.
    Figure 3-17   FCCS Networking via IP [F-36] and FCH FCCS Networking (both ASPC and AETH commands) 
    Example Data Sheet 3
    Note:
    Provided that both FCCS Networking via IP and FCH FCCS Networking are configured, it depends on the
    setting of the P_ROUTE parameter, which routing takes precedence. To take priority for FCCS
    Networking via IP routing, assign data “1” to the P_ROUTE parameter.
    NEAX2400 IPX
      FPC 1
     
    POWERRouter
       Intranet
     
     IPTRK
     FCH
     DTI
    C_RT: 50
    FCHN: 1
    NEAX2400 IPX
      FPC 2
    PO WE RRouter IPTRK
     FCH
     DTI
    C_RT: 70
    FCHN: 3 FCH
     DTI
    C_RT: 60
    FCHN: 2
    T
    an
    d
    em
     
    No
    d
    e
    NEAX2400 IPX
      FPC 3
    PO WE RRouter IPTRK
     FCH
     DTI
    C_RT: 80
    FCHN: 4
    C_RT: 200
    IP Address: 10.40.223.20
    FCHN: 30
    Example Routing Information Assignment by AFPC and AETH:
    AFPC:
    FPC 1: FPC=2, FCCH=1, P_ROUTE=0/1, C_RT=50, FCHN=1
    FPC=3, FCCH=1, P_ROUTE=0/1, C_RT=50, FCHN=1
    FPC 2: FPC=1, FCCH=1, P_ROUTE=0/1, C_RT=60, FCHN=2
    FPC=3, FCCH=1, P_ROUTE=0/1, C_RT=70, FCHN=3
    FPC 3: FPC=1, FCCH=1, P_ROUTE=0/1, C_RT=80, FCHN=4
    FPC=2, FCCH=1, P_ROUTE=0/1, C_RT=80, FCHN=4
    AETH:
    FPC 1: FPC=2, FCHN=10, C_RT=100, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20
    FPC=3, FCHN=10, C_RT=100, DST_IP=10.40.223.20, NEXT_IP=10.40.223.20
    FPC 2: FPC=1, FCHN=20, C_RT=150, DST_IP=10.40.221.20, NEXT_IP=10.40.221.20
    FPC=3, FCHN=20, C_RT=150, DST_IP=10.40.223.20, NEXT_IP=10.40.223.20
    FPC 3: FPC=1, FCHN=30, C_RT=200, DST_IP=10.40.221.20, NEXT_IP=10.40.221.20
    FPC=2, FCHN=30, C_RT=200, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20C_RT: 100
    IP Address: 10.40.221.20
    FCHN: 10C_RT: 150
    IP Address: 10.40.222.20
    FCHN: 20 
    						
    							NDA-24318 CHAPTER 3
    Page 45
    Issue 1
    OFFICE DATA PROGRAMMING
    This figure represent example data when FCCS routing data is not assigned by using the AFPC
    command. Be sure to assign the following dummy data when using this configuration.
    Figure 3-18   FCCS Networking via IP [F-36] - FCCS Network via IP Tandem Connection
    (AFPC Dummy Data) Example Data Sheet 4
    Note:
    Be sure to assign dummy data.
    PO WERRouter
    NEAX2400 IPX
      FPC 2
     
     IPTRKTa
    n
    de
    m
     N
    o
    de
    C_RT: 150
    IP Address: 10.40.222.20
    FCHN: 20
    PO WE RRouter IPTRK
    C_RT: 151
    IP Address: 10.40.222.21
    FCHN: 21
    Use different FCHN for passing through the node
      Intranet
    NEAX2400 IPX
      FPC 1
    POWERRouter
    NEAX2400 IPX
      FPC 3
    PO WERRouter IPTRK 
     IPTRK
    C_RT: 100
    IP Address: 10.40.221.20
    FCHN: 10C_RT: 200
    IP Address: 10.40.223.20
    FCHN: 30
    Example Routing Information Assignment by AFPC and AETH:
    AFPC:
    FPC 1: None
    FPC 2:FPC=1, FCCH=1, P_ROUTE=1, C_RT=150, FCHN=20 
    NoteFPC=3, FCCH=1, P_ROUTE=1, C_RT=151, FCHN=21 Note
    FPC 3: None
    AETH:
    FPC 1: FPC=2, FCHN=10, C_RT=100, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20
    FPC=3, FCHN=10, C_RT=100, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20
    FPC 2: FPC=1, FCHN=20, C_RT=150, DST_IP=10.40.221.20, NEXT_IP=10.40.221.20
    FPC=3, FCHN=21, C_RT=151, DST_IP=10.40.223.20, NEXT_IP=10.40.223.20
    FPC 3: FPC=1, FCHN=30, C_RT=200, DST_IP=10.40.222.21, NEXT_IP=10.40.222.21
    FPC=2, FCHN=30, C_RT=200, DST_IP=10.40.222.21, NEXT_IP=10.40.222.21 
    						
