Page 201
CHAPTER 8 ND-70185 (E) Page 186 Revision 3.0 EX- FCCS Data Programming 4.1 Brand-new EX-FCCS Network To install EX-FCCS network as a brand-new system between two Fusion Groups (when no CCIS data has been assigned), the overall data programming procedure is as follows. 4.1.1 To Log in to All Nodes in EX-FCCS Network Assign the following system data for all the nodes in the network. According to the condition of each node, perform necessary data programming as follows. STEP 1: ASYD Assign the Point Code...
Page 202
ND-70185 (E) CHAPTER 8 Page 187 Revision 3.0 EX- FCCS Data Programming STEP 2: ARTD Assign the following three routes for this feature: Speech Path Route (Traffic Route) Signaling Route Dummy Route (Flag Route) Assign each route data in accordance with the table shown below. Note that data assignment in this table is a typical example. The other data than above should be set “0” (default data). STEP 3: ATRK Assign the LENs data of the trunks. See Figure 8-8. Figure 8-8 Port Allocation and Related...
Page 203
CHAPTER 8 ND-70185 (E) Page 188 Revision 3.0 EX- FCCS Data Programming STEP 4: MBTC Assign IDLE status of trunks by designating Route Number and Trunk Number. STEP 5: ADPC Assign the destination PC (Point Code) on RT (for speech path) number basis for all the nodes in the EX-FCCS network. STEP 6: ACSC Assign the location of the CCH in CSCG (Common Channel Signaling Controller Group). Assign thue location of the CCH using the ACSC command. The following is sample data assignment. In this sample, PC 3 is...
Page 204
ND-70185 (E) CHAPTER 8 Page 189 Revision 3.0 EX- FCCS Data Programming STEP 7: ACIC1 Assign CSCG for Basic/Primary Route. The odd numbered CSCG for Alternate Route assignment. STEP 8: ACIC2 Assign CICs (Circuit Identification Codes) corresponding to trunk number. Although trunk number and the CIC may not be identical, the same CIC must be given to one speech line between two nodes as illustrated in Figure 8-9. Be sure to assign PCs of all the nodes in the EX-FCCS network corre- sponding to ADPC/ACIC1...
Page 205
CHAPTER 8 ND-70185 (E) Page 190 Revision 3.0 EX- FCCS Data Programming STEP 1: ASYD Assign the Point Code to all the nodes in the network uniquely as described on Page 163. STEP 2: ADPCL Assign the destination PC (Point Code) on LGRT (for speech path) number basis for all the nodes in the network. STEP 3: ACSCL Assign the location of the CCH and FPC of the node which accommodates CCIS trunk in CSCG (Common Channel Signaling Controller Group) for all the nodes in the network. Assign the location of the...
Page 206
ND-70185 (E) CHAPTER 8 Page 191 Revision 3.0 EX- FCCS Data Programming STEP 3: AFUGN Assign EX-FCCS Fusion Group data. Designate Self-FUG Number, Connection FUG Number and Fusion Point Code (FPC) of the NCN within each FUG. Either of FUG is set as the Center FUG by checking the “CENTER” parameter. STEP 4: AEXFN Assign the EX-FCCS CCH Selection Data by designating all the Fusion Point Code (FPC) and the Point Code (PC) in the connected Fusion Group. Note:Confirm whether the data assignment is correctly...
Page 207
CHAPTER 8 ND-70185 (E) Page 192 Revision 3.0 EX- FCCS Data Programming STEP 5: ARNPL Assign the access code for LCR/LCRS as assigned in ASPAN associated with the logical routes for each external trunk assigned in ARTD/ARTDN. STEP 6: AMND Assign the Maximum Necessary Digit (MND). Note 1:The MND is the total number of ACC + Telephone Number. Note 2:Refer to CHAPTER 5, Section 7.1 “Assignment of Access Code for Tandem Connection via FCCS - ACIS“ for more detail data programming related to LCR/LCRS such as...
Page 208
ND-70185 (E) CHAPTER 8 Page 193 Revision 3.0 EX- FCCS Data Programming 4.2 Upgrading CCIS Network to EX-FCCS Network This section explains the way to assign the data when upgrading a CCIS Network to an EX-FCCS Network. Perform the necessary data programming using the following upgrading patterns: Upgrading CCIS between FUGs to EX-FCCS Network Upgrading CCIS between FUG and IVS 2 system to Enhanced CCIS Network Upgrading CCIS between IMX system and IVS 2 systems to Enhanced CCIS Network 4.2.1...
Page 209
CHAPTER 8 ND-70185 (E) Page 194 Revision 3.0 EX- FCCS Data Programming 1. To Log-in to All Nodes in EX-FCCS Network Perform the following data programming at each NCN of all the Fusion Groups. STEP 1: AFUGN Assign EX-FCCS Fusion Group data. Designate Self FUG Number, connection FUG Number and Fusion Point Code of the NCN within each FUG. Either of the FUGs assigned as the Center FUG by clicking the “CENTER” check box. STEP 2: AEXFN Assign the CCH Selection Data by designating all the Fusion Point Code...
Page 210
ND-70185 (E) CHAPTER 8 Page 195 Revision 3.0 EX- FCCS Data Programming 4.2.2 Upgrading CCIS between FUG and IVS2 System to Enhanced CCIS Network 1. To Log-in to All Nodes in EX-FCCS Network Assign the following data at the NCN of FUG with Centralized MAT for Fusion. STEP 1: AFUGN Assign EX-FCCS Fusion Group data. Designate Self-FUG Number, Connection FUG Number and Fusion Point Code (FPC) of the NCN within each FUG. Assign the FplUG as the Center by clicking the check box in the “CENTER” parameter. STEP...