Home > NEC > Communications System > NEC Neax 2400 Imx Fusion Network System Manual

NEC Neax 2400 Imx Fusion Network System Manual

Here you can view all the pages of manual NEC Neax 2400 Imx Fusion Network System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 201

CHAPTER 8 ND-70185 (E)
Page 186
Revision 3.0
EX- FCCS
Data Programming
4.1 Brand-new EX-FCCS Network
To install EX-FCCS network as a brand-new system between two Fusion Groups (when no CCIS data has
been assigned), the overall data programming procedure is as follows.
4.1.1 To Log in to All Nodes in EX-FCCS Network
Assign the following system data for all the nodes in the network. According to the condition of each
node, perform necessary data programming as follows.
STEP 1: ASYD
Assign the Point Code...

Page 202

ND-70185 (E) CHAPTER 8
Page 187
Revision 3.0
EX- FCCS
Data Programming
STEP 2: ARTD
Assign the following three routes for this feature:
 Speech Path Route (Traffic Route)
 Signaling Route
 Dummy Route (Flag Route)
Assign each route data in accordance with the table shown below. Note that data assignment in this table is a
typical example.
The other data than above should be set “0” (default data).
STEP 3: ATRK
Assign the LENs data of the trunks. See Figure 8-8.
Figure 8-8   Port Allocation and Related...

Page 203

CHAPTER 8 ND-70185 (E)
Page 188
Revision 3.0
EX- FCCS
Data Programming
STEP 4: MBTC
Assign IDLE status of trunks by designating Route Number and Trunk Number.
STEP 5: ADPC
Assign the destination PC (Point Code) on RT (for speech path) number basis for all the nodes in the
EX-FCCS network.
STEP 6: ACSC
Assign the location of the CCH in CSCG (Common Channel Signaling Controller Group).
Assign thue location of the CCH using the ACSC command. The following is sample data assignment. In this
sample, PC 3 is...

Page 204

ND-70185 (E) CHAPTER 8
Page 189
Revision 3.0
EX- FCCS
Data Programming
STEP 7: ACIC1
Assign CSCG for Basic/Primary Route. The odd numbered CSCG for Alternate Route assignment.
STEP 8: ACIC2
Assign CICs (Circuit Identification Codes) corresponding to trunk number. Although trunk number
and the CIC may not be identical, the same CIC must be given to one speech line between two nodes
as illustrated in Figure 8-9. Be sure to assign PCs of all the nodes in the EX-FCCS network corre-
sponding to ADPC/ACIC1...

Page 205

CHAPTER 8 ND-70185 (E)
Page 190
Revision 3.0
EX- FCCS
Data Programming
STEP 1: ASYD
Assign the Point Code to all the nodes in the network uniquely as described on Page 163.
STEP 2: ADPCL
Assign the destination PC (Point Code) on LGRT (for speech path) number basis for all the nodes in
the network.
STEP 3: ACSCL
Assign the location of the CCH and FPC of the node which accommodates CCIS trunk in CSCG
(Common Channel Signaling Controller Group) for all the nodes in the network.
 Assign the location of the...

Page 206

ND-70185 (E) CHAPTER 8
Page 191
Revision 3.0
EX- FCCS
Data Programming
STEP 3: AFUGN
Assign EX-FCCS Fusion Group data. Designate Self-FUG Number, Connection FUG Number and
Fusion Point Code (FPC) of the NCN within each FUG. Either of FUG is set as the Center FUG by
checking the “CENTER” parameter.
STEP 4: AEXFN
Assign the EX-FCCS CCH Selection Data by designating all the Fusion Point Code (FPC) and the
Point Code (PC) in the connected Fusion Group.
Note:Confirm whether the data assignment is correctly...

Page 207

CHAPTER 8 ND-70185 (E)
Page 192
Revision 3.0
EX- FCCS
Data Programming
STEP 5: ARNPL
Assign the access code for LCR/LCRS as assigned in ASPAN associated with the logical routes for
each external trunk assigned in ARTD/ARTDN.
STEP 6: AMND
Assign the Maximum Necessary Digit (MND).
Note 1:The MND is the total number of ACC + Telephone Number.
Note 2:Refer to CHAPTER 5, Section 7.1 “Assignment of Access Code for Tandem Connection via FCCS - ACIS“
for more detail data programming related to LCR/LCRS such as...

Page 208

ND-70185 (E) CHAPTER 8
Page 193
Revision 3.0
EX- FCCS
Data Programming
4.2 Upgrading CCIS Network to EX-FCCS Network
This section explains the way to assign the data when upgrading a CCIS Network to an EX-FCCS Network.
Perform the necessary data programming using the following upgrading patterns:
 Upgrading CCIS between FUGs to EX-FCCS Network
 Upgrading CCIS between FUG and IVS
2 system to Enhanced CCIS Network
 Upgrading CCIS between IMX system and IVS
2 systems to Enhanced CCIS Network
4.2.1...

Page 209

CHAPTER 8 ND-70185 (E)
Page 194
Revision 3.0
EX- FCCS
Data Programming
1. To Log-in to All Nodes in EX-FCCS Network
Perform the following data programming at each NCN of all the Fusion Groups.
STEP 1: AFUGN
Assign EX-FCCS Fusion Group data. Designate Self FUG Number, connection FUG Number and
Fusion Point Code of the NCN within each FUG. Either of the FUGs assigned as the Center FUG by
clicking the “CENTER” check box.
STEP 2: AEXFN
Assign the CCH Selection Data by designating all the Fusion Point Code...

Page 210

ND-70185 (E) CHAPTER 8
Page 195
Revision 3.0
EX- FCCS
Data Programming
4.2.2 Upgrading CCIS between FUG and IVS2 System to Enhanced CCIS Network
1. To Log-in to All Nodes in EX-FCCS Network
Assign the following data at the NCN of FUG with Centralized MAT for Fusion.
STEP 1: AFUGN
Assign EX-FCCS Fusion Group data. Designate Self-FUG Number, Connection FUG Number and
Fusion Point Code (FPC) of the NCN within each FUG. Assign the FplUG as the Center by clicking
the check box in the “CENTER” parameter.
STEP...
Start reading NEC Neax 2400 Imx Fusion Network System Manual

Related Manuals for NEC Neax 2400 Imx Fusion Network System Manual

All NEC manuals