    							CHAPTER 3 NDA-24318
    Page 46
    Issue 1
    OFFICE DATA PROGRAMMING
    This figure represent example data when AFPC and AETH commands are required for an identical FPC
    at the tandem node.
    Figure 3-19   FCCS Networking via IP [F-36] and FCH FCCS Networking (AFPC or AETH commands)
    Example Data Sheet 5
    Note:
    Be sure to assign dummy data.
    PO WERRouter IPTRK
     FCH
     DTI
    C_RT: 70
    FCHN: 3
    C_RT: 150
    IP Address: 10.40.222.20
    FCHN: 20 NEAX2400 IPX
      FPC 2
    Ta
    n
    de
    m 
    N
    o
    de
       Intranet
    PO WE RRouter
    NEAX2400 IPX
      FPC 1
     IPTRK
    C_RT: 100
    IP Address: 10.40.221.20
    FCHN: 10
    NEAX2400 IPX
      FPC 3
     FCH
     DTI
    C_RT: 80
    FCHN: 4
    Example Routing Information Assignment by AFPC and AETH:
    AFPC:
    FPC 1: None
    FPC 2:FPC=1, FCCH=1, P_ROUTE=1, C_RT=150, FCHN=20 
    NoteFPC=3, FCCH=1, P_ROUTE=0, C_RT=70, FCHN=3
    FPC 3: FPC=1, FCCH=1, P_ROUTE=0, C_RT=80, FCHN=4
    FPC=2, FCCH=1, P_ROUTET=0, C_RT=80, FCHN=4
    AETH:
    FPC 1: FPC=2, FCHN=10, C_RT=100, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20
    FPC=3, FCHN=10, C_RT=100, DST_IP=10.40.222.20, NEXT_IP=10.40.222.20
    FPC 2: FPC=1, FCHN=20, C_RT=150, DST_IP=10.40.221.20, NEXT_IP=10.40.221.20
    FPC=3, FCHN=3, C_RT=70, DST_IP=0.0.0.0, NEXT_IP=0.0.0.0 
    NoteFPC 3: None 
    						
    							NDA-24318 CHAPTER 4
    Page 47
    Issue 1
    OPERATION TESTS AFTER INSTALLATION
    CHAPTER 4 OPERATION TESTS AFTER INSTALLATION
    1. GENERAL
    This chapter explains the procedure to verify the normal operation of the IPTRK circuit
    card, when installation and necessary data setting have been completed. This chapter also
    explains the procedures to test and correct possible IPTRK circuit card-related faults.
    2. CCIS NETWORKING VIA IP [C-163]/VOICE OVER IP (H.323)
    When using the H.323 Handler (PA-8IPTB-A) as a signaling interface for Voice over IP (H.323), perform the
    following circuit card operation tests. If necessary, perform fault repairs.
    Caution:Some LSIs on this circuit card may be hot. Handle with care.
    1. Test of OPE lamp on IPTRK circuit card: 
    Note
    Note:
    H.323 Handler (PA-8IPTB-A).
    a.) See if the OPE lamp on the IPTRK circuit card 
    Note is lighting green. This lamp lights if the
    circuit card is operating normally.
    Note:H.323 Handler (PA-8IPTB-A).
    b.) When the OPE lamp is OFF, initialize the circuit card, or perform the insertion/extraction of the
    circuit card once or twice. If the lamp still does not light, replace the circuit card.
    Figure 4-1   Lamps to be Tested (CCIS Networking via IP [C-163])
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    SUBOPE3
    SUBOPE2BUSY
    L3
    L2
    L1
    IP-TXRX
    IP-100M
    F-TXRX
    F-100M F-LRR
    F-LINK
    F-COL
    MODE
    IPCON
    FCON
    MB
    MBR
    Not Used
    Not Used
    Not Used
    Not Used
    OPEIs IPTRK card
    IP-LRR     Is IP network available 
    for connection?
    IP-LINK Is IPTRK-IP network link  
      physically established?
    SUBOPE1Is appropriate data 
     assigned on GK?
    IP-COL
    IPTRK Circuit Card (H.323 Handler/
    (H.323 Handler)
    operating normally?
    PA-8IPTB-A) 
    						
