CHAPTER 6 ND-70185 (E) Page 146 Revision 3.0 POST INSTALLATION TEST SDT Card Loopback Test STEP 2: Make sure that the “LPB” lamp on the PA-SDTA card, or the “SYCxx” lamp on the PA-SDTB card lights steady-green. STEP 2.5: When the loopback pattern is “local loopback,” confirm that the “OPT” and “SYNC” lamps are both OFF on the PA-SDTA card. (“OPT” and “SYNC” lamps are OFF = Result of loopback test is fine) STEP 3: Return the key settings of the P-SW key (on PA-SDTA card: see Figure 6-15) to the original...
Page 162
ND-70185 (E) CHAPTER 7 Page 147 Revision 3.0 CHAPTER 7 TROUBLESHOOTING This chapter explains the Fusion-related system messages that may be displayed, together with procedures on how to repair the indicated failure. If the message is displayed, follow the procedure described in each system message. For more information on the other system messages, see the NEAX2400 IMX System Operations and Maintenance Manual. 1. List of Fusion-related System Messages Table 7-1 List of Fusion-related System Messages No....
Page 163
CHAPTER 7 ND-70185 (E) Page 148 Revision 3.0 TROUBLESHOOTING List of Fusion-related System Messages Figure 7-1 shows a sample system configuration. The number of cards and cables may vary depending on the system. Figure 7-1 Related Hardware : 10 BASE-T cable : Front Cable 06 04 05 03 02 01 0006 04 05 03 02 01 00 CN CNCN CN CN CN BASEU PIM 1 PIM 0 LPMTOPU BSCM CN CN CN FCH DTI HUB FCHDTI13-H Signaling Link Failure 1. 0001 0000 0000 0000 2. 0000 0000 0000 0000 MAT FRONT VIEW This figure shows an...
Page 164
ND-70185 (E) CHAPTER 7 Page 149 Revision 3.0 TROUBLESHOOTING 3-B PM C-level Infinite Loop (Permanent) 2. 3-B PM C-level Infinite Loop (Permanent) This message is displayed when a C-level program abnormal state has been detected as permanent. When the abnormal state is detected by the Port Microprocessor (PM) on an FCH card, the PM places the card into make-busy status. If the failure occurs more than 15 times an hour, the system judges the failure as permanent, issuing 3-B system message. Figure 7-2...
Page 165
CHAPTER 7 ND-70185 (E) Page 150 Revision 3.0 TROUBLESHOOTING 3-B PM C-level Infinite Loop (Permanent) Figure 7-4 How to Replace the FCH (PA-FCHA) Card [How to Replace FCH card] 4C026AE 8 MNT 3 MNT 3MNT 3MB MBMB Not Used MBR FCH (PA-FCHA) FCHDTI MBR key operation Cable Disconnection Anti-static Kit OPE OPE ATTENTIONContents Static Sensitive Handling Precautions Required (MNT 3) 0 12MNT Front Cable MB key operation FCHDTI FCHDTI 1) Provide the anti-static kit. 2) Turn ON the MNT 3 switch....
Page 166
ND-70185 (E) CHAPTER 7 Page 151 Revision 3.0 TROUBLESHOOTING 3-C PM C-level Infinite Loop (Temporary) 3. 3-C PM C-level Infinite Loop (Temporary) This message is displayed when the C-level program has been detected as abnormal by the Port Micropro- cessor (PM) mounted on the FCH (PA-FCHA) card. In this instance, the system performs an appropriate restart (B-monitor/Initial restart) according to the frequency of the failures. If the frequency exceeds 15 times an hour, it is judged as permanent. See 3-B PM...
Page 167
CHAPTER 7 ND-70185 (E) Page 152 Revision 3.0 TROUBLESHOOTING 3-E PM Lockup Failure (Temporary) 4.1 Repair Procedure STEP 1: Make sure that station-to-station connections can be established in the PIM containing the indicated FCH (PA-FCHA) card. If the station-to-station connections cannot be established, the PIM is faulty. Repair the PIM. Other- wise, move to STEP 2. STEP 2: Initialize the FCH card using the MB key. See Figure 7-3 “How to Initialize FCH (PA-FCHA) Card.” When the LED lights green and no...
Page 168
ND-70185 (E) CHAPTER 7 Page 153 Revision 3.0 TROUBLESHOOTING 13-H/I/J Signaling Link Failure (Permanent)/(Temporary)/(Recovery) 6. 13-H/I/J Signaling Link Failure (Permanent)/(Temporary)/(Recovery) This message is displayed when the Fusion link (D-ch) has a failure. If the failure occurs frequently, the system displays 13-H Signaling Link Failure (Permanent). The shaded area in the figure listed below is related to this message. Figure 7-8 Fusion Link (Signaling Link) Failure Figure 7-9...
Page 169
CHAPTER 7 ND-70185 (E) Page 154 Revision 3.0 TROUBLESHOOTING 13-H/I/J Signaling Link Failure (Permanent)/(Temporary)/(Recovery) 6.1 Repair Procedure 13-H (Permanent) STEP 1: Make sure that the front cable is securely inserted. See Figure 7-10 below. Figure 7-10 FCH-DTI Connection STEP 2: Initialize the indicated FCH (PA-FCHA) card using the MB key. (MB key: Down➔ Up ➔ Down) See Figure 7-3. When the LED on the FCH card lights green and the related system messages are not displayed anymore, monitor the...
Page 170
ND-70185 (E) CHAPTER 7 Page 155 Revision 3.0 TROUBLESHOOTING 23-S FCH Failure Notification (Detection) 6.2 Repair Procedure 13-I (Temporary) STEP 1: Make sure that the front cable is securely inserted. (See Figure 7-10.) STEP 2: If this message has been displayed once or twice, monitor the failure for a while. Otherwise, move to STEP 3. STEP 3: If 13-J (Recovery) has been displayed after this message, monitor the failure for a while. Otherwise, move to STEP 4. STEP 4: Initialize the indicated FCH...