Page 81
NDA-24288 CHAPTER 4 Page 69 Revision 1.0 AHSY 179 b0 Not usedb1 b2 b3 b4Designation of Guest Access Code b7b6b5b4ACC - CODEb7b6b5b4ACC - CODE 0000 Out of Service 0111 7 0001 1 1000 8 0010 2 1001 9 0011 3 1010 0 0100 4 1011 * 0101 5 1100 # 0110 6 b5 b6 b7 180 00Not used 181 00 Not used 1820 b0Not used b1 Called # printout (Alert Service) 0/1 = No/Yes b2 When a guest station has been called out by Alert Service, if that guest station is Busy, Locked Out, or under...
Page 82
CHAPTER 4 NDA-24288 Page 70 Revision 1.0 AHSY 183 b0Setting of Attendant Console that sets Alert Service 0 Hex: Service can be set from any of the Attendant Consoles 1 - F Hex: Service can be set only from the Attendant Console of the designated Console Number b1 b2 b3 b4 Classifying the call termination indicating keys based on the Language category of the guest at the time an incoming call from the guest station terminated to the Attendant Console. 0/1 = Not Required/Required b5Not used b6 In the...
Page 83
NDA-24288 CHAPTER 4 Page 71 Revision 1.0 AHSY 1850 b0Not used b1 Guest Room Calling - Attendant Console Service 0/1 = Out/In Service 0 b2 Not used 0 b3 0b4 0b5 0b6 0b7 186 b0 Not used b1 b2 b3 b4 b5 b6 b7 Double Suite Room Service 0/1 = Out/In Service 1870 b0Not used 0b1 b2 Processing for the case where there is any busy station among the Suite Room stations generally called by Suite Room Calling - Attendant Console service 0/1 = Sending Busy Tone/Idle Station Calling 0 b3 Not used 0 b4 0b5 0b6 0b7...
Page 84
CHAPTER 4 NDA-24288 Page 72 Revision 1.0 AHSY 188 b0Processing for Suite Room Station/Connecting Room Station Busy b1b0 00: Busy Tone 0 1 : An idle station within the room is called 1 0 : From a station, the call is transferred to the Attendant Console if the caller is not the console operator. b1 0b2Fixed Data 0b3 0b4Not used b5 When a call terminates to the Double Suite Room: 0/1 = All stations ring simultaneously/Alternately between Primary Suite and Secondary Suite 1 b6Fixed Data b7 Suite Room...
Page 85
NDA-24288 CHAPTER 4 Page 73 Revision 1.0 AHSY 191 00 Not used 192 00 Not used 193 00 Not used 194 00 Not used 195 00 Not used 196 00 Not used 197 00 Not used 198 00 Not used 199 00 Not used 200 00 Not used 201 00 Not used 202 00 Not used 203 00 Not used 204 00 Not used 205 00 Not used 206 00 Not used 207 00 Not used 208 00 Not used 209 00 Not used 210 00 Not used 211 00 Not used 212 00 Not used 213 00 Not used 214 00 Not used 215 00 Not used 216 00 Not used 217 00 Not used 218 00 Not used 219 00 Not...
Page 86
CHAPTER 4 NDA-24288 Page 74 Revision 1.0 AHSY 226 00 Not used 227 00 Not used 228 00 Not used 229 00 Not used 230 00 Not used 231 00 Not used 232 00 Not used 233 00 Not used 234 00 Not used 235 00 Not used 236 00 Not used 237 00 Not used 238 00 Not used 239 00 Not used 240 00 Not used 241 00 Not used 242 00 Not used 243 00 Not used 244 00 Not used 245 00 Not used 246 00 Not used 247 00 Not used 248 00 Not used 249 00 Not used 250 00 Not used 251 00 Not used 252 b0 Room Key Information 0/1 = Key Rack...
Page 87
NDA-24288 CHAPTER 4 Page 75 Revision 1.0 AHSY 2580 b0Not used b1 Maid Status - Cleaning Start via Guest Station (Feature Code = 11, Function Code = 1) Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. b2 Maid Status - Cleaning End via Guest Station (Feature Code = 11, Function Code = 2) b3 Maid Status - Inspection End via Guest Station (Feature Code = 11, Function Code = 3) 0 b4 Not used...
Page 88
CHAPTER 4 NDA-24288 Page 76 Revision 1.0 AHSY 2620 b0 Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. 0b1 0b2 b3 Message Waiting Lamp - On (Feature Code = 13, Function Code = 3) b4 Message Waiting Lamp - Off (Feature Code = 13, Function Code = 4) 0 b5 Not used 0b6 0b7 263 00Not used 2640 b0Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of...
Page 89
NDA-24288 CHAPTER 4 Page 77 Revision 1.0 AHSY 2660 b0Not used Sending a Service Feature Text (Information) to PMS. 0/1 = In Service/Out Service When the text is not to be sent to PMS, “1” assigned to the corresponding bit. 0b1 b2 Room Cutoff and Do Not Disturb (Feature Code = 15, Function Code = 2) b3 Not used 0 b4 0b5 0b6 0b7 267 00Not used 2680 b0 Not used 0b1 0b2 0b3 b4 Checkout - C.O. line Outgoing Call Report (Feature Code = 16, Function Code = 5) b5 Checkout - Message Off Report (Feature Code =...
Page 90
CHAPTER 4 NDA-24288 Page 78 Revision 1.0 AHSY 2700 b0Not used Sending a Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. 0b1 b2 Room Data Image - Room Data Report (Feature Code = 17, Function Code = 2) 0 b3Not used b4 Room Data Image - Room Data Exchange (Feature Code = 17, Function Code = 4) 0 b5Not used b6 Room Data Image - Room Data Report (Feature Code = 17, Function Code = 6) 0 b7Not used...