    							CHAPTER 4 NDA-24318
    Page 48
    Issue 1
    OPERATION TESTS AFTER INSTALLATION
    1. Test of IP-LINK lamp on IPTRK circuit card: Note
    Note:
    H.323 Handler (PA-8IPTB-A).
    a.) See if the IP-LINK lamp on the IPTRK circuit card 
    Note is lighting green.
    This lamp will light if the circuit card is physically connected to the IP
    network.
    Note:H.323 Handler (PA-8IPTB-A).
    b.) When the IP-LINK lamp is OFF, make sure that the Ethernet cable is securely
    connected to the IPCON connector. Make sure that neither the Ethernet cable nor the router are
    faulty. If necessary, replace the Ethernet cable.
    2. Test of SUBOPE1 lamp on IPTRK circuit card 
    Note:
    Note:H.323 Handler (PA-8IPTB-A).
    a.) See if the SUBOPE1 lamp on the IPTRK circuit card 
    Note is lighting green. This lamp will light
    when the appropriate data has been assigned on the Gate Keeper (GK) side.
    Note:H.323 Handler (PA-8IPTB-A).
    b.) When the SUBOPE1 lamp is OFF, make sure that the related office data is correctly assigned on
    both the PBX side and the Gate Keeper (GK) side.
    3. Test of IP-LRR lamp on IPTRK circuit card: 
    Note
    Note:
    H.323 Handler (PA-8IPTB-A).
    a.) See if the IP-LRR lamp on the IPTRK circuit card 
    Note is lighting green. This lamp will light if
    the IP network is available for connection establishment.
    Note:H.323 Handler (PA-8IPTB-A).
    b.) When the IP-LRR lamp is OFF, make sure that the related office data was correctly assigned.
    Make sure that each IP address assigned on the AGIP command is correct.
    4. Test of Speech Conditions with Distant Node:
    a.) Perform the connection test to see if speech can be made with the counterparts of the connected
    node.
    b.) If any test result is abnormal, make sure that the related office data was assigned correctly.
    5. Test of System Messages:
    a.) When an IPTRK circuit card 
    Note is installed, the following messages may be created:
    Note:H.323 Handler (PA-8IPTB-A).
    For CCIS Networking via IP [C-163]:
    33-R IP CARD WARNING
    33-S IP CARD FAILURE
    33-T IP CARD RECOVERY
    33-U H.323 INFORMATION NOTICE
    b.) When any of the messages above are created, make sure that the Ethernet cable is securely
    connected to the IPCON connector (on the IPTRK circuit card), or perform the continuity test of
    the cable (voltage and resistance measurement), using a voltmeter. Otherwise, replace the IPTRK
    circuit card or H.323 Handler.
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							NDA-24318 CHAPTER 4
    Page 49
    Issue 1
    OPERATION TESTS AFTER INSTALLATION
    3. FCCS NETWORKING VIA IP [F-36]
    When using the IPTRK circuit card for FCCS Networking via IP [F-36] (Point-to-
    Multipoint Connection), perform the following circuit card operation tests. If necessary,
    perform fault repairs.
    Caution:Some LSIs on this circuit card may be hot. Handle with care.
    1. Test of OPE lamp on IPTRK circuit card:
    a.) See if the OPE lamp on the IPTRK circuit card is lighting green. This lamp will light if the circuit
    card is operating normally.
    b.) When the OPE lamp is OFF, initialize the circuit card, or perform the insertion/extraction of the
    circuit card once or twice. If the lamp still does not light, replace the circuit card.
    2. Test of SUBOPE0 and SUBOPE1 lamps on IPTRK circuit card:
    a.) See if the SUBOPE0 and SUBOPE1 lamps on the IPTRK circuit card are lighting green. Note
    that SUBOPE1 should light if the circuit card is furnished with an optional sub board (PZ-
    8VCTB).
    b.) When either (or both) of the lamps are OFF, initialize the circuit card, or perform the insertion/
    extraction of the circuit card once or twice. Also, if a sub board is in use, make sure the daughter
    board is securely attached to the IPTRK circuit card (main board). If the lamp still does not light,
    replace the circuit card.
    Figure 4-2   Lamps to be Tested (FCCS Networking via IP [F-36] [Point-to-Multipoint Connection])
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    SUBOPE3
    SUBOPE2       BUSY
    L3
    L2
    L1
    IP-TXRX
    IP-100M
    F-TXRX
    F-100M
    F-COL
    MODE
    IPCON
    FCON
    MB
    MBR
    Not Used
    Not Used
    OPEIs IPTRK card operating  
             normally?
    IP-LRR     Is IP network available 
    for connection?
    IP-LINKIs IPTRK-IP network link  
      physically established?
    SUBOPE1Is CPU of sub board 
     operating normally?
    L1Is FCCS network 
    link established?
    SUBOPE0     Is CPU of IPTRK card’s 
    main board operating normally?
    IP-COL
    IPTRK Circuit CardSub Board (PZ-8VCTB)
    F-LRRIs FCCS network available 
    for connection?
    F-LINKIs IPTRK-FCCS network 
    link physically established? 
    						
