Page 31

ND-70684 (E) CHAPTER 3
Page 23
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
2.1 Example of Data Programming for DSS/BLF
2.1.1 ASDT
Note:
*0 = Even-numbered LEN level / **1 = Odd-numbered LEN level
TENANT
NUMBER
(TN) 
1-63STATION
NUMBER
 (STN) 
Max. 5 DigitsLINE EQUIPMENT 
NUMBER 
(LENS)TELEPHONE 
EQUIPMENT 
CLASS
(TEC)
1-31ROUTE 
RESTRICTION
CLASS 
(RSC)
0-15SERVICE 
FEATURE 
CLASS
(SFC) 
0-15REMARKS
MG U G LV
X
200 0 0 0 1 0 *0 12××
For DSS/BLF
201 0 0 0 1 0 **1 12××
For DSS/BLF...

Page 32

CHAPTER 3 ND-70684 (E)
Page 24
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
2.1.2 AKYD
The following table shows DSS key assignment for even-numbered LV (2n). 
MY LINE
TENANT
NUMBER
(TN)STATION
NUMBER
 (STN)
X200
PRIORITY 
FOR 
ANSWERING CALL 
(PRI)
0 - 4PRIME LINE
ALLOW 
OG FROM 
PRIME 
LINE
(S)
0/1MESSAGE 
WAITING 
DATA  
DISPLAY 
SELECTION 
(MWD)
0/1LINE 
PREFERENCE
(LN PRE)
0/1LINE 
PREFERENCE
FOR
SPEAKER
 BUTTON
(SPK)
0 - 3LINE 
PREFERENCE 
FOR ANSWER 
BUTTON
(ANS)
0 - 2LINE...

Page 33

ND-70684 (E) CHAPTER 3
Page 25
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
MY LINE
TENANT
NUMBER
(TN)STATION
NUMBER
 (STN)
X200
PRIORITY 
FOR 
ANSWERING CALL 
(PRI)
0 - 4PRIME LINE
ALLOW 
OG FROM 
PRIME 
LINE
(S)
0/1MESSAGE 
WAITING 
DATA 
DISPLAY 
SELECTION 
(MWD)
0/1LINE 
PREFERENCE
(LN PRE)LINE 
PREFERENCE
FOR
SPEAKER
 BUTTON
(SPK)
0 - 3LINE 
PREFERENCE 
FOR ANSWER 
BUTTON
(ANS)
0 - 2LINE
PREFERENCE 
FOR 
OUTGOING 
BUTTON
(ORG)
0/1TYPE OF 
D
term
(TP)
0 -3 TENANT 
NUMBER
(PL...

Page 34

CHAPTER 3 ND-70684 (E)
Page 26
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
The following table shows DSS key assignment for odd-numbered LV (2n + 1)
MY LINE
TENANT
NUMBER
(TN)STATION
NUMBER
 (STN)
X201
PRIORITY 
FOR
ANSWERING CALL 
(PRI)
0 - 4PRIME LINE
ALLOW 
OG FROM 
PRIME 
LINE
(S)
0/1MESSAGE 
WAITING 
DATA 
DISPLAY 
SELECTION 
(MWD)
0/1LINE 
PREFERENCE
(LN PRE)
0/1LINE 
PREFERENCE
FOR
SPEAKER
 BUTTON
(SPK)
0 - 3LINE 
PREFERENCE 
FOR ANSWER 
BUTTON
(ANS)
0 - 2LINE
PREFERENCE...

Page 35

ND-70684 (E) CHAPTER 3
Page 27
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
MY LINE
TENANT
NUMBER
(TN)STATION
NUMBER
 (STN)
X200
PRIORITY 
FOR 
ANSWERING CALL 
(PRI)
0 - 4PRIME LINE
ALLOW 
OG FROM 
PRIME 
LINE
(S)
0/1MESSAGE 
WAITING 
DATA 
DISPLAY 
SELECTION 
(MWD)
0/1LINE 
PREFERENCE
(LN PRE)LINE 
PREFERENCE
FOR
SPEAKER
 BUTTON
(SPK)
0 - 3LINE 
PREFERENCE 
FOR ANSWER 
BUTTON
(ANS)
0 - 2LINE
PREFERENCE 
FOR 
OUTGOING 
BUTTON
(ORG)
0/1TYPE OF 
D
term
(TP)
0 -3 TENANT 
NUMBER
(PL...

Page 36

CHAPTER 3 ND-70684 (E)
Page 28
Revision 1.0
DATA PROGRAMMING
Add-On Module
3. Add-On Module
This section covers how to assign an Add-On Module. In Figure 3-3, an Add-On Module and the associated
D
term are assigned as follows:
 
Figure 3-3   Example of Data Programming for Add-On Module
TERMINAL LINE EQUIPMENT NUMBER (LEN) STATION NUMBER (ST)
Add-On Module 000101201  
Note
D
term000100 200
2n+1
2nLV 
7 
6 
5 
4 
3 
2 
1 
0 ELC
Note:Station number 201 is only used to assign Line/Feature access keys for...

Page 37

ND-70684 (E) CHAPTER 3
Page 29
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure for Add-On Module
4. Data Programming Procedure for Add-On Module
When assigning Add-On Module data, perform the following procedure. “X” indicates the value should be tai-
lored to the existing system.
STEP 1: ASDT
Assign a D
term to an even-numbered LEN level. (In this example, LV 0 is used.) Assign the Add-On
Module to the subsequent odd-numbered LEN level. (In this example LV 1 is used.)
STEP 2: AKYD
Assign...

Page 38

CHAPTER 3 ND-70684 (E)
Page 30
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure for Add-On Module
Use the Add-On Module port to assign key information for the last 36 keys on the ADM.
TN : X
STN : 201
TP : 1 Buttons 1-39 are assignable
PRI : 0
PL TN : X
PL STN : 200 Enter the associated D
term as a PL STN
S : 0 = Off Hook Suppression is off
MWD : X
LN PRE : 0 = Prime Line Pickup
KYN : 5-40 Corresponds to KYNs 25-60 on the Add-On Module
KYI : X
KD : X
TN : X
STN : XXXX
RG : X
ICM : X
G-ID : X 

Page 39

ND-70684 (E) CHAPTER 3
Page 31
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure for Add-On Module
Figure 3-4   DSS Key Assignment for Add-On Module
000504030201
545958575655
485352515049
424746454443
364140393837
303534333231
242928272625
182322212019
121716151413
061110090807
Use KYNs 5-40 of the Add-On Module for programming the remaining 36 Line/Feature access keys on the Add-
On Module.Use KYNs 17-40 of the associated D
term for programming the first 24 Line/Feature access keys on the Add-On...

Page 40

CHAPTER 3 ND-70684 (E)
Page 32
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure for Add-On Module
4.1 Example of Data Programming for Add-On Module
4.1.1 ASDT
Note:
*0 = Even numbered LEN level / **1 = Odd numbered LEN level
4.1.2 AKYD
For Line/Feature access keys: KYNs 1 - 24  (Dterm)
TENANT 
NUMBER 
(TN) 
1-63STATION 
NUMBER 
(STN) 
Max. 5 DigitsLINE EQUIPMENT NUMBER
(LENS)TELEPHONE 
EQUIPMENT 
CLASS 
(TEC)
1-31ROUTE 
RESTRICTION 
CLASS
 (RSC)
0-15SERVICE  
FEATURE 
CLASS 
(SFC) 
0-15REMARKS
MG...