NDA-24234 CHAPTER 3 Page 191 Revision 3.0 INSTALLATION PROCEDURE 2. CABLE RUNNING FROM THE PBX TO THE MAT AND SMDR NAP-200-013 Sheet 6/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR START MAT (Refer to NAP-200-017) Referring to NAP-200-017, connect 68PH S 2 PORTS CA-A and the installation cable (25P). At the PBX side, confirm the connector name on the LPR backplane, then run 68PH S 2 PORTS CA-A up to the connector position. At the MAT side, run RS-232-CA “0” up to the MAT. SMDR (Refer...
Page 222
CHAPTER 3 NDA-24234 Pag e 19 2 Revision 3.0 INSTALLATION PROCEDURE 3. CONNECTIONS AT THE PBX SIDE 4. CABLE TYING AT THE PBX NAP-200-013 Sheet 7/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR START LT Connectors Confirm each connector name on the backplane and the corresponding LT connector, then connect the two. 16PH EX ALM Connect the 16PH EX ALM CA to the EXALM rear connector on the LPR backplane. NCU Connectors Connect the NCU cable to the connector on the front of the PFT card....
Page 223
NDA-24234 CHAPTER 3 Page 193 Revision 3.0 INSTALLATION PROCEDURE Figure 013-3 Example of Cable Tying Using Tie-Wrap NAP-200-013 Sheet 8/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR Backplane LT6 PL O L T3 L T2 LT5LT 4 L T0 L T 1 REAR SIDETIE-WRAP
Page 224
CHAPTER 3 NDA-24234 Pag e 19 4 Revision 3.0 INSTALLATION PROCEDURE 5. TERMINATION OF THE CABLES BETWEEN THE PBX AND THE MDF OR ATTCON ONTO THE CABLE SUPPORT ASSEMBLY NAP-200-013 Sheet 9/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR START Remove of the Cable Support Assembly. Remove the Cable Support Assembly from the BASEU. (See Figure 013-4.) Peel the cable cover Referring to Table 13-1, confirm the cable terminating locations on the Cable Support Assembly. Per the cable terminating...
Page 225
NDA-24234 CHAPTER 3 Page 195 Revision 3.0 INSTALLATION PROCEDURE Figure 013-4 Cable Support Assembly NAP-200-013 Sheet 10/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR AB C D (LPM, TSWM or DUMMY) REAR VIEW(BASEU) CABLE SUPPORT ASSEMBLY FRONT SIDE VIEW (LPM, TSWM or DUMMY)
Page 226
CHAPTER 3 NDA-24234 Pag e 19 6 Revision 3.0 INSTALLATION PROCEDURE Note: For LPM only. NAP-200-013 Sheet 11/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR Table 013-1 Cable Support Assembly BACKPLANE CABLE SUPPORT No.USE REMARKS MODULE CONNECTOR NAME LPRMISCnA, MISCnB Afor I/O Equipment (MAT, Printer, etc.) Spare cable (15 cables) are to be used as Cable Support Assembly extra cables. The number of cables for the whole system is limited to maximum 100. EXALM NoteAfor Alarm...
Page 227
NDA-24234 CHAPTER 3 Page 197 Revision 3.0 INSTALLATION PROCEDURE Figure 013-5 Clamp Winding NAP-200-013 Sheet 12/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR Shield cableApprox. 18 mm (0.72 inch)CLAMP (M-398902)
Page 228
CHAPTER 3 NDA-24234 Pag e 19 8 Revision 3.0 INSTALLATION PROCEDURE Figure 013-6 Termination of Installation Cables NAP-200-013 Sheet 13/13 Cable Running from the PBX to MDF, ATTCON, MAT, and SMDR (FRONT) CABLE CABLE SUPPORT ASSEMBLY CABLE SUPPORT ASSEMBLY CLAMP CABLEPANHEAD SCREW (PL-C, P, B, MS 4X8X3 GF)
Page 229
NDA-24234 CHAPTER 3 Page 199 Revision 3.0 INSTALLATION PROCEDURE This NAP explains the procedures for terminating cables at the MDF. CAUTION:When terminating Cables to the MDF, the line/trunk circuit card should extend about 50 mm (2 inches) from the module and must not contact the backplane connector. NAP-200-014 Sheet 1/1 Termination of Cables on MDF (Wire Accommodation of Each Cable) START Cable trying at the MDF Secure the CHAMP Connector cables, which have been extended to the MDF as per...
Page 230
CHAPTER 3 NDA-24234 Pag e 20 0 Revision 3.0 INSTALLATION PROCEDURE This NAP explains the following work items: NAP-200-015 Sheet 1/30 Cable Termination and Cross Connections from MDF to Peripheral Equipment, C. O. Lines, and Tie Lines MDF C.O. Line/ Tie LineCross Connection of Stations Cross Connection of Trunks (C.O. Lines and Tie Lines) Cross Connections for PFT Cross connection of Alarm Indicating Panel and Cross connections for TAS indicator Cross connections for External Switches Connection...