    							CHAPTER 4 NDA-24318
    Page 50
    Issue 1
    OPERATION TESTS AFTER INSTALLATION
    3. Test of IP-LINK lamp on IPTRK circuit card:
    a.) See if the IP-LINK lamp on the IPTRK circuit card is lighting green. This
    lamp will light if the circuit card is physically connected to the IP network.
    b.) When the IP-LINK lamp is OFF, make sure that the Ethernet cable is securely
    connected to the IPCON connector. Make sure that neither the Ethernet cable
    nor the router are faulty. If necessary, replace the Ethernet cable.
    4. Test of L1 lamp on IPTRK circuit card:
    a.) See if the L1 lamp on the IPTRK circuit card is lighting green. This lamp will light if the FCCS
    network link is established.
    b.) When the L1 lamp is OFF, make sure the office data was correctly assigned. If necessary, replace
    the circuit card.
    5. Test of IP-LRR lamp on IPTRK circuit card:
    a.) See if the IP-LRR lamp on the IPTRK circuit card is lighting green. This lamp will light if the IP
    network is available for connection establishment.
    b.) When the IP-LRR lamp is OFF, make sure that the related office data is correctly assigned. Make
    sure that each IP address assigned on the AGIP command is correct.
    6. Test of F-LINK lamp on IPTRK circuit card:
    a.) See if the F-LINK lamp on the IPTRK circuit card is lighting green. This lamp will light if the
    circuit card is physically connected to the FCCS network. 
    b.) When the F-LINK lamp is OFF, make sure that the Ethernet cable is securely connected to the
    FCON connector. Make sure that neither the Ethernet cable nor the router are faulty. If necessary,
    replace the Ethernet cable.
    7. Test of F-LRR lamp on IPTRK circuit card:
    a.) See if the F-LRR lamp on the IPTRK circuit card is lighting green. This lamp will light if the
    FCCS network is available for connection establishment.
    b.) When the F-LRR lamp is OFF, make sure that the related office data was assigned correctly.
    Make sure that each IP address assigned on the AETH or AGIP command is correct.
    8. Test of Speech Conditions with Distant Nodes:
    a.) Perform the connection tests to see if speech can be made with the counterparts of the connected
    nodes.
    b.) If any test result is abnormal, make sure the related office data was assigned correctly.
    9. Test of System Messages:
    a.) When an IPTRK circuit card is installed, the following messages may be created:
    23-S FCCS FAILURE
    23-T FCCS FAILURE RECOVERED 
    Note
    b.) When any of the messages above are created, make sure that the Ethernet cable is securely
    connected to the IPCON/FCON connector (on the IPTRK circuit card), or perform the continuity
    test of the cable (voltage and resistance measurement), using a voltmeter.
    Note:Although this message is issued soon after performing system/circuit card initialization, it does not
    necessarily mean a result of fault information. In this case, the message generally indicates the placement
    of the IPTRK circuit card in to normal operation mode.