ND-70684 (E) CHAPTER 1
Page 13
Revision 1.0
OVERVIEW
Add-On Module
The following Line/Feature keys must be assigned for KYNs 1 through 24:
 MESSAGE REMINDER (FKY = 6)
 My Line and/or Prime Line of the master D
term.
KYNs 49 through 60 cannot be assigned for line features. (I-USE INDICATION, I-HOLD INDICATION can
not be used since these keys are not equipped with LEDs.)
To assign Speed Calling-One Touch (FKY = 49), use KYNs 1 through 16 and 25 through 52, since the memory
area is retained for these KYNs...

Page 22

CHAPTER 1 ND-70684 (E)
Page 14
Revision 1.0
This page is for your notes. 

Page 23

ND-70684 (E) CHAPTER 2
Page 15
Revision 1.0
CHAPTER 2 INSTALLATION PROCEDURE
This chapter describes the installation procedure for the DSS console. It includes a connection diagram and the
locations of the cable leads. 
1. Connection Diagram for DSS/BLF
When the DSS console is used as a DSS/BLF, connect the associated cables referring to Figure 2-1.
Figure 2-1   Connection Diagram for the DSS/BLF
Note 1:For more detailed information on the DAU, see the NEAX2400 IMX DAU System Manual.
Note 2:These leads...

Page 24

CHAPTER 2 ND-70684 (E)
Page 16
Revision 1.0
INSTALLATION PROCEDURE
Connection Diagram for the Add-On Module
2. Connection Diagram for the Add-On Module
When the DSS console is used as an Add-On Module, connect the associated cables referring to Figure 2-2.
Figure 2-2   Connection Diagram for the Add-On Module
Note 1:For more detailed information on the DAU, see the NEAX2400 IMX DAU System Manual.
Note 2:These leads are not used for this system.
PIM
ELC Connection Diagram
PIM
MDF
TA
TB
RA
RBRA TB TA
RB...

Page 25

ND-70684 (E) CHAPTER 2
Page 17
Revision 1.0
INSTALLATION PROCEDURE
Cable Lead Location
3. Cable Lead Location
The leads appear as shown below. Figure 2-3 illustrates an example of cable lead locations. For more detailed
information on each card, see the NEAX2400 IMX Circuit Card Manual and/or the NEAX2400 IMX DAU Sys-
tem Manual.
Figure 2-3   Example of Cable Lead Location
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
501
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22...

Page 26

CHAPTER 2 ND-70684 (E)
Page 18
Revision 1.0
This page is for your notes. 

Page 27

ND-70684 (E) CHAPTER 3
Page 19
Revision 1.0
CHAPTER 3 DATA PROGRAMMING
This chapter describes how to program office data associated with the DSS.
1. DSS/BLF
This section covers how to assign Office Data for a DSS/BLF. A sample data assignment is shown in Figure 3-
1. In this example the DSS/BLF and the D
term are assigned as follows:
Figure 3-1   Example of Data Programming for DSS/BLF
TERMINAL LINE EQUIPMENT NUMBER (LEN) STATION NUMBER (STN)
DSS/BLF 000100 200 - 201 Note
D
term000107 400
2n+1
2n
LV  
7...

Page 28

CHAPTER 3 ND-70684 (E)
Page 20
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
2. Data Programming Procedure (DSS/BLF)
When assigning DSS/BLF data, perform the following procedure. “X” indicates the value should be tailored to
the existing system.
STEP 1: ASYD
Assign the DSS/BLF to an even-numbered LEN level. (In this example LV 0 is used.)
Assign a station to be used for programming DSS keys (KYNs 31-60) to the subsequent LENS. (In
this example, LV 1 is used.
STEP 2: AKYD
Assign key...

Page 29

ND-70684 (E) CHAPTER 3
Page 21
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
KYN 2 must be programmed as the associated Dterm station.
Assign desired station numbers to the corresponding DSS keys on the console. In this instance, KYNs
10-39 are used. The upper and lower 30 keys are associated with even-numbered ports and odd-num-
bered ports as shown below.KYN : 2
KY1 : 2 = Multi Line
KD : 0 = Line
TN : X
STN : 400 Associated D
term
RG : X
KYN : 1 0-39
KY1 : 2 = Multi Line
KD : 2 For...

Page 30

CHAPTER 3 ND-70684 (E)
Page 22
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure (DSS/BLF)
Figure 3-2   DSS Key Assignment for DSS/BLF
000504030201
545958575655
485352515049
424746454443
364140393837
303534333231
242928272625
182322212019
121716151413
061110090807
Use KYNs 10-39 of an even-numbered LEN level (0, 2, 4, 6)
for programming the upper 30 DSS keys on the DSS/BLF
Use KYNs 10-39 of an odd-numbered LEN level (1, 3, 5, 7)
for programming the lower 30 DSS keys on the DSS/BLF 
Start reading NEC Neax 2400 Imx Direct Station Selection Console Manual

Related Manuals for NEC Neax 2400 Imx Direct Station Selection Console Manual