Page 81

NDA-24288 CHAPTER 4
Page 69
Revision 1.0
AHSY
179
b0
Not usedb1
b2
b3
b4Designation of Guest Access Code
b7b6b5b4ACC - CODEb7b6b5b4ACC - CODE
0000 Out of Service 0111 7
0001 1 1000 8
0010 2 1001 9
0011 3 1010 0
0100 4 1011 *
0101 5 1100 #
0110 6
b5
b6
b7
180 00Not used
181 00
Not used
1820
b0Not used
b1
Called # printout (Alert Service)                                    
0/1 = No/Yes
b2
When a guest station has been called out by Alert Service, if that guest station 
is Busy, Locked Out, or under...

Page 82

CHAPTER 4 NDA-24288
Page 70
Revision 1.0
AHSY
183
b0Setting of Attendant Console that sets Alert Service
0 Hex: Service can be set from any of the Attendant Consoles
1 - F Hex: Service can be set only from the Attendant Console of the 
designated Console Number 
b1
b2
b3
b4
Classifying the call termination indicating keys based on the Language 
category of the guest at the time an incoming call from the guest station 
terminated to the Attendant Console.
0/1 = Not Required/Required
b5Not used
b6
In the...

Page 83

NDA-24288 CHAPTER 4
Page 71
Revision 1.0
AHSY
1850
b0Not used
b1
Guest Room Calling - Attendant Console Service
0/1 = Out/In Service
0
b2
Not used 0
b3
0b4
0b5
0b6
0b7
186
b0
Not used
b1
b2
b3
b4
b5
b6
b7
Double Suite Room Service
0/1 = Out/In Service
1870
b0Not used
0b1
b2
Processing for the case where there is any busy station among the Suite Room 
stations generally called by Suite Room Calling - Attendant Console service
0/1 = Sending Busy Tone/Idle Station Calling
0
b3
Not used 0
b4
0b5
0b6
0b7...

Page 84

CHAPTER 4 NDA-24288
Page 72
Revision 1.0
AHSY
188
b0Processing for Suite Room Station/Connecting Room Station Busy
b1b0
00: Busy Tone
0 1 : An idle station within the room is called
1 0 : From a station, the call is transferred to the Attendant Console if the 
caller is not the console operator.
b1
0b2Fixed Data
0b3
0b4Not used
b5
When a call terminates to the Double Suite Room:
0/1 = All stations ring simultaneously/Alternately between Primary Suite and 
Secondary Suite
1
b6Fixed Data
b7
Suite Room...

Page 85

NDA-24288 CHAPTER 4
Page 73
Revision 1.0
AHSY
191 00
Not used
192 00
Not used
193 00
Not used
194 00
Not used
195 00
Not used
196 00
Not used
197 00
Not used
198 00
Not used
199 00
Not used
200 00
Not used
201 00
Not used
202 00
Not used
203 00
Not used
204 00
Not used
205 00
Not used
206 00
Not used
207 00
Not used
208 00
Not used
209 00
Not used
210 00
Not used
211 00
Not used
212 00
Not used
213 00
Not used
214 00
Not used
215 00
Not used
216 00
Not used
217 00
Not used
218 00
Not used
219 00
Not...

Page 86

CHAPTER 4 NDA-24288
Page 74
Revision 1.0
AHSY
226 00
Not used
227 00
Not used
228 00
Not used
229 00
Not used
230 00
Not used
231 00
Not used
232 00
Not used
233 00
Not used
234 00
Not used
235 00
Not used
236 00
Not used
237 00
Not used
238 00
Not used
239 00
Not used
240 00
Not used
241 00
Not used
242 00
Not used
243 00
Not used
244 00
Not used
245 00
Not used
246 00
Not used
247 00
Not used
248 00
Not used
249 00
Not used
250 00
Not used
251 00
Not used
252
b0
Room Key Information
0/1 = Key Rack...

Page 87

NDA-24288 CHAPTER 4
Page 75
Revision 1.0
AHSY
2580
b0Not used
b1
Maid Status - Cleaning Start via Guest Station
(Feature Code = 11, Function Code = 1)
Sending Service Feature 
Text (Information) to PMS
0/1 = In Service/Out 
Service
When the text is not to be 
sent to PMS, “1” is assigned 
to the corresponding bit.
b2
Maid Status - Cleaning End via Guest Station
(Feature Code = 11, Function Code = 2)
b3
Maid Status - Inspection End via Guest Station
(Feature Code = 11, Function Code = 3)
0
b4
Not used...

Page 88

CHAPTER 4 NDA-24288
Page 76
Revision 1.0
AHSY
2620
b0
Not used
Sending Service Feature 
Text (Information) to PMS
0/1 = In Service/Out 
Service
When the text is not to be 
sent to PMS, “1” is assigned 
to the corresponding bit. 0b1
0b2
b3
Message Waiting Lamp - On
(Feature Code = 13, Function Code = 3)
b4
Message Waiting Lamp - Off
(Feature Code = 13, Function Code = 4)
0
b5
Not used 0b6
0b7
263 00Not used
2640
b0Not used
Sending Service Feature 
Text (Information) to PMS
0/1 = In Service/Out of...

Page 89

NDA-24288 CHAPTER 4
Page 77
Revision 1.0
AHSY
2660
b0Not used
Sending a Service Feature 
Text (Information) to PMS.
0/1 = In Service/Out 
Service
When the text is not to be 
sent to PMS, “1” assigned to 
the corresponding bit. 0b1
b2
Room Cutoff and Do Not Disturb
(Feature Code = 15, Function Code = 2)
b3
Not used 0
b4
0b5
0b6
0b7
267 00Not used
2680
b0
Not used 0b1
0b2
0b3
b4
Checkout - C.O. line Outgoing Call Report
(Feature Code = 16, Function Code = 5)
b5
Checkout - Message Off Report
(Feature Code =...

Page 90

CHAPTER 4 NDA-24288
Page 78
Revision 1.0
AHSY
2700
b0Not used
Sending a Service Feature 
Text (Information) to PMS
0/1 = In Service/Out of 
Service
When the text is not to be 
sent to PMS, “1” is assigned 
to the corresponding bit. 0b1
b2
Room Data Image - Room Data Report
(Feature Code = 17, Function Code = 2)
0
b3Not used
b4
Room Data Image - Room Data Exchange
(Feature Code = 17, Function Code = 4)
0
b5Not used
b6
Room Data Image - Room Data Report
(Feature Code = 17, Function Code = 6)
0
b7Not used...